Even though this generator has an overall rated wattage of 4000, do not attempt to draw more than 3500 Watts from the 120 Volt outlet.
Draws higher than 3500 Watts will damage this generator and void the warranty.
NOTE: While this generator is running, power is available from either the standard 120 Volt outlet or the 12 Volt DC outlet. Both 120 Volts and 12
Volts can be simultaneously drawn from this generator.
Turn on the connected electrical devices beginning with the device with the highest rated wattage requirement and then each additional device with
the next lower rated wattage requirement.
Do not connect 50Hz or 3-phase loads to this generator.
DC Usage
The DC outlet is for charging 12 Volt battery, up to 8 Amps.
NEVER attempt to jumpstart a car with this generator.
Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency.
To Plug Items Into the Generator
1. Allow the engine to run for several minutes after it has been started.
2. Confirm that the electrical device is switched off prior to plugging it into this generator.
4. Turn on the connected electrical devices beginning with the device with the highest rated wattage requirement and then each additional device
with the next lower rated wattage requirement.
SOME NOTES ABOUT POWER CORDS
Long or thin cords can require more wattage from a generator to power an electrical device. Figure 6 shows the recommended cords according to
the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly
higher rated wattage requirement.
Device Requirements
Max. Cord Length (ft) by Wire Gauge
Amps
Watts (120V)
Watts (240V)
#8 wire
#10 wire
#12 wire
#14 wire
#16 wire
2.5
300
600
NR
1000
600
375
250
5
600
1200
NR
500
300
200
125
7.5
900
1800
NR
350
200
125
100
10
1200
2400
NR
250
150
100
50
15
1800
3600
NR
150
100
65
NR
20
2400
4800
175
125
75
50
NR
25
3000
6000
150
100
60
NR
NR
30
3600
7200
125
65
NR
NR
NR
40
4800
9600
90
NR
NR
NR
NR
Figure 6 - Maximum Extension Cord Lengths by Power Requirement
SWITCHING BETWEEN GASOLINE & PROPANE FUEL
In order to switch between gasoline and propane fuel, you must turn off the current fuel. For example, if using gasoline and you want to switch to
propane, turn the gasoline Fuel Petcock to OFF position and let the engine continue to run until it burns off all remaining gasoline fuel in carburetor.
Then turn the propane tank ON. If using propane and you want to switch to gasoline, turn the propane tank OFF and turn the gas Fuel Petcock ON.