Heavy Duty Safety Switches 240 Volt—Single Throw Fusible Switches
www.se.com/us
Class 3130 / Refer to Catalog 3100CT1602
Heavy Duty Safety Switches
NEMA Type 1 NEMA Type 3R
NEMA Type
4, 4X, 5
Stainless Steel
NEMA Type 12
Visible blade heavy duty safety switches are designed for application where maximum
performance and continuity of service are required. All heavy duty safety switches
feature quick-make, quick-break operating mechanism, a dual cover interlock and a color
coded indicator handle. They are suitable for use as service equipment when equipped
with a field- or factory-installed neutral assembly or equipment grounding kit, unless a
600Y/347 V or 480 Y/277 V, 1000 A or greater, solidly grounded WYE system is used,
per NEC 230-95. Heavy duty safety switches are UL Listed (except as noted). Files
E2875 and E154828 meet or exceed the NEMA Standard KS1. For UL Listed short
circuit current ratings, see UL Listed Maximum Short Circuit Current Ratings-AC only,
page 3-11.
Table 3.13: 240 Volt—Single Throw Fusible
System Amperes
NEMA
Type 1
Indoor
NEMA Type 3R
Rainproof
(Bolt-on Hubs
[1])
NEMA Type
4, 4X, 5, [2]
304 Stainless
Steel [3]) Dust
tight, Watertight,
Corrosion
Resistant
(Watertight Hubs
[1])
NEMA Type 12K
With
Knockouts
(Watertight
Hubs [1])
NEMA Type
3R, 5 or 12 [4]
Without
Knockouts
(Watertight
Hubs [1])
Horsepower Ratings
240 Vac
250 Vdc
[5]
Std.
(Using Fast
Acting,
One Time Fuses)
Max.
(Using Dual
Element, Time
Delay Fuses)
Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
2-Wire (2 Blades and Fuseholders)—240 Vac, 250 Vdc
  30
Use three-wire devices
For two-wire applications
H221DS H221A H221AWK 1-1/2
 3 [6]
 3
  7-1/2 [6]
 5
  30
H2212AWK [7]
1-1/2  3  5
  60 H222DS H222AWK  3
 7-1/2 [6]
10
 15 [6]
10
 100 H223DS H223A H223AWK 7-1/2
15 [6]
15
 30 [8]
20
 200 H224DS H224A H224AWK 15
25 [6]
 60 [6]
40
 400 H225 H225R H225DS H225AWK 50
 600 H226 H226R H226DS H226AWK
75 [6]
200 [6]
50
 800 H227 H227R H227AWK 50 50
1200 H228 H228R H228AWK 50 50
3-Wire (2 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc
  30 H221N H221NRB
Use two-wire devices,
See Field-Installed Neutral Assemblies, page 3-17
   1-1/2
 3 [6]
 3
  7-1/2 [8]
 5
  60 H222N H222NRB 3
 7-1/2 [6]
10
 15 [6]
10
 100 H223N H223NRB 7-1/2
15 [6]
15
 30 [6]
20
 200 H224N H224NRB 15
25 [6]
 60 [6]
40
 400 H225N H225NR H225NDS H225NAWK
50 [6]
125 [6]
50
 600 H226N H226NR H226NDS H226NAWK
75 [6]
200 [6]
50
 800 H227N
H227NR [9]
H227NAWK 50 50
1200 H228N
H228NR [9]
H228NAWK 50 50
3-Wire (3 Blades and Fuseholders)—240 Vac, 250 Vdc
  30
Use four-wire devices
For three-wire applications
H321DS H321A H321AWK 1-1/2   3   3   7-1/2  5
  60 H322DS H322A H322AWK  3   7-1/2 10  15 10
 100 H323DS H323A H323AWK 7-1/2  15 15  30 20
 200 H324DS H324A H324AWK 15  25  60 40
 400 H325 H325R H325DS H325AWK  50 125 50
 600 H326 H326R H326DS H326AWK  75 200 50
 800 H327
H327R [9]
H327AWK 50 100 250 50
1200 H328
H328R [9]
H328AWK 50 100 250 50
4-Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc
  30 H321N H321NRB
Use three-wire devices,
See Field-Installed Neutral Assemblies, page 3-17
1-1/2   3  3     7-1/2  5
  60 H322N H322NRB 3     7-1/2 10  15 10
 100 H323N H323NRB 7-1/2  15 15  30 20
 200 H324N H324NRB 15  25  60 40
 400 H325N H325NR H325NDS H325NAWK  50 125 50
 600 H326N H326NR H326NDS H326NAWK  75 200 50
 800 H327N
H327NR [9]
H327NAWK 50 100 250 50
1200 H328N
H328NR [9]
H328NAWK 50 100 250 50
4-Wire (4 Blades and Fuseholders)
 30
Use 600 Vac devices. See 600 Volt—Single Throw Fusible Switches, page 3-9.
 60
100
200
400
600
Accessories: see page 3-15
Dimensions: NEMA Type 1 and 3R, see page 3-22
Dimensions: NEMA Type 4, 4X and 5 Stainless and NEMA Type 12, see page 3-23
3
SAFETY SWITCHES
[1] For Rainproof Bolt-On Hubs and Watertight Hubs see Hubs, page 3-15.
[2] Complete rating is NEMA Type 3, 3R, 4, 4X, 5 and 12. For NEMA Type 3R applications, remove drain screw from bottom endwall.
[3] See 316 Grade Stainless Steel—NEMA Type 3, 3R, 4, 4X, 5, 12, page 3-12.
[4] Also suitable for NEMA Type 3R application by removing drain screw from bottom endwall.
[5] For switching dc, use two outside switching poles.
[6] For corner grounded delta systems, use switching poles for ungrounded conductors. See data bulletin 2700DB0202 for additional information.
[7] 60 ampere switch with 30 ampere fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks.
[8] For corner grounded delta systems, use switching poles for ungrounded conductors.
[9] Suitable for NEMA Type 5 applications with drain screw installed.