ROUTING SWITCHER SYSTEM ROUTING SWITCHER RS-422A REMOTE ROUTING SWITCHER DVS-128 DVS-RS1616 DVS-A3232 DVS-TC3232 DVS-V1616 BVS-A3232 HDS-V3232 BVS-V3232 DVS-V3232B/V3232M DVS-V6464B/V6464M HDS-X3400/X3600/X3700 DIGITAL AUDIO ROUTING SWITCHER TIME CODE ROUTING SWITCHER DIGITAL VIDEO ROUTING SWITCHER ANALOG AUDIO ROUTING SWITCHER HD ROUTING SWITCHER ANALOG VIDEO ROUTING SWITCHER DIGITAL VIDEO ROUTING SWITCHER MULTI BIT RATE ROUTING SWITCHER 16-SOURCE CONTROL UNIT MULTI DISPLAY CONTROL UNIT BKS-R16
IBM and AT are registered trademarks of International Business Machines, Inc. Windows is a registered trademark of Microsoft Corporation. Windows NT is a trademark of Microsoft Corporation. Intel 80486SX is a trademark of Intel Corporation.
Table of Contents Manual Structure Purpose of this manual .............................................................................................. 5 Contents ..................................................................................................................... 5 Related manuals ......................................................................................................... 6 DVS-128/HDS-X3000 Series and DVS-V3232M/V6464M ..................................... 8 1.
3. Control Terminal 3-1. 3-2. 3-3. 3-4. 3-5. Selecting the Control Terminal ................................................................... 3-1 Control Terminal Display ........................................................................... 3-2 System Status Screen .................................................................................. 3-3 Menu Screen ................................................................................................ 3-4 3-4-1.
-2. 5-3. 5-4. ROUTING SWITCHER SYSTEM (E) T : SET CLOCK .................................................................................... 5-20 U : SELECT REMOTE .......................................................................... 5-21 V : SELECT WARNING DISPLAY ..................................................... 5-22 W : SYSTEM STATUS LOG ................................................................. 5-23 X : DISPLAY S-BUS COMMUNICATION .........................................
5-5. 5-6. 5-7. 5-8. Z : SET PANEL STATUS (BKS-R1607/R1608/R3204/R3205/R3209/R3210) ...................................................................... 5-52 Backup of Setting Data ............................................................................. 5-54 When Data is Lost ..................................................................................... 5-54 Initialization of Table Data ....................................................................... 5-55 5-7-1.
Manual Structure Purpose of this manual This is the Installation Manual (software) for the Sony routing switcher system (it is described as “router system” in this manual). It contains information on the initial settings of the software when installing the units making up the digital router system. This manual is intended for system and service engineers. But operators can also refer to it when setting and changing the system. This manual is supplied with the following switchers.
Related manuals In addition to this installation manual for system setup, the following manuals are also available for the main units making up the system. (1) DVS-V3232B/V6464B/V3232M/V6464M/128 . Operation Manual (supplied with the DVS-V3232B/V6464B/V3232M/V6464M/128) This manual explains the notes on operating, specifications, locations and functions. .
(2) DVS-V1616/A3232/RS1616/TC3232, BVS-V3232/A3232, BKS-R1607/ R1608/R3209/R3210 . Operation Manual (supplied with each unit) This manual explains the notes on operating, specifications, locations and functions of each unit. . Maintenance Manual (supplied with each unit) This manual contains information on the installation, maintenance, and servicing of the unit and its parts (replacement, block diagram, adjustment, board layout, schematic diagram, detailed parts list and so on).
(6) HDS-X3400/X3600/X3700 . Maintenance Manual Part 1 (supplied with HDS-X3000 series) This manual describes how to install and maintain the HDS-X3000 series, and contains information on primary services (how to replace the main blocks and boards, and other information). . Maintenance Manual Part 2 (available on request) This manual describes the information that premises the service board parts replacement (board layouts, schematic diagrams and detailed parts list) of the HDS-X3000 series.
Section 1 System Overview 1-1. Digital Routing Switcher System The system consists of the following units. . Routing Switcher (DVS-V1616/V3232B/V6464B/A3232/TC3232/RS1616, BVS-V3232/A3232, HDS-V3232) It switches signals according to the command from the remote control unit. Varied switchers are available for different types of signals used (serial digital video, digital audio, time code, RS-422A, etc.) .
1-1. Digital Routing Switcher System Software Versions This manual is intended for systems consisting mainly of the DVS-V3232B/V6464B digital video routing switchers and units loading the following software versions and above. When units other than these are used, some terminal displays will be different and some functions cannot be used. Therefore, please contact to Sony’s service organization to upgrade the version of your software.
1-2. System Control 1-2. System Control 1-2-1. Specifications and functions of control port The DVS-V3232B/V6464B and HDS-V3232 digital video routing switcher is equipped with four kinds of remote ports REMOTE 1 (S-BUS), REMOTE 2 (9-pin), REMOTE 3 (25-pin), and REMOTE 4 (monitor S-BUS). Other switchers are equipped with three kinds of remote ports excluding REMOTE 4. The specifications and functions of the control ports are as follows.
1-2. System Control REMOTE 3 D-sub 25-pin (MODEM side pin arrangement) Protocol RS-232C, 9600 bps*1, 8bit, No Parity, No check Function With this port the communication between the primary station and the control terminal and the setting of the units are performed. It is recommended that the control terminal be always connected to the switcher set to the primary station, so that you can see error message of the communication circuit and operation condition of units.
1-2. System Control 1-2-2. S-BUS control The S-BUS control is a remote control system. It has a simple connection structure and provides highly efficient communication. Multiple routing switchers and remote control units are connected to a single bus line to form a control network called the S-BUS data link.
1-2. System Control Example of S-BUS control system connection : S-BUS : Signal Line Control Terminal : RS-232C : T Bridge (A) : T Bridge (B) Personal computer with a communication software or Windows 3.
1-2. System Control 1-2-3. 9-pin remote control The Sony digital routing switcher can be controlled from external control units connected to the REMOTE 2 (D-sub 9-pin) using RS-422A. For DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232, the functions performed by 9-pin remote control, can especially be upgraded to a great extent. The following three kinds of 9-pin remote protocols can be used. . Sony production switcher protocol . Sony audio mixer protocol .
1-2. System Control The following is an example of a 9-pin remote control connection.
1-2. System Control 1-2-4. Connection of control terminal Connect the control terminal to the REMOTE3 (D-sub 25-pin) connector of the primary station as shown below. The control terminal is used for setting of the router system and for displaying the information of errors, problems, system status, etc. during operation. Use the personal computer installing the terminal software as the control terminal of the router system.
1-2. System Control The following shows one way of connecting the monitor S-BUS system. Secondary Station (S) Primary Station (M) B type DVS-V6464B A type DVS-V6464B (Max. 200 m) (Inut signal) (Max. 200 m) Secondary Station (S) DVS-V6464B D type Secondary Station (S) Monitor C type DVS-V6464B (Max. 200 m) (Output/Input signal) (Max. 200 m) Monitor BKS-R3209 (M) (S) : M/S switch setting on the monitor Board.
Section 2 Functions 2-1. Main Functions of Router System * * * * * * * 1) The routing switcher is equipped with a system controller. It therefore does not require an additional controller for controlling the routing switchers. 2) By the cascade connection, up to 512 x 512 crosspoints can be selected. 3) Up to 8 levels can be assigned. 4) Up to 254 units can be controlled in a system. 5) Each output signal can be protected so that they will not be switched by other control units.
