Table of Contents Section 7 Miniature and Molded Case Circuit Breakers Selection Information B-Frame 7-1 QO™ and QOU Miniature Circuit Breakers 7-11 Homeline™ Miniature Circuit Breakers 7-19 Multi 9™ Miniature Circuit Breakers 7-23 PowerPact™ Molded Case Circuit Breakers 7-29 Mission Critical Circuit Breakers 7-42 500 Vdc Circuit Breakers 7-43 Automatic Switches 7-44 Motor Circuit Protectors 7-45 PowerPact™ Circuit Breaker Accessories 7-49 Micrologic™ Electronic Trip Units 7-59 Maste
Selection Information Miniature Circuit Breakers Class 500, 600 www.se.
Miniature Circuit Breakers Selection Information Class 500, 600 www.se.
Selection Information Miniature Circuit Breakers Class 500, 600 www.se.com/us HOM Circuit Breakers HOM Circuit Breakers Circuit Breaker Type Plug-on Bolt-on Unit Mount Number of Poles Current Range (A) Interrupting Ratings UL/CSA Rating (kA) (50/60 Hz) DC Ratings IEC 60947-2 (50/60 Hz) [21] Special Ratings CCC Fed.
Miniature Circuit Breakers Selection Information Class 500, 600 www.se.com/us Multi 9, EDB Miniature Circuit Breakers Multi 9™ Circuit Breakers and Supplementary Protectors Circuit Breaker Type Plug-on Bolt-on DC Ratings 3 0.5–63 — — UL1077 C60SP [25] 1 2 0.
Selection Information Molded Case Circuit Breakers Class 500, 600, 800 www.se.
Molded Case Circuit Breakers Selection Information Class 500, 600, 800 www.se.com/us PowerPact™ Q-Frame, Q4, LA, LH, L-Frame Molded Case Circuit Breakers Current Range (A) Interrupting Ratings 240 Vac UL/CSA/ 480Y/277 Vac NOM AC Rating 480 Vac (kA RMS) 600Y/347 Vac (50/60 Hz) 600 Vac 250 Vdc [43] UL/CSA/ NOM DC 500 Vdc [44] Ratings [43] 220/240 Vac IEC AC 380/415 Vac Rating (kA RMS) 440/480 Vac (50/60 Hz) 500/525 Vac Icu/lcs [45] 690 Vac IEC DC 250 Vdc Ratings 500 Vdc Special Ratings CCC Fed.
Selection Information Molded Case Circuit Breakers Class 600, 612, 800 www.se.com/us M-, P-, and R-Frame Molded Case Circuit Breakers PowerPact 800 A M-Frame Circuit Breaker Type Number of Poles Current Range (A) Interrupting Ratings UL/CSA/NOM Rating (kA RMS) (50/60 Hz) DC Ratings 240 Vac 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac 250 Vdc 500 Vdc [51] 240 Vac 7 IEC (kA RMS) (50/60 Hz) 415 Vac Icu/Ics [52] Special Ratings CCC Fed.
Insulated Case Circuit Breakers Selection Information Class 600, 800 www.se.
Selection Information Insulated Case Circuit Breakers Class 600, 800 www.se.
QO Plug-On Circuit Breakers QO™ and QOU Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us QO Standard Plug-On Circuit Breakers Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD and NQ panelboards, NQOD and NQ OEM interiors or Speed-D™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD and NQ panelboards or interiors.
QO™ and QOU Miniature Circuit Breakers QO Plug-On Circuit Breakers Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us QO/QOB Ring Terminal Table 7.2: QO/QOB Ring Terminal—Factory-Installed Only Ampere Rating 10–30 A 35–60 A 35–50 A 70–110 A 60–100 A Poles 1, 2, 3 1,2 3 2 3 Suffix 5237 5238 5273 Wire Sizes for QO/QOB Circuit Breakers Table 7.
QO Plug-On Circuit Breakers QO™ and QOU Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.se.com/us QO Arc-Fault Circuit Breaker (QO-CAFI) QO arc-fault circuit breakers provide protection for Series and Parallel Type Arcing as required by the NEC and local code adoption, and comply with UL1699. Table 7.
