User manual

Event message Description Type
Intern.
info
u
Contact your installer if this message occurs frequently.
Intern.
warning
u
Contact your installer if this message occurs frequently.
Intern.
error
u
Contact your installer if this message occurs frequently.
Self test
failed
An error occurred during the self test and the self test was cancelled.
u
Contact your installer when
n the self test is cancelled due to an error several times at different
times of the day and
n it is certain the the grid voltage and frequency were within the limit
values defined by the country setting; see
Ä 9.3, p. 141
.
Faulty coun-
try
settings
An inconsistency exists between the selected country settings and those
stored in memory.
u
Contact your installer.
BCONV over-
temperature
The maximum permissible boost converter temperature has been
exceeded. The inverter feeds no power into the grid until the maximum
permissible temperature is no longer exceeded.
1. Check that the installation conditions are satisfied.
2. Contact your installer if this message occurs frequently.
Boost con-
verter de-
fective
The boost converter is defective, the inverter is not feeding into the grid
or is feeding at reduced power.
u
Contact your installer.
Boost con-
verter not
detected
u
Contact your installer.