2-2. Built-in Controller 2-3. Matrix Sizes 2-4. Number of Levels 2-5. Number of Units 2-2. Built-in Controller The Sony digital routing switcher incorporates a system controller and therefore does not require a separate external controller. When several routing switchers are connected to the S-BUS, the CPU of the switcher set as the primary station will control the whole system. 2-3. Matrix Sizes By the cascade connection, input and output signals can be expanded to form a large-scale of router system.
2-6. Protect Function 2-7. Secret Function 2-8. Crosspoint Disable Setting Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-9. Password Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-6. Protect Function Function which protects the crosspoint set so that it cannot be released using other remote control units. While the protect function is on, the destination of the crosspoint to be protected will be fixed.
2-10. Setting the Input/Output Name (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-10. Setting the Input/Output Name (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) The following names can be used for the input/output connectors of the routing switcher. 1. “Type+Number” name 2. ”Description“ name There are altogether three kinds of numbers that can be set as input/output numbers. These are “physical number”, “connector number”, and “virtual number”.
2-10. Setting the Input/Output Name (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) The name “Type + Num” consists of four alphabets and three numbers. It is assigned to the virtual number. Sixteen kinds of letters can be set for the “Type” part. Number 1 to 999 can be used for the “Num” part. Examples: CAM 234, VTR 145 The name “Description” consists of any 16 characters and is assigned to the virtual number, e.g. “Tokyo” and “Market”. Up to 1024 kinds of names can be registered.
2-11. Virtual Mapping Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-11. Virtual Mapping Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) Several routing switchers can be mapped on a virtual matrix with 512 inputs and 512 outputs in router system. The matrix of one switcher can be also divided into several virtual levels and mapped. For example, a switcher handling the 4:2:2 video signal and a switcher handling the 4 fsc video signal can be mapped on the same level.
2-12. Free Assignment Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-12. Free Assignment Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) While the same input/output number can be assigned, through levels 1 to 8, for each input/output name, different physical number can also be assigned on each level for an input/output name. The following figure shows the case that DVS-V6464B is used for level 1 and DVS-A3232 for levels 2 and 3.
2-13. Monitor Function (BKDS-V3292B only) 2-13. Monitor Function (BKDS-V3292B only) If a DVS-V3232B/V6464B is equipped with the optional BKDS-V3292B, any input/output signal can be monitored. The input and output signals can be observed on different monitors or on the same monitor by switching channels. By connecting the monitor signals of several switchers in cascade form, all input and output signals can be observed on one monitor.
2-13.
2-14. Tie Line Management (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-14. Tie Line Management (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) If the primary station is a DVS-V3232B/V6464B, BKPF-R70 or HDS-V3232, by previously setting four signal paths between routing switchers, unused signal paths can be selected automatically and protected when input and output names are selected. This function is called tie line management.
2-14. Tie Line Management (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) Operation example: 1. IN023 and OUT027 are selected from the remote control unit. 2. The CPU of the primary station detects IN023 from the source group. In the example below, the corresponding group is S002. 3. Like for IN023, the CPU also detects OUT027. The corresponding group is D002. 4. The CPU of a primary station detects the path which has the S002 and D002 groups.
2-16. Self-Diagnosis Function 2-16. Self-Diagnosis Function The routing switcher performed self-diagnosis on the following items and displays the results on the control terminal connected to the primary station. O Presence of board and its sort O Version of ROM on the control board O Presence of backup power supply unit/backup CPU board O Detection of fan rotation O Display of reference signal O Display of errors as follows . Faulty crosspoint (hardware) . Display of high temperature .
2-17. Route Function 2-17. Route Function One of an application of Router is to expand number of Source inputs for DVS-7000 connecting with DVS-V6464B, show below. Route function is to display a source input chasing from a last program out even performing 4 times Reentry function with DVS-7000/DME. To display the actually selected source name, you must set the route function with the control terminal.
2-18. Enhanced Restriction of Selected Block (BKS-R1607/R3210 only) 2-18. Enhanced Restriction of Selected Block (BKS-R1607/R3210 only) If you define a certain number of outputs, you can vary a number of inputs which would not be capable with the older panel. This is applicable with BKS-R1607 and BKS-R3210. Maximum 8 blocks can be defined.
Section 3 Control Terminal 3-1. Selecting the Control Terminal Load Windows 3.1 to an IBM PC/AT compatible machine (CPU: 80486 or a faster and more powerful micro-processor, clock: 25 MHz or faster enough) and use it as a control terminal in the terminal mode of Windows. When using personal computers, codes F1 to F5 must be set to the Windows screen.
3-2. Control Terminal Display 3-2. Control Terminal Display The control terminal display consists of the following three types of screen. . System status screen : It displays messages while the router system is operating. . Menu screen : It displays the menu for setting the router system. . Setting screen : It displays the setting items of each menu.
3-3. System Status Screen 3-3. System Status Screen When the primary station is turned ON, the results of the self-diagnosis and ROM check sum value are displayed as shown below. If the result of the self-diagnosis is satisfactory, “OK” will be displayed at the corresponding item. However if an error has been detected, this item will be the reversal characters.
3-4. Menu Screen 3-4. Menu Screen 3-4-1. Menu screen of the primary station The menu screen shows all menu items for system setting in the table data of the primary station. By selecting the items on the menu screen using the following procedure, the screen will show the setting screen. n Compared with the system status screen, router system operations take more time, when the menu screen or the setting screen is open. Therefore, please return to the system status screen after system setting.
3-4. Menu Screen 3-4-2. Menu screen of the secondary station To call the menu screen of the secondary station, select menu item [R: CALL SECONDARY STATION] in the primary station menu and input the secondary station number. To set the secondary station function of the routing switcher used as the primary station, input “1” as the secondary station number. The screen will return to the menu screen of the primary station when [Ctrl] _ [D] is pressed.
3-4. Menu Screen 3 DVS-RS1616/TC3232/A3232, BVS-V3232/A3232 SONY ROUTING SYSTEM SETUP MENU DVS-RS1616 V3.01 STATION NUMBER 7 MODIFICATION COMMAND A: SET UNIT LOCATION K: DEFAULT TABLE G: UPDATE BACKUP CONTROLLER MAINTENANCE COMMAND Y: DISPLAY TABLE Z: SELECT CONNECTION Ctrl-D:RETURN Menu Screen of the Secondary Station (Ex. DVS-RS1616) n DVS-TC3232/A3232 and BVS-V3232/A3232 does not have menu item [Z]. 4 HDS-V3232 SONY ROUTING SYSTEM SETUP MENU HDS-V3232 V1.
3-4. Menu Screen (2) Remote control unit 1 BKS-R3202 SONY ROUTING SYSTEM SETUP MENU BKS-R3202 V3.10 STATION NUMBER 16 MODEFICATION COMMAND H: SET PHANTOM TABLE N: SET PANEL TABLE O: SET AVAILABLE DESTINATION L: COPY TABLE DATA S: DISPLAY DESCRIPTION NAME Ctrl-D:RETURN Menu Screen of the Remote Control Unit (Ex. BKS-R3202) 2 BKS-R3204/R3205/R3206 SONY ROUTING SYSTEM SETUP MENU BKS-R3206 V3.