QO™ and QOU Miniature Circuit Breakers QO Plug-On Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.se.com/us QO Switch Neutral Common Trip Circuit Breakers (QO-SWN) Switch Neutral Common Trip 2008 NEC® 514.11 Table 7.
Accessories QO™ and QOU Miniature Circuit Breakers Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Accessories for QO/QOB Circuit Breakers Table 7.15: Accessories for use with QO and QOB Miniature Circuit Breakers Description Cat. No.
QO™ and QOU Miniature Circuit Breakers QO™ Mounting Bases Class 652 / Catalog 0730CT9801, 0860CT0201 www.se.com/us QO Mounting Bases Table 7.17: QO OEM Mounting Bases—UL Recognized Components Main Lug 1P Mounting Bases Main Wire Size Max. No. Rating Spaces Cat. No. AWG/kcmil 1P QO Plug-On Mounting Bases—For unit mounting QO, QO-GFI, QO-AFI and QO-EPD circuit breakers 14–4 Cu, 12–3 Al QON2L70 70 A 2 2 125 A 4 4 SK9948BW 12–1/0 Cu/Al 125 A 4 4 SK9842 12–1/0 Cu/Al 1Ø2W 240 Vac Max.
QOU Miniature Circuit Breakers / QYU Supplementary Protectors QO™ and QOU Miniature Circuit Breakers Class 720 / Refer to Catalog 0730CT9801 www.se.com/us Low Ampere QOU Miniature Circuit Breakers QOU unit mount miniature circuit breakers (cable-in/cable-out) are ideal for OEM applications. They have the Square D™ circuit breaker’s unique Visi-Trip™ feature and can be DIN rail-mounted or surface- or flush-mounted using mounting feet. Mounting feet not provided [25].
QO™ and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers / QYU Supplementary Protectors Class 720 / Refer to Catalog 0730CT9801 www.se.com/us High Ampere QOU Circuit Breakers General Specifications Common to All High Ampere QOU Circuit Breakers • Flush mount, surface mount, and DIN rail mount. • Internal common trip. • Non-reversible line and load lugs. • Terminal lug wire size (1) 12– 2/0 AWG Cu or Al. • UL Listed 60 Vdc per pole (5 k AIR).
QOU Accessories Homeline™ Miniature Circuit Breakers Class 720 / Refer to Catalog 0730CT9801 www.se.com/us QOU Accessories Table 7.25: Accessories for QOU Low Ampere Circuit Breakers (Except as Noted) Description QOU14100JBAF Factory-installed ring tongue terminal, 10–32 screw, for 1P, 2P, 3P QOU, 10–60 A Hex drive 5/32 in.
Homeline™ Miniature Circuit Breakers Plug-On Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Standard Plug-On Circuit Breakers The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers. Table 7.
Plug-On Circuit Breakers Homeline™ Miniature Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Ground-Fault Circuit Breaker (HOM-GFI) HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. Table 7.
Homeline™ Miniature Circuit Breakers Plug-On Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Circuit Breaker Wire Sizes Table 7.
C60BP and C60BPR Circuit Breakers Multi 9™ Miniature Circuit Breakers Class 860 / Refer to Catalog LVCATM9OEM_EN www.se.com/us Multi 9 C60BP and C60BPR Miniature Circuit Breakers C60BP and C60BPR are multi-standard miniature circuit breakers and branch circuit protection as defined by UL489.
Multi 9™ Miniature Circuit Breakers C60SP Circuit Breakers Class 860 / Refer to Catalog LVCATM9OEM_EN www.se.com/us Multi 9 C60SP Miniature Circuit Breakers C60SP circuit breakers are multi-standard miniature circuit beakers and supplementary protection as defined by UL1077. They combine the following functions: • circuit protection against short-circuit curves • circuit protection against overload currents • tripping and fault indication by the addition of auxiliary accessories IEC UL1077 / CSA C22.
