User manual
Information
The menu item Information contains the following submenu
items.
n Contact info
n System info (see Fig. left):
– Product designation
– Serial number of the inverter
– Information on the software and hardware versions of the
inverter (see example ① in Fig. left)
– Inverter address
– Version of the operating instructions for the inverter
n Country setting: Country that is currently set and country-
specific grid parameters; see also
Ä 9.3, p. 141
.
n React. pwr. char. curve: Reactive power characteristic
curve graph (only when prescribed for currently set country)
n Network: Network parameters, partially configurable under
Settings ▶ Network
– DHCP status: DHCP on/off
– Link status: Network connection state
– IP address: IP address of the inverter
– Subnet mask: Subnet mask of the inverter
– Gateway: IP address of the network gateway
– DNS-Adresse: IP address of the DNS server
– MAC address: Hardware address of the inverter
n Result of the last self test (only when the configured country is
Italy
)
3.3.3 Settings
Numerical settings
①
Designation of the numerical setting
②
Value to be set; the selected value to be set is highlighted in
black.
When performing numerical settings of remuneration and dates,
the following applies:
Remuneration
n Possible currencies: £ (Pounds), € (Euros), kr (Krones),
none
.
n The maximum value that can be set for remuneration is limited
for technical reasons. The remuneration must be set using dif-
ferent units as required. Example: Dollars instead of Cents (set
a currency of
none
).
Date
When setting the month/year, a check is performed to ensure that
the selected day is valid. If not, then the day is automatically cor-
rected.
Example: 31.02.2011 is corrected to 28.02.2011.
GB
747.431 | Z08 | 2014-01-31
91