3-4. Menu Screen 3 BKS-R1607, BKS-R1608, BKS-R3209, BKS-R3210 SONY ROUTING SYSTEM SETUP MENU Å BKS-R1607 V1.00 STATION NUMBER 3 MODIFICATION COMMAND H: SET PHANTOM TABLE N: SET PANEL TABLE O: SET AVAILABLE SOURCE/DESTINATION R: SET ROUTE L: COPY TABLE DATA Z: SET PANEL STATUS S: DISPLAY DESCRIPTION NAME Ctrl-D:RETURN Menu Screen of the Remote Control Unit (Ex. BKS-R1607) n BKS-R1608/R3209 does not have the menu item [O].
3-4. Menu Screen 3-4-3. Menu screen of the primary station on monitor S-BUS To call the menu screen of the primary station on the monitor S-BUS, select menu item [R: CALL SECONDARY STATION] in the primary station menu on the standard S-BUS. (The switcher set as the primary station on the monitor S-BUS.) Next, select menu item [M: SET MONITOR FUNCTION].
3-4. Menu Screen (2) Remote control unit 1 BKS-R3202 MONITOR SYSTEM SETUP MENU BKS-R3202 V3.10 STATION NUMBER 14 MODIFICATION COMMAND S: DISPLAY DESCRIPTION NAME Ctrl-Z:RETURN Menu Screen of the Secondary Station on Monitor S-BUS (Ex. BKS-R3202) 2 BKS-R3204, BKS-R3205 MONITOR SYSTEM SETUP MENU BKS-R3204 V3.
3-5. Setting Screen 3-5. Setting Screen Set the items in the menu in the setting screen. To call the setting screen, select the menu item with the cursor key or input it using the alphabet key, and press [Enter]. (The same procedure for calling the setting screen is applied to both the primary station menu and secondary station menu.) The screen returns to the menu screen when [Ctrl] _ [E] is pressed at each menu item. Then if [Ctrl] _ [X] is pressed, the screen will return to the system status screen.
Section 4 Setup Procedure 4-1. Outline This setup procedure is written for the setup operator to understand the setup procedure, and more importantly, the philosophy behind the setup. Time spent now, before actually sitting down at the Setup Terminal will greatly enhance the flexibility of your router system (routing switcher system). If your system is only comprised of DVS-V**** routing switchers the setup approach is much simpler, and pretty strait forward.
4-2. Preliminary Information Before Installation 4-2. Preliminary Information Before Installation The control area of each switcher when used as the primary station is as follows.
4-3. Preparation Before Setup 4-3. Preparation Before Setup 1. Set a primary station DVS-V6464B or DVS-V3232B is recommended as the primary station. Set M/S switch on the CPU-149 board to “M” position*1. Station ID automatically will equal one. n Set only one primary station. If more than two are set as the primary, they will not work correctly. 2. Connect PC Connect a IBM compatible PC with MS-DOS Ver. 6.
4-4. Basic Setup Procedures 4-4. Basic Setup Procedures 1. Identify all in/out signals, and segregate them into 16 types of sources and destinations (1) Make IN/OUT list of each routing switcher Make input/output list of each routing switcher referring to installation, or wiring diagram or other documentation showing router interconnection. Figure 1 shows an example of a 3 router system. It is composed of an SDI, AES/EBU, and a Analog routing switcher.
4-4.
4-4. Basic Setup Procedures (2) Assign Name Types (Menu Item [B]) Now select, and enter your 16 source and destination name pre-fixes. Once again, up to 16 type names used for source/destination name are decided using 4 letters (except “;”). Set using the menu item [B : SET SOURCE/DESTINATION TYPE]. Example : CAM, VTR, CG, DVE, MON, PGM, BLK, DAT, STL, TONE, CD, ... If a consistent display format is desired, all name types should be the same length.
4-4. Basic Setup Procedures Figure 2 shows that no two levels need to occupy the same size space in the X, and Y directions. As our example in figure 1 demonstrates, level 1 could be 32 by 32 in 2 dimensional X, Y space, while levels 2, and 3 are only 16 by 16. Actually each level could occupy different size X, and Y space. Finally, it should be clear that Z “depth”, is three in our case since we have 3 levels. Levels Can occupy different size 2 dimensional space Level 1 Level 2 Z Y X Level 3 Fig.
4-4. Basic Setup Procedures Going back to the VTR 1 example, each of the 3 routing switcher outputs (SDI, AES/EBU, and analog audio) could be assigned to a different level, under the VTR001 label. Whenever destination VTR001 was selected all 3 crosspoints in the 3 different routing switchers would switch together. This approach is often the simpler approach to implement, and understand, but it can limit future flexibility in operation, as we will see.
4-4. Basic Setup Procedures With this approach, you need the control terminal connected to the primary routing switcher, or a control panel that allows access to individual “levels”, like the BKS-R1607, BKS-R1608, BKS-R3209 or BKSR3210 to control only one level of VTR001 routing. Figure 4 shows this approach.
4-4.
4-4. Basic Setup Procedures Example : Destinations . Satellite 1 connected to SDI routing switcher OUT 9 (SDI routing switcher given label destinations 001-032) . DAT 1 connected to AES/EBU routing switcher OUT 9 (AES/EBU routing switcher given label destinations 033-048) .
4-4. Basic Setup Procedures With this approach sources, and destinations like the VTR’s would be level mapped together so that all 3 routing switchers switch at the same time under the VTR001, VTR002, etc. label.
4-4.
4-4. Basic Setup Procedures Now select suitable names for sources/destinations using Type name, and number and enter them in the IN/OUT list of each routing switcher (menu item [C]). Remember that you have to attention to the ins, and outs of routing switchers on all levels when you build this list.
4-4. Basic Setup Procedures 3. Set Level Table (Menu Item [E]) This is the step where you assign what levels you want each name or label to be assigned to. You also assign the names of the various levels (here SDI, AES, and AUD are used). The information entered here was derived from figure 7.
4-4. Basic Setup Procedures 4. Physical Assignment (Menu Item [L]) Now we actually associate the labels or names to a physical routing switcher input or output. Assign the physical source/destination number and the physical level to the virtual source/destination name and the virtual levels using the menu item [L : SET PHYSICAL ASSIGNMENT]. Again refer to figure 7. PHYSICAL NUMBER ASSIGNMENT SOURCE LEVEL No.
4-4. Basic Setup Procedures Additionally, an individual routing switcher can be divided in 2, or more virtual routing switchers. This means that one level can be made to look like 2, or more levels. In our example our 3 level routing switcher could have the AES/EBU routing switcher split into 2 virtual levels. Our 3 routing switcher system would now have 4 levels.
4-4. Basic Setup Procedures 5. Phantoms (Menu Item [H]) Now we will create any necessary phantoms. First we must define the phantom globally, and then allow it’s usage by individual control panels. A phantom allows you to have a number of outputs select new inputs all at once. An instance of a global in our example would be the selection of input SAT001 (SDI level and the Analog audio level) to output VTR001, and DIG201 (AES level) to output VTR001. We could call this phantom SAT999.
4-4. Basic Setup Procedures 6. Decide Remote Control Units Can Be Active on the S-BUS (1) Available Stations (Menu Item [F]) Make secondary stations available by setting “E” on the menu item [F : SET ACTIVE UNIT NUMBER. The stations that are enabled will be polled by the primary, for panel activity, and status updates. ENABLE ACTIVE UNIT FOR STATION NUMBER 001-020 021-040 1 2 3 4 5 M E E E E 6 7 8 9 10 E E E DVS-V3232B V2.