C60H-DC Circuit Breakers Multi 9™ Miniature Circuit Breakers Class 860 / Refer to Catalog LVCATM9OEM_EN www.se.com/us Multi 9 C60H-DC Miniature Circuit Breakers for DC Circuits IEC UL1077, IEC/EN 60947-2, GB14048.2 Multi 9 Miniature Circuit Breakers C60H-DC circuit breakers are multi–standard miniature circuit beakers and supplementary protection as defined by UL1077, dedicated to direct current applications.
Multi 9™ Miniature Circuit Breakers Multi 9 Circuit Breakers Busbar Offer Class 860 / Refer to Catalog LVCATM9OEM_EN www.se.com/us C60BP (UL489) Comb Busbars These comb busbars are aimed to be used only with C60BP circuit-breakers. They perform distribution and subdistribution of the electric power supply and allow rapid assembly and disassembly of equipment. IEC Table 7.
Multi 9 Circuit Breakers Busbar Offer Multi 9™ Miniature Circuit Breakers Class 860 / Refer to Catalog LVCATM9OEM_EN www.se.com/us C60SP (UL1077) Comb Busbars The comb busbars are used only for C60SP circuit breakers UL 1077 supplementary protection in conformity with standards: • UL 1077 / CSA C22.2 No. 235 / IEC 60947-2 / GB 14048-2. IEC They perform distribution and subdistribution of the electric power supply and allow rapid assembly and disassembly of equipment. Table 7.
Multi 9™ Miniature Circuit Breakers C60 Accessories Class 860 / Refer to Catalog 0860CT0201 www.se.com/us Multi 9 C60 Accessories Electrical Accessories for C60 Circuit Breakers and Supplementary Protectors Possible Combinations Mounted to the left of the circuit breaker with a maximum width of 54 mm.
PowerPact Family PowerPact™ Molded Case Circuit Breakers Class 611, 612 www.se.com/us The PowerPact Advantage • • • • • B-Frame 125 A H-Frame 150 A Electronic Trip Version J-Frame 250 A Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial applications. Smart: Integrated metering options provide a cost-effective solution to reduce energy consumption, optimize energy costs, and improve energy availablility for your facilities.
PowerPact™ Molded Case Circuit Breakers B-Frame Circuit Breakers Class 0613 www.se.com/us PowerPact B-Frame Molded Case Circuit Breakers (125 A) PowerPact B-frame circuit breakers provides economical thermal-magnetic circuit protection in a compact size.
H- and J-Frame Circuit Breakers PowerPact™ Molded Case Circuit Breakers Class 611 / Refer to Catalog 0611CT1001 www.se.com/us PowerPact H- and J-Frame Molded-Case Circuit Breakers (150 A and 250 A) A flexible, high performance offer certified to global standards.
PowerPact™ Molded Case Circuit Breakers H- and J-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT1001 www.se.com/us PowerPact H-Frame Thermal-Magnetic Circuit Breakers Table 7.
H- and J-Frame Circuit Breakers PowerPact™ Molded Case Circuit Breakers Class 611 / Refer to Catalog 0611CT1001 www.se.com/us 0 >11 % Ir .9 4 .9 5 .9 6 .9 7 .9 3 .9 8 .9 2 .9 1 Ir 4( x Io ) 5 3 6 2 .5 8 2 10 1 .5 x Is d( H-Frame Micrologic™ Trip Unit M icor lo g ic >30 A >30 5 .2 E PowerPact H- and J-Frame Electronic Trip Current Limiting Circuit Breakers (150 A and 250 A) Ir ) H-Frame Circuit Breaker Optional FDM and IFM Module J-Frame Micrologic Trip Unit Table 7.
PowerPact™ Molded Case Circuit Breakers Q/LA/LH/Q4-Frame Class 0734 / Refer to Catalogs: 0734CT0201 www.se.com/us Q-Frame Molded Case Circuit Breakers (250 A) PowerPact Q-frame circuit breakers are used for overcurrent protection and switching on 240 Vac applications.
