Lacey Act Declaration Form

IN018 Rev V 0120 63 Saber Way, Ward Hill, MA 01835 | spruce.com
Mounting: Mounting bracket included.
Recommended Ducting: 4”, 6”, 8” or 10” Rigid or Flexible Ducting
Storage Temperature Range: 32-100 degrees F.
Continuous Duty: 3000 RPM
Thermally Protected: Class F Insulation [RB190 Class B]
Rated for Indoor use only
Rated for Residential and Commercial use
Suitable for use with solid state speed controls
Suitable for use over tub or shower
The following chart shows fan performance for RB Series Commercial/Residential Fans:
RB SERIES PRODUCT SPECIFICATIONS
Typical CFM vs. Static Pressure "WC
Power Consumption @ 120 VAC, 60Hz (2.0 Amp Maximum)
Size Chart
RB110 ONLY
RB110 130 c (266 F)
RB190
130 c (266 F)
RB275 150 c (302 F)
RB300 150 c (302 F)
RB350 150 c (302 F)
RB400 150 c (302 F)
Thermal Cutout
0" .2" .5" .75" 1.0" 1.25" 1.5" 1.75" 2.0"
RB110 121 100 68 20 - - - - -
RB190 158 148 140 135 109 53 33 - -
RB275 251 210 157 117 70 26 - - -
RB300 318 270 211 170 135 87 30 - -
RB350 334 299 247 210 176 142 116 87 52
RB400 531 490 415 340 268 200 139 84 41
Fan Model "A" Dim "B" Dim "C" Dim Duct Size Weight L.2
RB110 9.7" 3.9" 8.5" 4" 5 lbs 30 ft
RB190 9.7" 3.9" 8.5" 4"
6.2 lbs. 35 ft
RB275 11.8" 5.9" 9" 6" 5.5 lbs 48 ft
RB300 13.4" 5.9" 9" 6" 8 lbs 40 ft
RB350 13.4" 5.9" 9" 6" 8.5 lbs 30 ft
RB400 13.4" 7.9" 10.5" 8" 11.5 lbs 57 ft
RB110 14-20 watts
RB190 46-62 watts
RB275 47-65 watts
RB300 66-87 watts
RB350 91-129 watts
RB400 96-138 watts
L.2= Estimated Equivalent Length of Rigid Metal Ducting resulting in .2in WC pressure loss for Duct
Size listed. Longer Equivalent Lengths can be accommodated at Flows Lower than that at .2in WC
pressure loss (see CFM Vs Static Pressure “WC Table). Do not operate fan above 80% of maximum
Static Pressure per performance table.