4-4. Basic Setup Procedures 7. Inhibit Crosspoint Table (Menu Item [M]) Set invalid crosspoint table for the specified crosspoints that will not be allowed to be selected by various outputs INHIBIT TABLE on the primary station. On the table “X” means valid crosspoint, and “_” means invalid crosspoint. SET INHIBIT TABLE DEST. SOURCE 001 01--08 09--16 VTR001 -X-XXXXX XXXXXXXX VTR002 XXX-XXXX XXXXXXXX VTR003 XXXX-XXX XXXXXXXX VTR004 XXXXX-XX XXXXXXXX DVS-V3232B V2.
4-4. Basic Setup Procedures Instead of one large routing switcher, there are often 2 separate routing switchers. One handling 4:2:2, and the other 4fsc. The output of the 4:2:2 would cascade through the 4:2:2 to 4fsc converters, and on to the inputs of the 4fsc routing switcher. The opposite configuration would be set up for going from 4fsc to 4:2:2. What is done here is that groups of inputs are combined in a Source Name group, along with groups of outputs known as Destination Name groups.
4-4. Basic Setup Procedures 9. Description Name (Menu Item [J]) In addition to Type + Number names, letter names (16 letters can be displayed on the BKS-R3281, most through only display 7) can be used. This is called a “Description name”. To set to Description names mode, select DESCRIP.NAME using the menu item [J : NAME STYLE]. Everytime [J] is selected in the System Setup Menu the name mode toggles between Type + Number, and Description name modes.
4-4. Basic Setup Procedures 10. Control Panel Setup (Menu Item [R]) Each individual control panel is contacted, and programmed by selecting [R] in the setup menu, and then by entering the S-BUS address of the desired panel. If the control panels are enabled in the menu item [Z : SET UNIT DETECTABLE], this might help you identify the panels address in question.
4-5. Flowchart of Setup 4-5. Flowchart of Setup Modification Initial Setting Primary Station Setting DVS-V3232/FV6464B : Set S3 to "D" (Default) position on the CPU-149 board, then return S3 to "0" position. HDS-V3232 : Set S2 to "D" (Default) position on the CPU-251 board, then return S2 to "0" position.
4-6. Setting Up BKPF-300/301/350/351 4-6. Setting Up BKPF-300/301/350/351 1. Set the switch S1-3 on BKPF-300/301/350/351 to “OFF (TERMINAL)” position. 2. Select the menu item [R: CALL SECONDARY STATION] from the menu screen of primary station, and call BKPF-300/301/350/351. The following screen appears. SONY ROUTING SYSTEM SETUP MENU SOURCE No: 0001 - 0008 Model name Software version indication BKPF-300 VX.
Section 5 System Settings 5-1. Setting Items of the Primary Station A : DISPLAY CONTROL AREA A : DISPLAY UNIT LOCATION Purpose The menu items [A : DISPLAY CONTROL AREA] and [A : DISPLAY UNIT LOCATION] are used to check the source and destination area of the whole routing system to be controlled by the primary station. Checking Procedure 1. Select menu item [A]. 2. Control area is displayed as shown below. Press [Ctrl] _ [E] to return to the menu screen. DISPLAY CONTROL AREA DVS-V6464B V2.
5-1. Setting Items of the Primary Station B : SET SOURCE/DEST TYPE C : SET DESTINATION NAME Purpose This menu is used to set the type name of the source destination and global phantom table. The menu makes the management of source/destination easier. Purpose This menu is used to set the destination name and protect function of each output. A number between 001 to 999 and a type name set at the menu item [B : SET SOURCE/DEST TYPE] can be set to each destination.
5-1. Setting Items of the Primary Station n 1. The same destination name cannot be registered at more than two destinations. If this is done, an error message will be displayed at the bottom of the screen. Example: “VTR001 is used already; Ignored” destination name 2. When the Description name mode is selected at menu item [J], both Description name and “Type + number” name will be displayed. In this menu, Description name is used for setting. Setting Procedure (Protect Function) 1.
5-1. Setting Items of the Primary Station D : SET SOURCE NAME Purpose This menu is used to set the source name and secret function (inhibition of source selection with a remote control unit). A number between 001 to 999 and a type name set at the menu item [B : SET SOURCE/DEST TYPE] can be set to each source name. Description name can be set by changing the name mode at menu item [J : NAME STYLE] in the menu. For details of setting the name, refer to [J] in the menu.
5-1. Setting Items of the Primary Station Operating Function Keys [F1] : SEARCH (To move the cursor to the desired source name) 1. When [F1] is pressed, “Please Input SOURCE NAME =” will be displayed. 2. Input the source name to be retrieved. 3. When [Enter] is pressed, the cursor will move to the desired source name. n When menu item [J] is set to the Description name mode, [F1] (SEARCH) will have the following functions. 1. When [F1] is pressed, “Please Input * * * * NAME =” will be displayed. 2.
5-1. Setting Items of the Primary Station E : SET LEVEL TABLE Purpose This menu is used to assign the level name and the level to each destination name. Up to eight levels can be set. In this menu, set only the necessary levels. If levels which have not actually been used are set, the response of the routing switcher system will become slower. Delete all levels not needed. After setting this menu item, the selected levels can be checked by remote control unit. Setting Procedure (Setting of Level Names) 1.
5-1. Setting Items of the Primary Station F : SET ACTIVE UNIT NUMBER G: UPDATE BACKUP CONTROLLER Purpose This menu is used to enable the units connected to the SBUS data link to communicate. Purpose This menu is used to copy the table data stored in the main CPU board of the primary station to the backup CPU board. This setting is valid only when the backup CPU board is installed in the primary station. Setting Procedure 1. Select menu item [F]. 2.
5-1. Setting Items of the Primary Station H : SET GLOBAL PHANTOM The phantom function switches several crosspoints together with one button pushing of a remote control unit. The crosspoints of different levels can be also switched with this function. There are two kinds of phantoms such as local phantom and global phantom (refer to the menu item [H : SET PHANTOM TABLE] of secondary stations for local phantom).
5-1. Setting Items of the Primary Station 3. As the cursor is placed where the name is typed, press [Enter]. The input mode will be set. 4. Select the codes assigned to each type name and enter any number using the cursor. Press [Enter] key to set it. Press [Ctrl] _ [P] to delete the phantom name. 5. Move the cursor to the place to input the destination and press [Enter]. The input mode will be set. 6. Input the destination name with the alphabet or numerical keys and press [Enter] to set it. 7.
5-1. Setting Items of the Primary Station J : NAME STYLE Purpose This menu is used to switch the name styles of the destination and source. The “Type + Number” name (Type + Num) or “Description” name (DESCRIP. NAME) can be set. Names on the setting screen of menu items [C], [D], [E], [H], [L], [M], [N], [O], and [Q] are switched according to this menu. Operating Function Keys [F1] : SEARCH (To move the cursor to the desired destination name) 1.
5-1. Setting Items of the Primary Station K : RESET TO DEFAULT TABLE K : DEFAULT TABLE Purpose This menu is used to initialize the table data. Do not perform this menu when modifying the table data. Setting Procedure 1. Select menu item [K]. The message “RESET TO DEFAULT TABLE? (y/n)” will be displayed at the bottom of the screen. 2. Initialization is performed when [Y] is pressed. To cancel initializing, press [N]. n The table data will be lost when performing the menu item [K].
5-1. Setting Items of the Primary Station . Destination Number Setting Procedure Press [F5] to set the destination number setting screen. Then, perform the same procedure as for source. PHYSICAL NUMBER ASSIGNMENT DESTINATION No. NAME 001 OUT001 002 OUT002 003 OUT003 004 OUT004 005 OUT005 006 OUT006 007 OUT007 008 OUT008 009 OUT009 010 OUT010 011 OUT011 012 OUT012 013 OUT013 014 OUT014 015 OUT015 016 OUT016 017 OUT017 018 OUT018 LEVEL VID A1 001-1 001-2 002-1 ...-.