Q/LA/LH/Q4-Frame PowerPact™ Molded Case Circuit Breakers Class 0734 / Refer to Catalogs: 0734CT0201 www.se.com/us Q4-Frame Molded Case Circuit Breaker (400 A) • • • • Thermal magnetic protection from 250 A up to 400 A at 240 Vac 2- and 3-pole unit mount and I-Line constructions 25 kA at 240 Vac UL interrupting rating UL, CSA and IEC certified NOTE: Consider using PowerPact™ circuit breakers for situations requiring circuit breaker accessories. See PowerPact Accessories, page 7-49 for more information.
PowerPact™ Molded Case Circuit Breakers PowerPact L-Frame Electronic-Trip Circuit Breakers Class 611 / Refer to Catalogs: 0611CT1001 www.se.com/us PowerPact L-Frame Molded Case Circuit Breakers (600 A) A flexible, high performance offer certified to global standards.
PowerPact L-Frame Electronic-Trip Circuit Breakers PowerPact™ Molded Case Circuit Breakers Class 611 / Refer to Catalogs: 0611CT1001 www.se.com/us Table 7.66: L-Frame 600 A 100% Rated UL Current-Limiting [34] Circuit Breakers with Lugs and Factory-Sealed Electronic Trip Units Suitable for Reverse Connection [35][36] Electronic Trip Unit Type Function 600 Vac, 50/60 Hz, 3P Micrologic Standard Trip Unit LI 3.3 [37] Micrologic Standard LSI 3.
PowerPact™ Molded Case Circuit Breakers M-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 www.se.com/us PowerPact M-Frame Molded Case Circuit Breakers (800 A) PowerPact M-frame circuit breakers use an electronic trip system with the simplicity of a thermal magnetic breaker.
P-Frame Circuit Breakers PowerPact™ Molded Case Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 www.se.
PowerPact™ Molded Case Circuit Breakers R-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 www.se.com/us PowerPact R-Frame Molded Case Circuit Breakers (3000 A) • • • • • • Micrologic electronic trip protection from 600–3000A up to 600 Vac 2-, 3- and 4-pole construction UL listed interrupting ratings from 35 to 100 kA at 480Vac Built-in Modbus protocol Standard (80%) and 100% rating UL, CSA, NOM, CCC and IEC certified and CE marked for global acceptance Table 7.
R-Frame Circuit Breakers PowerPact™ Molded Case Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 www.se.com/us Table 7.78 R-Frame 3000 A (600 Vac, 50/60 Hz) 3P Circuit Breaker with Electronic Trip Unit (cont'd.) Type Electronic Trip Unit [45] Function LSIG Trip Unit 6.0H Sensor Rating Cat. No.
Mission Critical Circuit Breakers Selective Coordination Class 500, 600 www.se.com/us PowerPact Mission Critical Circuit Breakers Delivering high levels of selective coordination in a flexible design that can be easily configured for a variety of applications.
UL Listed 500 Vdc Circuit Breakers 500 Vdc Circuit Breakers Class 500, 600 www.se.com/us PowerPact 500 Vdc Circuit Breakers Designed for use on ungrounded dc systems having a maximum short-circuit voltage of 500 Vdc or a maximum floating (unloaded) voltage of 600 Vdc. Suitable for use only with UPS (ungrounded uninterruptable power supplies systems). CAUTION/PRECAUCION/ ATTENTION Connect only as shown/Conectar solo asi/ Brancher seulement comme suit: + 600 V MAX. + Load/Carga/ Charge 600 VMAX.
Automatic Switches PowerPact Automatic Switches Class 600 / Refer to Catalog 0612CT0101 www.se.com/us PowerPact Automatic Switches J-Frame Switch L-Frame Switch Automatic molded case switches open instantaneously at a factory preset magnetic trip point. Calibrated to protect only the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no overload or low level fault protection.
Instantaneous Trip Circuit Breakers Motor Circuit Protectors Class 600 / Refer to Catalog 0612CT0101 www.se.com/us Instantaneous Trip Circuit Breakers for Motor Protection Applications Adjustable instantaneous-trip circuit breakers are intended for use in combination with motor starters with overload relays for the protection of motor circuits from short circuits. Other specific applications include rectifiers and resistance welders.
