DME PROCESSOR PACK MVE-9000-C MULTI FORMAT DME PROCESSOR MVE-9000 HK-PSU04 MKE-9020M MKE-9021M MKE-9040M INSTALLATION MANUAL 1st Edition
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. ! WARNUNG Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt. Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden.
For MVE-9000 Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit. 2. Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack, please confirm that the outlet is provided with a suitable protective earth connection. 3.
Table of Contents Manual Structure Purpose of this manual .............................................................................................. 2 Related manuals ......................................................................................................... 2 Contents ..................................................................................................................... 2 Trademark ..............................................................................................
Manual Structure Purpose of this manual This manual is the installation manual of DME Processor Pack MVE-9000-C and their optional boards and units. This manual is intended for use by trained system and service engineers, and describes the information on installing the MVE-9000-C system. Related manuals The following manuals are prepared for MVE-9000-C and their optional boards and units. . Operation Manual (Supplied with MVE-9000-C) This manual describes the application and operation of MVE-9000-C system.
Section 1 Installation 1-1. Operating Environment 1-2. Power Supply Operating guaranteed temperature : +5 dC to +40 dC Performance guaranteed temperature : +10 dC to +35 dC Operating humidity : 10 % to 90 % (relative humidity) Storage temperature : _20 dC to +60 dC Mass (when all options are installed) : Approx. 27 kg 1-2-1. Power Specifications Prohibited locations for installation . Areas where the unit will be exposed do direct sunlight or any other strong lights. . Dusty areas .
1-2-2. Recommended Power Cord This unit does not come with a power cord. To get a power cord, please contact your local Sony Sales Office/Service Center. w . Use the approved Power Cord (3-core mains lead)/ Appliance Connector/Plug with earthing-contacts that conforms to the safety regulations of each country if applicable. . Use the Power Cord (3-core mains lead)/Appliance Connector/Plug conforming to the proper ratings (Voltage, Ampere).
161 101.6 176(4U) 482 465 440 37.2 35 7 520 1-3. Installation Space (External dimensions) 17.5 375 144.5 61 115.5 380 115.
1-4. Installing the Options The MVE-9000-C is shipped from the factory with the necessary option (refer to the following table) already installed in the MVE-9000, in accordance with the specified system configuration. MVE-9000-C options Model name Installation procedure 1. Turn off the main power of the MVE-9000 and disconnect the AC power cord from the wall outlet. 2. Loosen the four screws (with drop-safe) and remove the front panel in the direction of the arrow.
4. While the eject levers are kept open as shown in the illustration, insert the plug-in board into the board guide rails. 5. While closing the eject levers in the direction of arrow 1, push in the plug-in board. 1 Eject lever Eject levers Name of option MKE-9040M Name of board DVP-24A board Slot on the front side *1 1 Eject lever 6. Attach the plug-in board loose-proof assembly and the front panel by reversing the installation steps 2, 3.
1-4-2. Installing the Connector Board The board slot Name of option Name of board Slot on the rear side MKE-9020M CN-2357A board 3 CN-2357B board 5 CN-2355A board 3 CN-2355B board 5 MKE-9021M Installation procedure 1. Remove the two screws and remove the blank panel. n Store the removed blank panel in a safe location. In the case of MKE-9020M Parts required (Supplied accessory of MKE-9020M) . Connecting cable . Harness support . Cover panel .
4. Remove the blank panel from the slots 2 and 4. 5. Attach the cover panel and secure it with the two screws. 1 2 3 1-4-3. Installing the HK-PSU04 The HK-PSU04 is used after it is installed in the MVE9000. c Before installing the HK-PSU04, be sure to turn off the main power. If the HK-PSU04 is installed while the main power is turned on, it can result in electrical shock or damage to printed circuit boards. 4 5 6 7 8 B3 x 5 Cover panel B3 x 5 Installation procedure 1.
1-5. Rack Mounting The MVE-9000 installs in a 19-inch standard rack. To mount the MVE-9000 in a rack, use the specified rack mount kit and follow the procedure described below. Specified rack mount kit : RMM-10 n If a rack mount kit other than the specified one is used, the unit may not be correctly install in a 19-inch standard rack. Parts of the RMM-10 . Rack tools . Right rack mount adaptor . Left rack mount adaptor . Rack tool attaching screws (B4 x 6 : 7-682-560-09) .
3. Attach the right and left adaptors to the rack completely using the specified six screws. (The illustration below shows the left adaptor.) 7. Fix the rack angles in the rack using the specified screws. Rack 31.75 B4 x 10 Rack angle 3U B4 x 10 31.75 B5 x 12 Unit : mm 4. Tighten the screws (B4 x 6 : two screws each on the right and left) for adjusting the length of the adaptor completely (the screws that were loosened in step 2). 5.
1-6. Matching Connectors and Cables Use the following connectors, cables or equivalents when connecting cables to the unit. Model name Panel indication Connector name Matching connector and cable Name MVE-9000 Sony part No.
1-7. Input/Output Signals of Connectors The input/output signals of the connectors at the rear panel are as follows. GPI, GPI2 : (D-sub 25-pin, Female) INPUT x 8, TTL OUTPUT x 4, relay contacts 30 V 0.1 A (resistive load) OUTPUT x 4, open collector 30 V rated voltage n indicates a controlling device. indicates a controlled device. REMOTE 1-4 : RS-422A (D-sub 9-pin, Female) (*1) 1 5 9 6 _ EXT VIEW _ Pin No.