5-1. Setting Items of the Primary Station M: SET INHIBIT TABLE Purpose This menu is used to protect source numbers not to be selected for each destination. When the secret function is set to a source name, the selected source cannot be output to all destinations. By using this menu, source numbers to be inhibited can be assigned for each destination. Setting Procedure 1. Select menu item [M]. 2. Select the source number for each destination name using the cursor.
5-1. Setting Items of the Primary Station N : SET DESCRIPTION NAME GROUP Purpose To register the Description names required for each remote control unit, set the group of Description names. Up to eight such source and destination groups can be set. (Up to 160 names can be registered for one group.) The top half of the screen is for setting the group and the bottom half displays the list of Description names. Setting Procedure 1. Select menu item [N]. 2. Move the cursor to the group number by pressing [B].
5-1. Setting Items of the Primary Station . Transferring Data to the Secondary Station on the Monitor S-BUS To transfer the data on the group setting screen currently displayed to a secondary station on the monitor S-BUS, the number of the primary station on the monitor S-BUS must be specified, in addition to the secondary station number. Specify in the following way.
5-1. Setting Items of the Primary Station O: SET TIE LINES Purpose This menu is used to store the connection information of the matrix in the primary station and to set the tie line for switching several crosspoints using the remote control unit button. Using this method, peripheral units such as the signal converters can be used more efficiently. The tie line consists of four input/output connectors as one group and paths connected between sources and destinations.
5-1. Setting Items of the Primary Station 8. Select the number of net group with cursor keys and press [Enter] to set the input mode. Set the signal path between two routing switchers, using the combination of the “OUT of the front stage” > “IN of the latter stage”. 9. Input the source number and the destination number with the numerical keys and press [Enter] to set it. When change the level, move the cursor to the level and press [Enter]. 10.
5-1. Setting Items of the Primary Station P : CHANGE PASSWORD Q: CHANGE CROSSPOINT Purpose This menu is used to change the password. Purpose This menu is used to display the crosspoints and change them. Setting Procedure 1. Select menu item [P]. 2. Input the password currently set, and press [Enter]. In the default status, password is not set in DVSV3232B/V6464B. Once the password is set, the menu items can not be set or changed unless the password is entered.
5-1. Setting Items of the Primary Station Operating Function Keys [F1] : SEARCH (To select a destination name) 1. When [F1] is pressed, “Please Input DEST NAME =” will be displayed. 2. Input the destination name to be retrieved. In the Description name mode, input the Description name (within seven characters) from the head. 3. When [Enter] is pressed, the destination name entered will be searched. 4. If the desired name does not exist in the screen, press [F1] again.
5-1. Setting Items of the Primary Station R : CALL SECONDARY STATION Purpose This menu is used to call the menu of the secondary station connected to the S-BUS of the primary station. Operating Procedure 1. Select the menu item [R] at the menu screen. A message will be displayed on the screen. 2. Enter the station number of the secondary station, and press [Enter]. The display will be changed to the menu screen of the secondary station. 3.
5-1. Setting Items of the Primary Station U : SELECT REMOTE Purpose This menu is used to control the routing switcher using the 9-pin remote (REMOTE 2), and to set the control mode to the DIRECT mode or the S-BUS conversion mode. Setting Procedure 1. Select menu item [U]. 2. Select channel using the cursor keys. 3. Press [Enter], and the setting condition displayed will be changed.
5-1. Setting Items of the Primary Station V : SELECT WARNING DISPLAY Purpose This menu is used to set the warning message displayed on the system status screen. n Some messages will not be displayed, depending on the models. Setting Procedure 1. Select menu item [V]. 2. Press [V], [Enter], and the setting conditions displayed will be switched.(“ON” → “OFF”).
5-1. Setting Items of the Primary Station W:SYSTEM STATUS LOG X : DISPLAY S-BUS COMMUNICATION Purpose This menu is used to check the error during self-diagnosis of each station, the status of the S-BUS circuit, and the time of events. Purpose This menu is used to display the S-BUS data received at the primary station. SYSTEM STATUS LOG 1990.10.12-15:42 1990.10.27-09:28 1990.11.03-05:31 1991.01.14-13:51 1991.02.01-11:15 1991.02.04-06:11 -- end -- DVS-V6464B V2.
5-1. Setting Items of the Primary Station Y : DISPLAY TABLE (Except for HDS-V3232) Z : SET UNIT DETECTABLE Purpose This menu is used to display the table data set with the control terminal. Purpose This menu is used to check the possibility of communication of secondary stations connected to the S-BUS data link periodically. During checking, “?” appears. After the completion of checking, the code number indicating the type of each device appears.
5-2. Setting Items of the Secondary Station 5-2. Setting Items of the Secondary Station A:SET UNIT LOCATION Purpose This menu is used to set the input/output location of the routing switcher. Setting Procedure 1. Select menu item [A]. 2. Use the cursor keys ([&], [*] to select the setting item. 3. When [Enter] is pressed, the offset value of the input number and the output number can be typed. 4. Enter the offset value using the numerical keys. 5. Press [Enter] to set the offset value.
5-2. Setting Items of the Secondary Station G:UPDATE BACKUP CONTROLLER Purpose This menu is used to copy the table data stored in the main CPU board of the secondary station to the backup CPU board. This setting is valid only when the optional CPU board is installed to the secondary station. Setting Procedure 1. Select menu item [G]. The message “This process requires about 1 minutes. Execute? (y/n)” will be displayed at the bottom of the screen. 2. Table data copying is performed when [Y] is pressed.
5-2. Setting Items of the Secondary Station H : SET PHANTOM TABLE Purpose This menu is used to set PHANTOM which switchers several crosspoints, using the source selection button of the remote control unit. Setting Procedure 1. Call the menu screen of the remote control unit to be set, using menu item [R], and then select menu item [H]. 2. Select a item using the cursor. 3. When [Enter] is pressed, the phantom table can be set. If [Enter] is pressed before setting, the registration will be deleted. 4.
5-2. Setting Items of the Secondary Station 5. When [Enter] is pressed, the phantom table will be set. 6. When [Ctrl] _ [E] is pressed, the menu screen of the secondary station will be displayed. When [Ctrl] _ [D] is pressed, the menu screen of the primary station will be displayed. . Execution of Phantom Function When the phantom function is performed by a remote control unit, its operation conforms to this phantom table.
5-2. Setting Items of the Secondary Station K : RESET TO DEFAULT TABLE K : DEFAULT TABLE Purpose This menu is used to initialize the table data. Do not perform this menu when modifying the table data. Setting Procedure 1. Select menu item [K]. The message “RESET TO DEFAULT TABLE ok ? (y/n)” will be displayed at the bottom of the screen. 2. Press [Y] to process the initialization. To cancel initializing, press [N]. n The table data will be lost note when performing the menu item [K].
5-2. Setting Items of the Secondary Station M: SET MONITOR FUNCTION (Except for HDS-V3232) N : SET PANEL TABLE (BKS-R1601/R3202/R3203) Purpose This menu is used to set the monitor S-BUS. As this monitor function is controlled by the local CPU, it has a monitor data link that is independent from the standard SBUS data link. Therefore, it is necessary to set the primary station and secondary stations for the monitor S-BUS. Purpose This menu is used to assign source name to each source selection button.