Motor Circuit Protectors PowerPact™ Electronic Motor Circuit Protectors Class 611 / Refer to Catalog 0611CT1001 www.se.com/us PowerPact Motor Circuit Protection (AC Only) PowerPact electronic Motor Circuit Protectors (MCP) are magnetic-only instantaneoustrip circuit breakers. Designed to offer short circuit protection, they are National Electrical Code (NEC) compliant when installed as part of a combination controller having motor overload protection.
H-Frame and J-Frame MCP Selector Motor Circuit Protectors Class 611 / Refer to Catalog 0611CT1001 www.se.com/us PowerPact Motor Circuit Protectors Table 7.95: Application of PowerPact™ H-Frame and J-Frame Electronic Motor Circuit Protectors (MCP) © 2019 Schneider Electric All Rights Reserved 9/13/2019 0.9 A 1.1 A 1.3 A 1.7 A 2.1 A 2.2 A 2.4 A 2.5 A 2.7 A 3A 3.2 A 3.4 A 3.7 A 3.9 A 4.2 A 4.8 A 4.8 A 6A 6.1 A 6.8 A 6.9 A 7.6 A 7.8 A 9A 9.6 A 11 A 14 A 15.2 A 17 A 17.5 A 21 A 22 A 25.
Motor Circuit Protectors Motor Circuit Protectors and Motor Protector Circuit Breakers Class 580, 585, 680, 685 www.se.com/us PowerPact Motor Protector Circuit Breakers—Two Device Solutions Accessories see page 7-49 and Supplemental Digest Section 3 Optional Lugs see page 7-54 and Supplemental Digest Section 3 Dimensions see page 7-81 Enclosures see page 7-82 Micrologic 2.2M and 2.3M trip units provide built-in thermal and magnetic protections.
Electrical Accessories PowerPact™ Circuit Breaker Accessories Class 612 / Refer to Catalog 0612CT0101 www.se.com/us PowerPact Accessories Table 7.98: Electrical Accessories Accessory Description Auxiliary and Alarm Switches (OF, SD, SDE) Standard Min Load = 10mA with 24V B-Frame Provides circuit breaker contact status. Note: The location of the accessory in the circuit breaker determines its function.
PowerPact™ Circuit Breaker Accessories Motor Operators and Rotary Handles Class 612 / Refer to Catalog 0612CT0101 www.se.
Motor Operators and Rotary Handles PowerPact™ Circuit Breaker Accessories Class 612 / Refer to Catalog 0612CT0101 www.se.
Locks, Installation Accessories, and Rear Connections PowerPact™ Circuit Breaker Accessories Class 612 / Refer to Catalog 0612CT0101 www.se.com/us Locks, Installation Accessories, and Rear Connectors Removable Padlock Attachment Fixed Padlock Attachment Interlocking with Toggle Control Table 7.
Locks, Installation Accessories, and Rear Connections PowerPact™ Circuit Breaker Accessories Class 612 / Refer to Catalog 0612CT0101 www.se.com/us Table 7.101: Installation Accessories for M-, P-, and R-Frame Circuit Breakers Description Accessory Cover Door Escutcheon Door Escutcheon Terminal Covers Terminal Covers Replacement Handle Field-Installable Cat. No.
Mechanical Lugs PowerPact™ Circuit Breaker Accessories Class 612 / Refer to Catalog 0612CT0101 www.se.com/us Mechanical Lugs Table 7.
Compression Lugs and Power Distribution Connectors (PDC) www.se.com/us PowerPact™ Circuit Breaker Accessories Class 612 / Refer to Catalog 0612CT0101 Compression Lugs A = Crimp lugs or PDC connectors extension past end of circuit breaker “A” See Table Molded Case w/Mechanical Lugs P-Frame Compression Lug Kit R-Frame Compression Lug Kit J-Frame Compression Lug “A” See Table Table 7.107: Compression Lug Kits for PowerPact™ Circuit Breakers System Range Mounting Type Dimension A (in) Max.
