Instructions

– 12 –– 12 –
spectively of light-level setting. The programme
is automatically activated after this time elapses.
The red LED stays ON all the time in test mode.
Setting the chosen operating mode by
programme selector switch
P0: OFF (factory setting).
Loads (LED panel and sensor) are deactivated.
P1: Sensor mode.
Light only switches ON after receiving a signal
from the motion detector.
P2: Sensor mode with basic light level.
Light switches ON after receiving a signal from
the motion detector.
Light permanently ON in the morning and
evening hours at reduced basic light level.
Stay-ON time and brightness
Stay-ON time is determined when the light is
used for the first time.
During the first night, basic lighting is switched
OFF in the morning in programme 2.
Stay-ON time and brightness can be automati-
cally matched to ambient conditions, e.g. stay-
ON time is longer in summer than it is in winter.
Basic lighting level provides night-time illumina-
tion at approx. 3% light output. Light is switched
to maximum output when movement is identified
in the detection zone. The light then returns to
basic lighting level (approx. 3%).
The period basic lighting is provided for is
matched to ambient conditions. Using basic
lighting reduces light availability. If it is not need-
ed, it is recommended to switch it OFF (P1) to
ensure lighting availability in less sunny periods.
Charging the battery manually
The red LED in the motion detector flashes if
battery capacity is too low (e.g. in poor weather).
The battery can be recharged with a standard
micro USB charging adapter (not included). Battery
recharging can take up to 6 hours.
Risk of damage to property from penetrating
moisture
When open, the micro USB charging socket (E) is
not protected from the ingress of water.
Only recharge batteries in a dry room.
Connect micro USB charging adapter.
Red LED flashes: charging in progress
The LED may take up to 10 minutes to start
flashing if the battery has run down to very
low level.
Red LED shows: battery is fully charged.
Remove micro USB charging adapter.
Red LED goes out.
Risk of damage to property when light is not in use
If the light is not used for a prolonged period
(e.g. in storage), the battery may suffer irreparable
damage from exhaustive discharge.
Set programme selector switch to P0.
The battery must be on full charge before taking
the light out of service.
Regularly charge the battery while the light is
not in use.
7. Malfunctions
Red LED flashing in motion detector
Battery capacity too low.
• Charge battery with micro USB charging
adapter (not included).
Light does not switch ON
Battery capacity too low.
Charge battery with micro USB charging
adapter (not included).
Open or short circuit.
Check connections.
Programme selector switch set to P0.
Set programme selector switch to P1 or P2.
Detection zone not correctly adjusted.
Check detection zone.
Light does not switch OFF
Continued movement within the detection zone.
Check detection zone.
Light switches ON when it should not
Uncontrolled movement in the detection zone:
Wind is moving trees and bushes.
Cars in the street being detected.
Sudden temperature changes due to weather
(wind, rain, snow) or air expelled from fans,
open windows.
Check detection zone.
Light is swaying (moving) due to gusts of wind or
heavy rain.
Mount light on a firm surface.
Battery not charging
Solar panel dirty.
Clean solar panel with a soft cloth and mild
detergent.
Solar panel not installed in the best place.
Check site of installation (as much direct
sunlight as possible).