User manual

Power limiting
The inverter output power can be manually limited to a minimum of
500 W. When the power is manually limited, the
Derating
symbol is
shown in the status display and the
‘Derating’
/
‘Cause: User
default’
measurement is displayed.
Fixed voltage
The device can regulate the input voltage to a manually adjustable
value. This switches off the automatic setting of the MPP (MPP
tracking). The input voltage can be adjusted over a range between
the maximum and minimum input voltage.
Example of application: fuel cell
ATTENTION!
Before setting a fixed input voltage, make sure that the generator is suitable for this. Otherwise,
this may result in yield losses or damage to the system.
Delete country setting
After the country setting has been deleted the device restarts anew
and displays the guided initial commissioning menu.
Factory setting
Resetting the device to the factory setting deletes the following
data:
n Yield data
n Event messages
n Date and time
n Country setting
n Display language
n Network settings
After the factory setting has been deleted, the device starts anew
and displays the guided initial commissioning menu.