12.5 PERPENDICULARITY BETWEEN SIGHT OF VIEW & HORIZONTAL AXIS
(2C)
Inspection
1. Set object A at a far distance at the same
height as the instrument, leveling the instrument
and turn on the power (eg. HL=10°1310).
2. Sight object A in horizontal left and read value
of HA. (eg. HR= 190°1340).
3. Loosen the vertical and horizontal tangent unit
and rotate the telescope. Sight object A in
horizontal right and read the HA.
4. 2C =HL-HR±180°=-30≥±20, overrange. So
it is necessary to adjust 2C.
Adjustment
1.Use the horizontal tangent screw to adjust the
reading of HA.
HR+C = 190°1340 15” = 190°13’25”
2. Take off the cover of the reticle between the
eyepiece and focusing screw. Adjust the two
adjusting screws, loosening one screw and
tightening the other one. Move the reticle to
sight object A exactly.
3. Repeat inspection and adjustment until
|2C|<20. Then replace the cover of the reticle.