5-2. Setting Items of the Secondary Station N : SET PANEL TABLE (BKS-R1607/R1608/R3204/R3205/R3209/R3210/R1617/R1618/R3219/R3220/R1621) Purpose This menu is used to assign source/destination name to each source/destination button. Setting Procedure 1. Select menu item [N]. 2. Select a button number using the cursor. 3. When [Enter] is pressed, the panel table can be typed. To delete the registration, press [Enter] before inputting the name. 4.
5-2. Setting Items of the Secondary Station N : SET PANEL TABLE (BKS-R3206/R3216) 4. When “T : TAKE M : MONI” is displayed on the screen, it means that the button on the source side can be set as the TAKE button or MONI button. Before pressing [Enter], select a key from the source side. To set it as the TAKE button, press [T]; to set it as the MONITOR button, press [M]. 5. When “V : VTR” is displayed on the screen, it means that the VTR control function can be assigned to the buttons on the source side.
5-2. Setting Items of the Secondary Station O: SET AVAILABLE DESTINATION (BKS-R3202/R3206) O: SET AVAILABLE DESTINATION (BKS-R1607/R3210/R3216/R1617/R1618/R3219/ R3220/R1621) Purpose This menu is used to set the destination which can be selected by the remote control unit. Setting Procedure 1. Call the menu screen of the remote control unit to be set using menu item [R], and then select menu item [O]. 2. Select the destination using the cursor.
5-2. Setting Items of the Secondary Station . Procedure of setting SELECT SOURCE NAME (Input) 1024 101 164 1. Select an item to set using the cursor key. 2. Pressing [Enter] establishes the source name input mode. 3. Enter the “Type + No.” name or description name. 4. Press [Enter] to confirm the input contents.
5-2. Setting Items of the Secondary Station Example of setting : SRC TOP-SRC END=DST TOP-DST END indicates the applicable range of the offset-type phantom on the screen of example setting. When the range from IN001 to IN008, and the range from OUT001 to OUT004 are to be set as the applicable range, enter as follows. IN001-IN008=OUT001-OUT004 When you want execute the combinations of OUT001
5-2. Setting Items of the Secondary Station R : SET ROUTE (BKS-R1607/R1608/R3209/R3210/R3216/R1617/R1618/R3219/R3220/R1621) Purpose This is the function to display the source names that are expanded by combining the two switchers for the purpose of expanding numbers of input. When a route is set, the source that is connected to the route destination, is automatically chased out the and the name of the source is displayed.
5-2. Setting Items of the Secondary Station S : DISPLAY DESCRIPTION NAME Purpose This menu is used to check the group and names of the Description transferred from the primary station. Check Procedure 1. When [Enter] or [SPACE] is pressed, the screen will be changed to the next page. 2. When [BS] or [DEL] is pressed, the screen will be changed to the previous page. 3. Press [Ctrl] _ [E] to display the menu screen of the secondary station.
5-2. Setting Items of the Secondary Station U : SELECT REMOTE PROTOCOL Purpose This menu is used to set channels A and B of REMOTE 2 (D-sub 9-pin) to loop-through. When the REMOTE 2 control mode is set to DIRECT, this menu is used to set the protocol and the conversion table of the input/output numbers. There are three kinds of protocols. . PRODUCTION SWITCHER PROTOCOL . AUDIO MIXER PROTOCOL . CART PROTOCOL n AUDIO MIXER PROTOCOL was known as “SWITCHER PROTOCOL” before.
5-2. Setting Items of the Secondary Station V : DISPLAY UNIT STATUS (Except for HDS-V3232) Y : DISPLAY TABLE DATA (Except for HDS-V3232) Purpose This menu is used to display the status of the hardware such as boards, etc. n For the input/output boards and matrix boards of DVSV3232B, channel 1 to 32 will be displayed. And FAN 1 and 2 will be displayed for DVS-V3232B. Purpose This menu is used to display the table data set with the control terminal. Operating Procedure 1. Select menu item [V]. 2.
5-2. Setting Items of the Secondary Station Y : SET DISPLAY MODES (BKS-R3216/R1617/R1618/R3219/R3220/R1621) Purpose This menu is used to set the display mode. The setting contents are as follows. DISPLAY MODES (BKS-R3216/R3220): Selects the display type. (when J : NAME STYLE (DESCRIP.NAME) is selected in the primary station menu.) NORMAL = Normal display 2 + 2CHAR = Displays two letters before and after the name. 4CHAR = Displays four letters from the beginning of the name.
5-2. Setting Items of the Secondary Station Z : SELECT SDI FORMAT (Except for HDS-V3232) Purpose This menu is used to set the format of signals fed to the input/output board of DVS-V3232B and DVS-V6464B with the control terminal. This setting is available when the manual switch for the format on each input/output board is OFF. Setting Procedure 1. Select menu item [Z]. 2. Select a channel line using the cursor to be set. (The channels will be switched by eight channels.
5-2. Setting Items of the Secondary Station Z : SET PANEL STATUS (BKS-R3204/R3205/R3206) Purpose Besides the remote control unit can be used alone, several units can be used together as if it were one unit with expanded sources and destinations. When using several units together, one will serve as the mother and the rest will serve as the daughters. This menu is used to perform the settings necessary in such cases.
5-2. Setting Items of the Secondary Station SONY ROUTING SYSTEM SETUP MENU SET PANEL STATUS PANEL MODE = 1 1:STAND ALONE BKS-R3205 V3.10 STATION NUMBER 11 2:MOTHER SET SOURCE OR DESTINATION ASSIGNMENT KEY 1- 8 = S KEY 9-16 = S KEY 17-24 = S KEY 25-32 = S S:SOURCE D:DESTINATION SET BLOCK NUMBER=3 MOTHER STATION BLOCK LIST BLOCK 1 = STATION 11 | BLOCK 6 BLOCK 2 = STATION 5 | BLOCK 7 BLOCK 3 = STATION 2 | BLOCK 8 BLOCK 4 = STATION 3 | BLOCK 9 BLOCK 5 = ....... | BLOCK10 Ctrl-E:MENU = = = = = ....... ....
5-2. Setting Items of the Secondary Station LEVEL MODE*1 SINGLE = Single level selection MULTI = Multiple level selection DEST SELECTION*2 DISABLE = Change of destination from the panel is prohibited. ENABLE = Change of destination from the panel is allowed. ILLUMINATION LEVEL*3 Brightness of the button indicator : 1 (dark) to 8 (bright) MONITOR DESTINATION*3 Enter the name of the destination to be monitored (when the MONI button is selected).
5-2. Setting Items of the Secondary Station Mother panel : 1) Select “PANEL MODE = 2” (mother machine). 2) Press [Enter]. The following contents are displayed on the setting screen. SET BLOCK NUMBER = * MOTHER STATION BLOCK LIST BLOCK 1 = ....... | BLOCK 6 BLOCK 2 = ....... | BLOCK 7 BLOCK 3 = ....... | BLOCK 8 BLOCK 4 = ....... | BLOCK 9 BLOCK 5 = ....... | BLOCK10 = = = = = ....... ....... ....... ....... ....... 3) Input the unused BLOCK number of the BLOCK & MOTHER STATION LIST into the “*” column.
5-2. Setting Items of the Secondary Station Z : SELECT CONNECTION (DVS-RS1616 only) Z : SWITCHING FIELD (HDS-V3232 only) Purpose As for DVS-RS1616, this menu is used to set, “M” (controlling side) or “S” (controlled side) for each 9-pin connector from 1 to 32. If a controller is connected to a 9-pin connector, set to (S). If a controlled device is connected to a 9-pin connector, set to (M). When setting to (S), termination is automatically made.