PowerPact™ Circuit Breaker Accessories Compression Lugs and Power Distribution Connectors (PDC) Class 612 / Refer to Catalog 0612CT0101 www.se.com/us Power Distribution Connectors Power distribution connectors (PDCs) can be used for multiple load wire connections on one circuit breaker in place of standard distribution block to save space and time. The connectors are attached to circuit breaker terminals equipped with separately provided terminal nut connectors.
Terminal Nuts, Terminal Pads, Terminal Shields and Accessories PowerPact™ Circuit Breaker Accessories Class 612 / Refer to Catalog 0612CT0101 www.se.com/us Terminal Accessories Table 7.
Plug-In and Drawout Mountings PowerPact™ Circuit Breaker Accessories Class 611, 612 / Refer to Catalog 0611CT1001, 0612CT0101 www.se.com/us Mountings Table 7.
PowerPact H-, J-, and L-Frame Trip Units Micrologic™ Electronic Trip Units Class 611 / Refer to Catalog 0611CT1001 www.se.com/us Micrologic Trip Units [1] Micrologic Standard 3.2/3.3 Trip Units PowerPact H-, J-, and L-Frame Micrologic Trip Units Micrologic Standard Trip Unit Micrologic Ammeter and Energy Trip Unit PowerPact™ H-, J-, and L-frame molded case circuit breakers may be specified with any of the following Micrologic Electronic Trip Units.
Micrologic™ Electronic Trip Units PowerPact P- and R-Frame Trip Units Class 612 / Refer to Catalog 0612CT0101 www.se.com/us PowerPact P- and R-Frame Micrologic Trip Units Micrologic (Standard) 3.0 and 5.0 Trip Units PowerPact P- and R-Frame Micrologic Trip Units PowerPact™ P- and R-frame molded case circuit breakers may be specified with any of the following Micrologic Electronic Trip Units.
PowerPact P- and R-Frame Trip Units Micrologic™ Electronic Trip Units Class 612 / Refer to Catalog 0612CT0101 www.se.com/us Table 7.121: PowerPact P- and R-Frame Micrologic Trip Unit and Options Model Protection 2.0 (IEC only) 3.0 (UL/ANSI only) 5.0 2.0A (IEC only) 3.0A (UL/ANSI only) 5.0A 6.0A 5.0P 6.0P 5.0H 6.0H LSO LI LSI LSO LI LSI LSIG LSI LSIG LSI LSIG Field-Installable Cat. No.
Micrologic™ Electronic Trip Units Micrologic™ Trip Unit Accessories Class 612, 612 / Refer to Catalogs 0611CT1001 and 0612CT0101 www.se.com/us Trip Unit Accessories Sensor Plug Trip Unit Seal For Enerlin’X accessory information, see Enerlin’X Digital Solutions, page 7-75 Table 7.125: Rating Plugs Rating Plug [7] A B C D E F G H Table 7.128: Trip Unit Accessories Factory Installed Cat. Suffix A (standard) B C D E F G H Field-Installable Cat. No.
Micrologic™ Trip Unit Accessories Micrologic™ Electronic Trip Units Class 612, 612 / Refer to Catalogs 0611CT1001 and 0612CT0101 www.se.com/us Table 7.130: Electronic Trip Unit Accessories, Wire Harness [14] and ULP Cords for H-, J-, and L-Frame Circuit Breakers [15] L = 1.3 m (4.27 ft) L = 3 m (9.84 ft) L = 1.3 m (4.27 ft) L = 3 m (9.84 ft) Factory-Installed Cat. No. Suffix EA EB EG [17] EH [17] L = 1.3 m (4.27 ft) L = 3 m (9.
Masterpact™ Power Circuit Breakers Masterpact™ MTZ Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Masterpact MTZ Circuit Breakers Masterpact MTZ continues the performance and reliability of the Masterpact line. Masterpact MTZ circuit breakers bring innovation and upgradability throughout the entire lifecycle, for improved power uptime, business performance, and cost control.
