Data Sheet

14
The Steca Solsum-Line continues the huge success of one of the most
used SHS controllers. With a power range of up to 10 A at automatically
recognized 12 V or 24 V it fits to a system sizes of maximum 240 W.
Full circuit board protection with LED display for simple recognition of bat-
tery status. Various connections make it possible to connect easily to solar
panels, battery and load. The Steca Solsum works on PWM as a low loss
series controller.
Product features
Serial topology with MOSFETs
Automatic detection of voltage
Voltage regulation
PWM control
Multistage charging technology
Current compensated load disconnection
Automatic load reconnection
Temperature compensation
Negative earthing of one or positive earthing of several terminals
possible
Monthly equalisation charge
Electronic protection functions
Overcharge protection
Deep discharge protection
Reverse polarity protection of module (≤ 36 V), load and battery
Automatic electronic fuse
Short circuit protection of load and module
Overvoltage protection at module input
Open circuit protection without battery
Reverse current protection at night
Overtemperature and overload protection
Load disconnection on battery overvoltage
Displays
Multifunction LED display
Multi-coloured LED
4 LEDs show operating states
~ for operation, state of charge, fault messages
Options
Evening or night light function pre-set in the factory or adjustable via
Steca PA RC 100
Parameterisation of function values via Steca PA RC 100
Certificates
Compliant with European Standards (CE)
RoHS compliant
Made in EU
Manufactured according to ISO 9001 and ISO 14001
Steca accessories
Remote control Steca PA RC100
STECA SOLSUM
0606 | 0808 | 1010
6 A...10 A
0606 0808 1010
Characterisation of the operating performance
System voltage 12 V (24 V)
Own consumption < 4 mA
DC input
Open circuit voltage solar module
(at minimum operating temperature)
< 47 V
Module current 6 A 8 A 10 A
DC output
Load current** 6 A 8 A 10 A
Reconnection voltage (LVR)* 12.4 V … 12.7 V
(24.8 V … 25.4 V)
Deep discharge protection (LVD)* 11.2 V … 11.6 V
(22.4 V … 23.2 V)
Battery
End of charge voltage* 13.9 V (27.8 V)
Boost charge voltage* 14.4 V (28.8 V)
Set battery type* gel
Operating conditions
Ambient temperature -25 °C … +50 °C
Fitting and construction
Terminal (fine / single wire) 4 mm
2
/ 6 mm
2
- AWG 12 / 9
Degree of protection IP 31
Dimensions (X x Y x Z) 145 x 100 x 30 mm
Weight approx. 150 g
Technical data at 25 °C / 77 °F
* adjustable via Steca PA RC100
** Inverters must not be connected to the load output.
STECA
Quality
NIGHT-
LIGHT
145
30
4x
4
135
89
5
5
100
INFO
BATTERY

Summary of content (1 pages)