1-8. Checks on Completion of Installation 1-8-1. On-board Switches Setting and LED Functions n The number shown in parentheses ( ) indicates the address on the circuit board. 1.
D602 (A-2) : PLL LOCK status LED REF IN signal format status indication. Lit when the REF IN signal matches with the switcher format setup. S101 (A-3) : Mode setting switch for the main CPU Sets the modes of the main CPU. Default setting when shipped from the factory is all OFF. D701 (A-2) : SBUS RX status LED S-BUS receive status indication. Lit while the data receive is in progress. S102 (A-2) : Group ID setting switch for LAN Sets the group ID for connecting LAN.
CN103 (A-4) : TERMINAL pin This pin is connected to the main CPU control terminal and used during maintenance. Conforms to RS-232C. CN401 (A-5) : TERMINAL pin This pin is connected to the IEEE1394 control terminal and used during maintenance. Conforms to IEEE1394. CN503 (A-5) : TERMINAL pin This pin is connected to the COM CPU-1 control terminal and used during maintenance. Conforms to RS-232C.
: COM CPU-1 : COM CPU-2 DI1 (green) (B-5) : CD (Card Detect) status LED Lit when the CPU-DK module is inserted correctly to the parent board. DI2 (green) (F-3) : RUN status LED Lit when the CPU-DK module starts operating. DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) (green) : STATUS1 to STATUS4 LED Used for maintenance purpose. Only the STATUS1 LED is lit in normal operation. : PC card D1 (A-1) : DETECT A Lit when the socket “A” is inserted correctly.
TP9 (C-3) : PERR signal check terminal PERR signal measuring terminal. TP10 (C-3) : SERR signal check terminal SERR signal measuring terminal. TP11 (B-1) : PAR signal check terminal PAR signal measuring terminal. D100 (B-1) : REF OK status LED Lit while V sync of the reference input is detected. D101 (B-1) : REF EXT status LED Lit while sync signal is input to the reference input. D200 (B-1) : LOCK status LED Lit while the machine is locked to the reference signal.
2.
D3704 (H-2) : SYSTEM status LED Lit when configuration is complete and FPGA reset is also complete. If the LED does not light, the FPGA may be defective. D3705 (H-5) : CN EXIST status LED CN-2357 board presence/absence status indication. Lit on the DVP-24A board that is installed in the same slot of CN-2357 board when CN-2357 board is present. D3706 (H-6) : CN POWER status LED The CN-2357 board power status indication.
TP501 (H-5) : +1.5 V-1 check terminal +1.5 V-1 measuring terminal. TP502 (H-5) : +2.5 V-1 check terminal +2.5 V-1 measuring terminal. TP503 (H-5) : +3.3 V check terminal +3.3 V measuring terminal. (G-2), (G-5) Refer to in “1. CA54CFA Board”. (G-2), (G-5) Refer to in “1. CA54CFA Board”. TP504 (H-5) : +1.5 V-2 check terminal +1.5 V-2 measuring terminal. TP505 (H-5) : +2.
3.
D3401, D3402, D3403, D3404 (A-10) : DBG7-4 status LED Used for design purpose. ND3401 (A-10), ND3402 (A-11) : STATUS LED VIF-28 board CPU status indication. S3201 (A-8) : CPU CONFIG switch Used for maintenance purpose. S3401 (A-10) : SETUP switch Used for maintenance purpose. CN3202 (A-7) : USB terminal Used for debugging. CN3203 (A-8) : TERMINAL pin This pin is connected to the sub CPU control terminal and used during maintenance. Conforms to RS-232C.
1-9.
Flow of Video Signals (MKE-9020M Installed) The figure below shows the flow of video signals in a MVS-8000 system.
Connection Example of the MVS-8000 System (MKE-9021M Installed) Reference video signal b) Ethernet switch a) Ethernet switch a) DATA REMOTE 1-4 MVE-9000-C DME Processor Pack CONTROL BVE-9100 Editing Control System Reference video signal b) DATA CTRL CTRL REMOTE 1 PERIPH REMOTE Reference video signal DATA b) MKS-8010 System Control Unit BKS-R Series HDS-X Series DCU-8000 Device Control Unit Pack PERIPH Reference video signal b) VTR DDR Audio Mixer MVS-8400/8300/8200 Switcher Processo
Flow of Video Signals (MKE-9021M Installed) The figure below shows the flow of video signals in a MVS-8000 system. MVE-9000-C DME Processor Pack V. K OUT V.
Section 2 Service Overview 2-1. Troubleshooting The main power cannot be turned on. (Indicator does not light green.) Flow1 The main power of the MVE-9000 cannot be turned on. (Indicator does not light green.) YES NO Is the POWER switch A of the MVE-9000 turned ON? Set it to ON. YES NO Is the power cord of the MVE-9000 connected correctly? Connect it correctly. YES The power supply unit is probably defective. The monitor picture is not displayed correctly.
2-2. Periodic Inspection and Maintenance 2-3. About the Data Backup Capacitor 2-2-1. Cleaning A large capacitor is installed on the CA-54CFA board in order to backup the memory storing the setup and other data in the MVE-9000. Leave the main power of the MVE9000 turned on for an hour or longer in order to charge this capacitor. The data is backed up for about a week when the capacitor is fully charged under normal operating temperature.
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation. Le matériel contenu dans ce manuel consiste en informations qui sont la propriété de Sony Corporation.
MVE-9000-C (SY) E 3-790-017-01 Sony Corporation B&P Company Printed in Japan 2003.