User manual

14
730.927 | 09.10
Load cannot be
operated
+
info LED flashes
red
+
red battery LED
flashes
Load output is switched
off due to too low battery
voltage
The load output automati-
cally switched on again as
soon as the battery voltage
lies within the permissible
range
Pre-charge the battery
Equip loads directly con-
nected to the battery with
deep discharge protection
Check the battery and
replace if necessary
Load cannot be
operated
+
info LED flashes
red
+
2. green LED
flashes
Load output is switched
off due to excessive battery
voltage
The load output automati-
cally switched on again as
soon as the battery voltage
lies within the permissible
range
External charging source is
not voltage-limited
Check the external charging
source
If necessary, switch off
external charging sources
Load cannot be
operated
+
info LED illumi-
nates green
Defective load or installa-
tion error
Connect load correctly
Replace load
Battery is not
charged
Solar module not connected Connect the solar module
Solar module connected
with incorrect polarity
Connect the solar module
with the correct polarity
Short circuit at solar module
input
Correct the cause of the
short circuit
Incorrect solar module
voltage
Use a solar module of the
specified voltage
Device overheated Make sure the device is well
ventilated
Solar module defective Replace the solar module
Battery display
jumps quickly
Large pulse current Tune the current consump-
tion to match the battery
capacity
Battery is defective Replace the battery