Modem User Manual

LZT 123 1834 47
5.8 Powering the Module ON and OFF (ON/OFF)
Pin Name Direction Function
14 ON/OFF Input Device on/off control
5.8.1 Turning the Module On
Figure 5.8-1 Power On timing
The GR64 power ON sequence is shown above. The significant signals are VCC,
ON/OFF and VREF, shown by solid lines. The other signals (in dashed lines) are
internal to the module and are shown for reference purposes only.
Initially, power is supplied to the VCC pins. The presence of power raises the
ON/OFF through a pull-up resistor to VCC potential. In order to power the module,
ON/OFF is pulled to ground. Once ON/OFF has been held low for 125ms (denoted by
t
1
) the primary LDOs power up; the VREF signal comes from one of the primary LDOs.
For module variants where VREF supplies a reference voltage to the host, it acts as a
useful indicator that the baseband is powered.
When the VREF is configured as an input, it cannot be used as a power
indicator.
NOTE