Energy Guide

© 2019 Schneider Electric
All Rights Reserved
3-17
www.se.com/us
Accessories and Special Features Heavy Duty Safety Switches
Class 3110 / Refer to Catalog 3100CT1602
Table 3.32 Internal Barrier Kits (cont'd.)
Cat. No.
Description Safety Switch Application
[70]
SS80120LI
HDSS Line Side Interior Barrier for
800 1200 A Safety Switch
[71]
800 1200 A
SS80120LO
HDSS Load Side Interior Barrier for 800
1200 A
Safety Switch
[70]
800 1200 A
Fuse Puller Kits
Fuse Puller Kits
Fuse Puller Kits are standard equipment on the following 30 A - 100 A switches: NEMA
Type 12 and 12K, NEMA Type 4/4X/5 stainless steel, NEMA Type 4X fiberglass
reinforced polyester and Krydon
TM
.
Fuse Puller Kit available for field installation on NEMA Type 1 and NEMA Type 3R, 30 A
100 A switches. One Fuse Puller Kit required for a 3 pole fusible 240 V or 600 V heavy
duty switch. Fuse Puller Kits can be field installed on switches manufactured since
February 1980.
Amperes Series Number [72]
Fuse Puller Kit Cat. No.
30 F5–F7
FPK03 [73]
60
60
F5–F7 (600 V)
F5 (240 V)
FPK0610
FPK03
100 F5–F7 FPK0610
Solid Neutral Assembly Kits
Table 3.33: Solid Neutral Assembly Kits[74] [75] [76] [77]
Amperes Series Number [78] Standard Neutral Kit Cat. No. Terminal Data
AWG/kcmil
Optional Copper Only
Neutral Kit Cat. No.
Terminal Data
AWG/kcmil
30 F5–F6
SN03 [79]
(2) 14-3 Al/Cu plus
(1) 14-3 Al/Cu Svc Ground
SN03C [79]
(2) 14-6 Cu plus
(1) 14-6 Cu Svc Ground
60
F5–F6,
(600 V)
SN0610
(2) 14-1/0 Al/Cu plus
(2) 14-6 Al/Cu Svc Ground
SN0610C
(2) 14-1/0 Cu plus
(2) 14-6 Cu Svc Ground
F5–F6
(240 V)
SN03
(2) 14-3 Al/Cu plus
(1) 14-3 Al/Cu Svc Ground
SN03C
(2) 14-1/0 Cu plus
(2) 14-6 Cu Svc Ground
100
F5–F6,
SN0610
(2) 14-1/0 Al/Cu plus
(2) 14-6 Al/Cu Svc Ground
SN0610C
(2) 14-1/0 Cu plus
(2) 14-6 Cu Svc Ground
200 [80]
F5–F6 SN20A
(2) 6-250 Al/Cu plus
(1) 14-10 Al/Cu Svc Ground
SN20C
(2) 6-250 Cu plus
(1) 14-1/0 Cu Svc Ground
400 and 600 E4–E5 H600SN
(4) 1-750 Al/Cu plus
(1) 4-300 Al/Cu Svc Ground
H600SNC
(2) 1-600 Cu and
(2) 4-350 Cu plus
(2) 6-250 Cu Svc Ground
800 E4 H800SNE4
(6) 3/0-750 Al/Cu plus
(2) 6-350 Al/Cu Svc Ground
1200 E4 H1200SNE4
(8) 3/0-750 Al/Cu plus
(2) 6-350 Al/Cu Svc Ground
3
SAFETY SWITCHES
[70] Requires line side barrier kit.
[71] Requires arc shield on 240 V switches be changed to 600 V arc suppressor. Contact the Customer Care Center at 1–888–778–2733 fo the arc suppressor part number.
[72] For series not shown in chart refer to the switch wiring diagram.
[73] 30 A 4 pole, H361-2 and H361-2RB Series F5, H361WA and H361WC Series F6 use FPK0610.
[74] For series not shown in chart refer to the switch wiring diagram.
[75] For solid Neutral Assembly Kits for Krydon
TM
enclosure see Table 3.20.
[76] For Solid Neutral Assembly Kits for Fiberglass Reinforced Ployester enclosures see Table 3.19.
[77] Neutrals cannot be installed in 4 or 6 pole switches or receptable switches.
[78] See page 3-22 and page 3-23 for safety switch series.
[79] The following 30 A Series F5-F6 switches use SN0610 or SN0610C: H3612, H3612RB, H3612A, H3612AWK, HU3612, HU3612RB, HU3612A and HU3612AWK.
[80] For 200% neutral, order (2) SN20A Neutral Kits and (1) SN20NI Neutral Jumper Kit.
9/13/2019