5-3. Setting Items of the Primary Station on Monitor S-BUS (BKDS-V3292B only) 5-3. Setting Items of the Primary Station on Monitor S-BUS (BKDS-V3292B only) Used for setting the units on the monitor S-BUS. SET MONITOR FUNCTION DVS-V6464B Monitor Bus I/F V2.10 MODIFICATION COMMAND F: SET SCTIVE UNIT NUMBER M: SELECT MONITOR FUNCTION (COMBINED) R: CALL SECONDARY STATION Ctrl-E:RETURN TO MENU Menu Screen of the Primary Station on Monitor S-BUS Setting Procedure of Monitor Function 1.
5-3. Setting Items of the Primary Station on Monitor S-BUS (BKDS-V3292B only) M: SELECT MONITOR FUNCTION R : CALL SECONDARY STATION Purpose This menu is for setting the connection to use the input monitor and output monitor in series or independently. To monitor the input and output monitor lines using separate monitors, set the SEPARATED mode. To monitor them together on one monitor, set the COMBINED mode. Purpose This menu is used to call the secondary station on the monitor S-BUS.
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) 5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) L : COPY TABLE DATA Purpose This menu is used to copy the setting contents of the remote control unit. This is applied to BKS-R3204 and BKS-R3205. M: SET AVAILABLE MONITOR LINE (DVS-V3232B/V6464B + BKDS-R3292B) SET MONITOR FUNCTION DVS-V6464B Monitor Bus I/F V2.
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) N : SET PANEL TABLE (BKS-R1607/R1608/R3204/R3205/R3209/R3210) Purpose This menu is used to assign source/destination name to each source/destination selection button. In the monitor mode, the button color of the remote control unit will be green for both source and destination. Setting Procedure 1. Select menu item [N]. 2. Select a button number using the cursor. 3. When [Enter] is pressed, the name can be typed.
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) S : DISPLAY DESCRIPTION NAME n In BKS-R1607 of version V1.10 and higher, any desired button among the sixteen buttons can be set as a TAKE button. When this setting is performed, the name selected by the SELECTOR knob on the front panel can be taken by pressing the TAKE button. (Maximum inputs 512 x outputs 512) The actual setting procedure is as follows.
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) n In BKS-R1607/R1608/R3209/R3210 of version V1.10 and higher, the 160 description names that are transferred from the primary station can be registered in the range of inputs 512 x outputs 512 in the order of terminal number regardless of the block number. When you want to use more than 160 of the description names, transmit the names from the primary station after dividing the description names into several blocks.
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) Setting Procedure 1. Select menu item [Z]. 2. The cursor appears at “DISPLAY MODE=1.” Move the cursor to the desired mode. (Use the keys [(], [)].) Press [Enter] to enter the input mode. 3. Input the number to be selected using the numerical keys. Press [Enter] to set the input number. The cursor moves to the setting item. When you want to modify the default value, press [Enter] without inputting any number.
5-5. Backup of Setting Data 5-6. When Data is Lost 5-5. Backup of Setting Data The data set using the control terminal will be stored in the RAM on the CPU board. It is however recommended that the setting data be backed up just in case the data is damaged or lost. Data can be backed up easily by using the Sony routing switcher system control software BZR-1000 (run with a IBM PC/AT or compatible machine) or BZR-10. 5-6.
5-7. Initialization of Table Data 5-7. Initialization of Table Data There are five ways of initializing the table data. Note that the way to be used depends on which item is initialized. 5-7-1. Initializing Procedure and Corresponding Items DVS-V3232B/V6464B : Initializing Procedure Corresponding Menu Items 1 1. Set the test switch (S3) on the CPU-149 board to “D”. 2. Press the reset switch (S5). All items of the primary and secondary stations. 2 1.
5-7. Initialization of Table Data HDS-V3232 : Initializing Procedure Corresponding Menu Items 1 1. Set the test switch (S2) on the CPU-251 board to “D”. 2. Press the reset switch (S8). All items of the primary and secondary stations. 2 1. Set the test switch (S2) on the CPU-251 board to “C”. 2. Press the reset switch (S8). [W : SYSTEM STATUS LOG] 3 Select the menu item [K : RESET TO DEFAULT TABLE] of the primary station and press [Y].
5-8. Signal Switching Timing 5-8. Signal Switching Timing For DVS-V3232B/V6464B and HDS-V3232, a SWITCHING FIELD which switch signals from the control terminal can be set. The SWITCHING FIELD are set using menu item “Z” of the secondary station and any SWITCHING FIELD mode (ODD, EVEN, FIELD, ASYNC) can be selected. The signal switching timing depends on whether it is controlled by RS-422A or the S-BUS. The following shows the timing charts of RS-422A and S-BUS for each SWITCHING FIELD mode. .
Section 6 Confirmation of function 6-1. Outline After the hardware and software have been set up, it is necessary to check if the system is working properly before starting the operation. Each routing switcher is equipped with the self-diagnosis function to check the system connection and status of each unit. As soon as the power of the unit is supplied or the system is reset, this function begins operations which check internal conditions and connections automatically.
6-2. Function Check Format 6-2. Function Check Format The contents of each function and the structure of the error displays are as follows. LED Display for Internal Information Test Mode Function LED displays the presence/absence of the signals and setting of the switches independently, irrespective of the selfdiagnosis and test mode. Test mode is effective for finding the causes of the error and the faulty sections which have been detected by the self-diagnosis function.
6-3. How the Self-Diagnosis Items are Related 6-3. How the Self-Diagnosis Items are Related Status Indicator *1 Control Terminal Display Lit in Green: Operating Normally Blinking in Green: Faulty sync signal detection Blinking in Red: Faulty crosspoint hardware Increase in the switcher's internal temperature/Fan has stopped Error No.
6-4. Diagnosis Items for Each Model 6-4. Diagnosis Items for Each Model Self-diagnosis Items Error Display Model *1 Status Indicator Status display *1 Error No.
6-5. Function Check Process 6-5. Function Check Process After installing the hardware and software of the routing switcher system, check its functions and those of each device according to the following procedures. The process of the function check consists of three steps. The checks in step 2 and onward will be performed only when errors have been detected in step 1. If not, the checking process ends there.
6-6. Function Check with Control Terminal 6-6. Function Check with Control Terminal There are two types of display modes for operation check from control terminal, which can be selected depending upon the purpose. The first type of display mode is provided by the system status display and the other is provided by the “W” menu on the menu display. The system status display shows result of self diagnostics that is performed automatically by the primary station when the main power of the system is turned on.
6-6. Function Check with Control Terminal 6-6-2. System status screen during the system operation When a message is output to the S-BUS data link, the system status screen will display this message with the date and time of occurrence. When an error occurs during the operation of the system, the error message will be displayed. 1990.10.12-15:42 1990.10.27-09:28 1990.11.03-05:31 1991.01.14-13:51 1991.02.01-11:15 1991.02.04-06:11 S-BUS LINK DISCONNECTED STARTED BY BKS-R1601 Ver3.
6-6. Function Check with Control Terminal 6-6-4. Contents and countermeasures of the error messages The control terminal will display eleven types of error messages according to the error content. However, depending on the model, some are not used because of no detection, or some part of the message may differ. For details of the messages and their countermeasures, refer to operation manuals provided with each model. Standard error messages and their countermeasures are as follows.