Masterpact™ MTZ Circuit Breakers Masterpact™ Power Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Micrologic X Control Unit for Masterpact MTZ Circuit Breakers Menus Warning MICROLOGIC MICROLOGIC MICROLOGIC Home Home Micrologic X measures electrical parameters of a power system: currents, voltages, frequency, power, energy, power factor, current and power demand. Min/Max and average values are calculated for most of the parameters.
Masterpact™ Power Circuit Breakers Masterpact™ MTZ Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Micrologic X Sensor Plugs Table 7.
Masterpact™ MTZ Circuit Breakers Masterpact™ Power Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Masterpact MTZ Accessories Table 7.
Masterpact™ Power Circuit Breakers Masterpact™ MTZ Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Communication Accessories Table 7.
Masterpact™ MTZ Circuit Breakers Masterpact™ Power Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Auxiliary, Alarm Contacts and Power Supply Catalog Numbers Table 7.
Masterpact™ Power Circuit Breakers Masterpact™ MTZ Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Neutral Sensors Catalog Numbers Table 7.144: Neutral Sensor Parts Catalog Number Neutral Sensor Wiring Harness for MTZ1/2 Neutral Sensor Wiring Harness for MTZ3 External sensor (SGR)[9] MDGF/SGR (Source Ground Return) Sensor plug MDGF summing module for MTZ2/3 LV848907SP LV848906SP LV833579SP LV848891SP Table 7.
Masterpact™ MTZ Circuit Breakers Masterpact™ Power Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Spring Charging Motor and Remote Accessories Catalog Numbers Table 7.
Masterpact™ Power Circuit Breakers Masterpact™ MTZ Circuit Breakers Class 0614 / Refer to Catalog 0614CT1701 www.se.com/us Miscellaneous Accessory Catalog Numbers Table 7.149: Escutcheon Description Fixed Catalog Number Drawout Escutcheon Masterpact MTZ1 Terminal Cover (CB) Masterpact MTZ2/3 Grounding Kit KTM Masterpact MTZ2/3 Transparent Cover for Escutcheon.
Masterpact™ NT/NW Circuit Breakers Masterpact™ Power Circuit Breakers Class 613 / Refer to Catalog 0613CT0001 www.se.com/us Masterpact NT and NW Circuit Breakers Masterpact NT The Masterpact NT and NW universal power circuit breakers offer a family of circuit protection products meeting the most common world standards, ANSI, UL and IEC. The basic design platform for each is common. The final result is UL, ANSI and IEC circuit breakers with the same basic external dimensions, features and accessories.
Masterpact™ Power Circuit Breakers Masterpact™ NT/NW Circuit Breakers Class 613 / Refer to Catalog 0613CT0001 www.se.com/us Table 7.
Enerlin’X System Enerlin’X Digital Solutions Class 0614 / Refer to Catalog 0614CT1802 www.se.com/us Enerlin’X System for Micrologic Trip Units Enerlin’X Systems enable network connectivity for Masterpact and PowerPact circuit breakers to provide remote monitoring, control & alarming features which is central to the Smart Systems Architecture with Square D low voltage distribution equipment.
Enerlin’X Digital Solutions Enerlin’X System Class 0614 / Refer to Catalog 0614CT1802 www.se.com/us Enerlin’X System Accessories Accessories for Enerlin’X Modules Table 7.
Multi-Product Architecture Examples Enerlin’X Digital Solutions Class 0614 / Refer to Catalog 0614CT1802 www.se.com/us Hybrid Communication—Ethernet and Modbus NOTE: Refer the Smart System Data Acquisition user guide (https://www.schneiderelectric.us/en/download/document/0614DB1801/) to aid in component selection for Smart Systems. 1 3 EBX510 Com’X Energy Server RJ45 Ethernet cable Com’X 210 Energy Data Logger: EBX210 Com’X 510 Energy Server: EBX510 VDIP184546010 (L = 1 m [3.28 ft.
