User manual

Fig. 8: External conductor voltages in 2- and 3-phase grids with 100 V ... 127 V
4.4 Preparing the DC connections
DANGER!
Risk of death by electrocution!
Observe the warning notes in
Ä 4.1, p. 102
.
coolcept: Opposing Multi-Contact connectors must be used for the DC cable to suit the
Multi-
Contact MC4
plug connectors (opposing connectors optionally available).
coolcept-x: Use the SunClix plug connectors provided to ensure that the specified degree of
protection is maintained.
ATTENTION!
Danger of damage to the inverter and the modules. Connect the opposing connectors for the DC
connections to the DC cable, observing the correct polarity.
1. Attach the connector plug counterparts to the DC cable according to the manufacturer's
instructions; see Appendix.
2. If legally prescribed (e.g. France), plug in the optionally available safety sleeves, according to
the manufacturer's instructions (
Fig. 9).
Fig. 9: Safety sleeve unmounted (left) and mounted (right)
4.5 Preparing the data connection cable
If a data connection is required, use a standard RJ45 cable (patch cable, Cat5) or construct an
alternative data connection cable (see
Ä 3.6, p. 96
).
GB
747.431 | Z08 | 2014-01-31
107