2-190-706-13 (1) Digital Powered Mixer Operating Instructions Before operating the unit, please read this manual thoroughly and retain it for future reference.
Important Safety Instructions • • • • • • • Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. • Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Table of Contents Overview.................................................................................6 Features ...................................................................................... 6 The SRP-X500P manuals........................................................... 6 Using the supplied CD-ROM..................................................... 6 Operating Conditions............................................................ 7 Precautions ..............................................
Connector specifications .......................................................... 32 Troubleshooting ..................................................................
Overview Features The SRP-X500P is a versatile powered mixer which incorporates an audio mixer, RGB/video switcher, processor, and power amplifier into a 3U-rack-size unit. external personal computer or system controller to control the SRP-X500P. • REMOTE PARALLEL connector Input signal selection, volume control and scene control of the SRP-X500P can be performed via the input pins.
SRP-X500P Manager This is a program for setting the SRP-X500P parameters from a PC. The English and the Simplified Chinese versions are provided. Operating Conditions How to open files The recommended operating environment for using the SRP-X500P Manager is as follows. 1 2 Insert the supplied CD-ROM into the CD-ROM drive, then click “My Computer.” OS Microsoft Windows Millennium Edition Microsoft Windows 2000 Professional Microsoft Windows XP Professional Double-click “SRP-X500P.
Precautions • The SRP-X500P must be used within a temperature range of 0°C to 40°C (32°F to 104°F). • Operating the SRP-X500P near electrical equipment (motors, transformers, or dimmers) may cause it to be affected by electromagnetic induction. Keep the SRPX500P as far from such equipment as possible. • The presence of the lighting equipment may produce electrical interference over a very wide frequency range.
Location and Function of Parts Front panel 1 2 3 qk qj 45 6 qh qg qf qd 7 qs qa q; 8 9 (In the figure above, the two blank panels are removed.) A POWER switch Turns the SRP-X500P on and off. With the SRP-X500P Manager software, you can set a parameter that will cause the projector or display monitor connected to the SRP-X500P to turn on or enter standby status when the POWER switch is pressed.
MIC 3: Adjusts the level of the signal input from the MIC INPUT 3 connector. MIC 4: Adjusts the level of the signal input from the MIC INPUT 4 connector. LINE: Adjusts the level of the signals input from the LINE IN connectors. AV/RGB: Adjusts the level of the signals input from the AV/RGB INPUT audio connectors, as specified by the J AV/RGB SELECT buttons. I MASTER control Adjusts the output level of the assigned channels.
Note For control of an LCD Data Projector VPL-PX15, use the CONTROL S connectors instead of the PROJECTOR CONTROL RS-232C connector. N SYSTEM TYPE selector Can be set to positions 1-9, according to the speaker configuration of the AV system being used. (Select position 0 only when setting the system type using the SRP-X500P Manager software.) The setting becomes effective next time the power is turned on. Thus, change the setting while the SRP-X500P is turned off.
Rear panel 1 2 3 4 5 1 6 7 3 # 3 # 3 # 3 # 3 # qf qd qs qa 9 8 A ANT IN a/b connectors (BNC type) Connect antennas for the tuner unit installed in the SRPX500P. Only the supplied antennas or the UHF Antenna AN-820 (not supplied) can be used. B PROJECTOR CONTROL CONTROL S IN/OUT connectors (stereo mini jack) Used to control the LCD Data Projector VPL-PX15 exclusively. Notes For details on the function of this connector, see “PROJECTOR CONTROL CONTROL S IN/OUT connectors” (page 24).
Input pins Connectable device Remarks Switch - Volume With 10 kΩ , B-curve Emergency broadcast Connected via relay system K AV/RGB INPUT audio connectors (A to E) (phono jack) Connect to the audio output connectors of the devices whose video output is connected to the N AV/RGB INPUT video connectors on the SRP-X500P.
that of the tuner unit, or that the battery in the microphone is running down. Installation To remove the tuner unit Pull the latch securing the tuner unit to the side and pull out the tuner unit. Installing the tuner units Up to two WRU-806 UHF Synthesizer Tuner Units (not supplied) or two URX-M1 Tuner Units included in the UWP-X1/X2 (not supplied) can be installed in the SRPX500P.
Note When removing the blank panels to the SRP-X500P, be sure to start with the small panel. Rack mounting GP button + button CH button – button RF indicator About the rack Use an EIA-standard 19-inch rack with a depth of 450 mm or more. Use four screws of the same diameter as the rack screw holes and with an effective length of 12 mm or more to mount the SRP-X500P into the rack. Rack 1 Turn on the SRP-X500P. 2 Press and hold down the GP button, and press the + or – button to select a group.
Releasing the buttons automatically cancels the group and channel selection mode, and the currently displayed group is selected. Refer to “Wireless Microphone System Frequency List” supplied with the WRU-806. 3 Press and hold down the CH button, and press the + or – button in 3 seconds to select a channel. Similer to step 2, each time you press the + or – button, the CH indication changes in the order shown in the group and reception channel list.
System Configurations and Speaker Connections Sample configuration using the SRP-X500P factory-settings In this configuration, the SRP-X500P can be used without having to change the settings with the supplied SRP-X500P Manager software.
Sample system configuration with a custom operation panel and environmental equipment connected In this configuration, the SRP-X500P can be controlled by a custom operation panel or an external system controller.