From the Fuel Level Probe "Black Box":
Hook up the Green Wire to the Stratomaster Fuel Level Input on the RDVAC, the
Red Wire to +12V, and the Black Wire to Ground.
The programming in the Stratomaster Unit makes you put 1.3 Gallons in the tank,
which it then will interpret as your empty level. This gives you a reserve of fuel
and additional safety measure of fuel when Stratomaster is reading empty. We
Started with an empty fuel tank and added 2 gallons of fuel and set Fuel Tank
capacity at 1.3 Gallons by hitting "Select" with the Current Output Reading (for
us, this reading was 1920 Ohms). We then set our "fuel low" alarm at 2.0
Gallons, which gives us more than a 1/2 hour reserve once the alarm goes off.
Follow the Instructions on Page 55 of your manual to calibrate your sensor.
Our calibration used the following Resistive Outputs:
0.0 Gallons (1.3 Gallons) 1920 Ohms
2.9 Gallons 1869 Ohms
5.8 Gallons 1804 Ohms
8.9 Gallons 1757 Ohms
11.8 Gallons 1703 Ohms
15.06 Gallons 1651 Ohms