User manual

Note
Due to legal requirements, the values in the table above may change at short notice. For current
values, see
http://www.stecasolar.com.
1)
Country code and name as shown on the display.
2)
Disconnection values are upper and lower deviations from the peak values of the rated voltage
(in %) and the associated switch-off time (in s).
3)
Disconnection values are upper and lower deviations from the average values of the rated
voltage (in %) and the associated switch-off time (in s).
4)
Disconnection values are upper and lower deviations from the rated frequency (in Hz) and the
associated switch-off time (in s).
5)
StecaGrid 3600 and 4200 only:
Maximum output power Belgium 1 / Belgium 2: 3330 W
Maximum output power Belgium 1 unl. / Belgium 2 unl.: 3600 W
6)
The rated voltage is 240 V (instead of 230 V).
7)
All units except the StecaGrid 1800: maximum output power 2000 W
8)
The rated voltage is 220 V (instead of 230 V).
9)
————————————————————————————————————————
ATTENTION
Danger of yield losses. Activation of the
Droop Mode
is not permitted in systems connected to
the public electricity grid.
————————————————————————————————————————
Activation of the
Droop Mode
is recommended when the inverter is operated in conjunction
with a stand-alone inverter in a system that is not connected to the public electricity grid.
Droop Mode
: 50 Hz;
Droop Mode 60 Hz
: 60 Hz.
Italy 8
: Systems smaller than 3 kW maximum output power;
Italy 9
: Systems greater than 3 kW
maximum output power
Notice
The requirements for the country-specific grid parameters may change at short notice. Contact the
Steca Customer Service if the parameters specified in the table below no longer correspond to the
legally prescribed requirements in your country. See Ä Contact, p. 145.
Information on setting the country are provided in Ä 4.7, p. 108 et seqq.
GB
747.431 | Z08 | 2014-01-31
142