Installation Guide

SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
7/27/15 Visit us on the web at www.speakman.com 92-S-3661-R6
SPEAKMAN
®
S-3661, S-3661-CA, S-3661-CA-E Installation, Maintenance &
Operation Instructions
Single Lever Deck Mounted Sink Fitting
DESCRIPTION
Speakman polished chrome plated, NSF compliant, vandal resistant, single lever faucet. Long-life ceramic
cartridge. Adjustable temperature limit and flow control. Brass body constructions, metal handle with color-coded
index. 8” spread brass gooseneck, swivel or rigid. Water conserving vandal-resistant flow control reduces flow to
1.5 GPM/5.7 LPM maximum to meet existing ANSI A112.18.1 Standard. 3/8 compression threaded inlets for
standard hose connections.
SPECIFICATIONS
SUPPLY: 3/8 COMPRESSION (9/16-24 THREAD)
FLOW RATE: 1.5 GPM / 5.7LPM MAX
SHIPPING WEIGHT: 4.6 lbs.
STATIC PRESSURE: 20-80 PSI
INSTALLATION
1) Shut off hot and cold water supplies. Remove old fixture to be replaced and clean mounting surface.
2) Place the rubber o-ring mounting seal on the bottom groove of the valve body. Slip the valve body through
the counter.
3) From underneath the counter, slip the cup washer onto mounting rod and secure with the mounting nut.
Use the spacer for thin sink applications.
Note: The outlet/supply tubes can be bent slightly to allow access to tighten the mounting nut.
Warning: Do not kink the tubes. Kinked tubes will void warranty.
4) Set spout base on the counter and position. From underneath the counter, slip the cup washer onto the
spout base inlet and secure with the mounting nut.
5) Connect water supply lines to inlets of the valve body. Also connect the valve body outlet to the inlet of the
gooseneck with the hose provided. Use 2 wrenches when tightening all body connections.
Warning: When tightening the connections hold the valve body connection while turning the swivel
hose/riser connections.
6) From above sink, install the spout. For All Swiveling Spout: Install spout assembly into the body outlet and
wrench tighten spout collar nut. Do not use the spout locking washer. For Rigid Spout: Place the spout
locking washer into the body outlet, install the spout assembly, position, and wrench tighten the spout
collar nut. For Rigid Vacuum Breaker Spout- VB6/8 (Less “SW” option): Do not use the spout locking
washer. IMPORTANT- First install rigid adapter in body and wrench tighten (See Rough-In on back side of
sheet). Apply thread locker/sealant to the spout tapered pipe threads. Screw the spout into the adapter
until the threads start to get snug. Note- When positioning the spout, hold adapter hex with a wrench, so
body does not move. Holding the hex of the adapter with a wrench, tighten the spout at least 1/3 turn to
the proper position (Do not over tighten spout). Remember that the thread locker/sealant will lock and seal
the spout assembly in place.
7) If applicable, install hose and spray holder to sink/countertop. From above sink, insert inlet end of hose
through holder. Working from under the sink, connect hose inlet to hose and spray outlet of deck body.
Wrench tighten.
8) Turn water supplies on and flush out the fitting. Install outlet device (If applicable) and check all
connections for leaks.
OPERATION
Simply lift the handle up. Rotating the handle will change water temperature.