6-6. Function Check with Control Terminal DIFFERENT CHECK SUM= ???? IN STATION * * * Check sun value Content : This message is displayed when an error has been detected as the result of ROM checksum and RAM writing tests performed after resetting the unit. Countermeasure : Replace the corresponding ROM. n This error message will be displayed even after the ROM has been replaced. This is normal.
6-6. Function Check with Control Terminal STATION * * * FAILURE(DISCONNECTED OR POWER DOWN) Content : This message is displayed when communication with the station set at the menu item [F] is stopped. Countermeasure : Check the status indicator of station * * *, and perform the adjustment corresponding to the symptom. VALID INPUT OR OUTPUT BOARD IN STATION * * * Content : This message is displayed when the input/output board has been inserted to station * * *.
Section 7 Change Information on DVS-128/HDS-X3000 Series and DVS-V3232M/V6464M 7-1. Outline (DVS-128/HDS-X3000 Series) The S-BUS protocol is extended of its virtual matrix size from 512 to 1024. At the same time the following functions are changed. . . . . . . Number of SOURCE/DEST TYPEs is extended from 16 to 32. Selection of either 1024 x 1024 x 8 level or 1024 x 512 x 16 level is added. Number of the GLOBAL PHANTOM is reduced from 4093 to 2800. The multi source assignment function is added.
7-2. Changed Menu (Primary Station Setting Items) 7-2. Changed Menu (Primary Station Setting Items) n The menu screen shown below is based on the DVS-128. Initial screen (DVS-128/HDS-X3000 Series) When the [Ctrl] _ [X] key is pressed after the main power is turned on, the following display appears. SONY ROUTING SYSTEM SETUP MENU DVS-128 V1.
7-2. Changed Menu (Primary Station Setting Items) A : DISPLAY CONTROL AREA (DVS-128/HDS-X3000 Series) B : SET SOURCE/DEST TYPE (DVS-128/HDS-X3000 Series) Purpose This menu displays the control size as the primary station. Purpose This menu is used to set the type name of the source destination and global phantom table. The menu makes the management of source/destination easier. The alphanumeric characters of 4 characters or less can be used.
7-2. Changed Menu (Primary Station Setting Items) E : SET LEVEL TABLE (DVS-128/HDS-X3000 Series) O : SET TIE LINES (DVS-128/HDS-X3000 Series) Purpose The level name can be set, and the valid level for each output terminal can be set. Number of levels of either 8 or 16 can also be selected. LEVEL TABLE No.
7-2. Changed Menu (Primary Station Setting Items) (Example) An example in which the three matrices of 10 x 10 are used and are connected by the Tie-Line, is shown. A signal of IN 1-10 and IN 13-20 can be selected from OUT 21-30 in this example. SET TIE LINES DVS-128 V1.00 STATION NUMBER 1 --PATHS 1-----------------------------------------------------------------SOURCE: SOURCE No. DESTINETION No. ROUTE: SOURCE No. DESTINETION No. L1 0001 - 0010 0009 - 0010 L2 0011 - 0012 0017 - 0018 DESTINATION:SOURCE No.
7-2. Changed Menu (Primary Station Setting Items) 7-3. Changed Menu (Secondary Station Setting Items) S : SET SOURCE ASSIGNMENT (DVS-128/HDS-X3000 Series) 7-3. Changed Menu (Secondary Station Setting Items) Purpose Change/addition/deletion of the MULTIPLE SOURCE name are performed here. When the signal name that has been set as level 1 from the remote control, is supposed to be named as TAKE, the signals whose source numbers are set here, can be selected in the level 2 and later.
7-3. Changed Menu (Secondary Station Setting Items) V : DISPLAY UNIT STATUS (DVS-128) Operating Function Keys [F1] : TABLE (Mode which assigns source and destination to the buttons) This setting is valid for local input/output physical terminals of the HDS-X3400. The SOURCE and DESTINATION of other unit cannot be set from this button. [F2] : LED (Mode which adjusts brightness of the button.) 1. Press [F2]. The cursor moves to [LED BRIGHTNESS LEVEL (1-8)] on the screen. 2.
7-3. Changed Menu (Secondary Station Setting Items) V : DISPLAY UNIT STATUS (HDS-X3000 Series) Purpose Purpose is to display the internal status of the equipment. There are no setting on this screen. Press [Ctrl] _ [E] to return to the menu screen of the secondary station. DISPLAY UNIT STATUS HDS-X3400 V1.00 STATION NUMBER 1 DISPLAY UNIT STATUS HDS-X3700 V1.00 INPUT 01-16 MAIN REVŁ HD SDI 1.0 CN 01-16 HD SDI REVŁ 1.0 P.
7-3. Changed Menu (Secondary Station Setting Items) Z : SET SDI FORMAT (HDS-X3000 Series) FANA, FANB : ROT/STOP Displays whether the fan on the matrix board is rotating or not. FANn : ROT/STOP Displays whether the fan of the main unit (except the power supply unit) is rotating or not. FRONT PANEL : BKS-R3400/INVALID Displays whether the option switch is attached to the front of the HDS-X3400 or not.
7-3. Changed Menu (Secondary Station Setting Items) SELECT SDI FORMAT HDS-X3600 V1.
7-3. Changed Menu (Secondary Station Setting Items) Z : SELECT SDI FORMAT (DVS-V3232M/DVS-V6464M) Purpose This menu is used to set the format of signals fed to the input/output board of DVS-V3232M and DVS-V6464M with the control terminal. This setting is available when the REM/LOC switch for the format on each input/output board is OFF. Setting Procedure 1. Select menu item “Z”. 2. Select a channel line using the cursor to be set. (The channels will be switched by eight channels.
7-3. Changed Menu (Secondary Station Setting Items) “AUTO” stands for “AUTO LOCK” mode in which the input signal format (143/177/270/360/540 Mbps) is automatically identified and the equipment runs on an appropriate signal format. The signal format setting can be changed by pressing either [Enter] or [F].
7-3.
Appendix Functions and Menu Items Function Purpose Menu item Station type Standard setting Initializing table data K : RESET TO DEFAULT TABLE Primary station Set/change password P : CHANGE PASSWORD Set time clock T : SET CLOCK Select warning display ON/OFF V : SELECT WARNING DISPLAY Set type name B : SET SOURCE/DEST TYPE Select input/output name style J : NAME STYLE Set destination name C : SET DESTINATION NAME Set source name D : SET SOURCE NAME Set description name group N : SET DES
Function Purpose Menu item Station type Monitor function Call secondary station R : CALL SECONDARY STATION Primary station Call primary station on monitor S-BUS M : SET MONITOR FUNCTION Secondary station Set active unit number F : SET ACTIVE UNIT NUMBER Monitor S-BUS Select monitor mode M : SELECT MONITOR FUNCTION primary station Call secondary station on monitor S-BUS R : CALL SECONDARY STATION Set available monitor unit Others A-2 M : SET AVAILABLE MONITOR LINE Monitor S-BUS Set panel
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation. Le matériel contenu dans ce manuel consiste en informations qui sont la propriété de Sony Corporation.
BVS-A3232 (SY) BVS-V3232 (SY) DVS-128 (SY) DVS-A3232 (EK) DVS-RS1616 (SY) DVS-TC3232 (SY) DVS-V1616 (SY) DVS-V3232B (SY) DVS-V3232M (SY) DVS-V6464B (SY) DVS-V6464M (SY) HDS-X3400 (SY) HDS-X3600 (SY) HDS-X3700 (SY) HDS-V3232 (JN) E 3-194-351-06 Sony Corporation Communication System Solutions Network Company Printed in Japan 2000.