Multi-Product Architecture Examples Enerlin’X Digital Solutions Class 0614 / Refer to Catalog 0614CT1802 www.se.com/us Communications—Direct Ethernet NOTE: Refer the Smart System Data Acquisition user guide (https://www.schneiderelectric.us/en/download/document/0614DB1801/) to aid in component selection for Smart Systems.
Add-On Ground-Fault and Earth-Leakage Modules Ground-Fault Protection Class 931, 940, 960 www.se.com/us Micrologic™ Add-on Ground-Fault Module (GFM) The Micrologic Ground-Fault Module (GFM) is a UL Listed/CSA Certified circuit breaker accessory which protects equipment from damage caused by ground faults. It is an addon module which, when connected to a PowerPact H- or J-frame thermal-magnetic circuit breaker only, provides ground-fault sensing and ground-fault relay functions.
Dimensions and Shipping Weights Miniature and Molded Case Circuit Breakers Class 931, 940, 960 www.se.com/us Miniature and Molded Case Circuit Breaker Dimensions Table 7.160: QO™, QOU, Multi 9™ Circuit Breakers Figure 1 A G Figure 2 A G QO, QOB D C Figure 3 A G Circuit Breaker Cat. No.
Molded Case Circuit Breakers Dimensions and Shipping Weights Class 931, 940, 960 www.se.com/us Molded Case Circuit Breaker Dimensions Table 7.163: PowerPact B-, H-, J-, and L-Frame Circuit Breakers Figure 25 B Circuit Breaker Frame Figure 26 B G No. of Poles 1 2 3 4 2 [8] 3 3 3 E B-Frame F A F A D E H-Frame C J-Frame L-Frame Figure 27 Circuit Breaker Cat. No. Prefix ED, EG, EJ ED, EG, EJ ED, EG, EJ GJ D F A A 6.79 6.22 6.22 6.22 6.40 6.40 7.52 13.38 B 1.06 2.12 3.19 4.25 2.74 4.12 4.
Enclosures Circuit Breaker Enclosures Class 610 www.se.com/us PowerPact Circuit Breaker Enclosures • • • • The enclosures for the family of PowerPact circuit breakers B- through Q-frame are cULus listed unless otherwise noted. The enclosures are suitable for service entrance equipment when neutral assembly is installed. The short circuit current rating of the enclosed circuit breakers is equal to the rating of the circuit breaker installed unless otherwise noted.
Enclosures Circuit Breaker Enclosures Class 610 www.se.com/us PowerPact L-Frame Circuit Breaker and Molded Case Switch Enclosures All enclosures accept 80% rated circuit breakers. The enclosures will also accept 100% rated circuit breakers to 400 amps. The enclosures have a blank top end wall and require field-cut openings. For details and hub catalog numbers see page 3–10. Table 7.169: PowerPact L-Frame Circuit Breaker Enclosures Circuit Breaker Cat. No. Rating Cat. No.
Enclosures Circuit Breaker Enclosures Class 610 www.se.com/us LA/LH/Q4 Circuit Breaker Enclosures LA/LH/Q4 Thermal-Magnetic Circuit Breaker Enclosures The enclosures for the LA/LH/Q4 thermal-magnetic circuit breakers are UL listed and CSA certified. The enclosures are suitable for service entrance equipment when neutral assembly is installed. The short circuit ratings of these enclosed circuit breakers are equal to the interrupter rating, at the supply voltage marked on the circuit breaker installed.
Enclosure Accessories and Dimensions Circuit Breaker Enclosures Class 610 www.se.com/us Enclosure Accessories Table 7.
Enclosure Accessories and Dimensions Circuit Breaker Enclosures Class 610 www.se.com/us Enclosure Dimensions H H W W D WB enclosure uses 2 circuit breakers NEMA Type 1 H H H W D WB enclosure uses 2 circuit breakers NEMA Type 3R (Uses side hinge cover) W D NEMA Type 7, Type 9 W D NEMA Type 4, 4X, 5, 12, 12K Table 7.177: Dimensions Cat. No.