User's Manual

60
Inspection
1. After leveling the instrument, collimate at any
target A in HL. Record the value as L.
2. Rotate the EDM and aim at the target A in HR.
Record the value as R.
3. If the vertical 0°in zenith, I =(L + R - 360°)/2. If
the vertical 0 in horizon, I= (L + R - 180°)/2 or (L +
R - 540°)/2.
5. If |i| 10”, it need to reset the Vertical 0.
Adjustment
1. Aim at target A in same height with the
instrument in HL.
2. Aim at the same target A on HR.
3. After setting the angle in both HL and HR, it will
display the index difference, press [Reset] to
confirm the adjustment.
4. Repeat the inspection steps to check the
Index Difference (i angle). If the difference still
cannot meet the requirement, please check
whether the steps you did are correct. Then reset
again.
5. If the Index Difference still fails to meet the
requirement after repeated operation, the
instrument should be returned to our authorize
service center for inspection and repair.
Note: The value of vertical angle is not adjusted and
compensated, just for a reference in adjustment.