6.1. Dry er
The dry er ope ra tes with de hu mi di fied air, i.e. the air is not only hea ted but also de hu mi di fied be fo -
re flo wing into the dry ing hop per. This prin ci ple al lows plas tic gra nu les to be dried to a re si du al
moi stu re con tent as low as 0.002 % (PET gra nu la te).
The dry er ope ra tes con ti nu ous ly, i.e. de hu mi di fied and, if ne ces sa ry, hea ted air is pro du ced con -
ti nu ous ly.
F
The dry er is de sig ned for con ti nu ous ope ra ti on.
The dryer op er ates with 4 dry ing cells; two of these cells are al ways in the dry ing cy cle while the
other are be ing re gen er ated (max. 60 min.).
If a mal func tion oc curs in the dry ing cy cle dur ing the pro gram run, re gen er a tion is not in ter rupted,
but con tin ues un til the pro gram end has been reached. This guar an tees that 2 re gen er ated dry ing
cells are al ways avail able.
The air in si de the switch ca bi net is coo led by a coo ling ap pli an ce for the pro tec ti on of tem pe ra tu -
re-sen si ti ve com po nents (if pre sent, op tio nal).
With the di gi tal ti mer the dry er can be swit ched on and off at set ti mes.
Dew point de pen dent re ge ne ra ti on switch (op tio nal)
The dew point tem pe ra tu re is mo ni to red con ti nu ous ly. The val ve sys tem swit ches to the freshly
re ge ne ra ted dry ing cells only af ter the se lec ted dew point tem pe ra tu re has been rea ched. The hu -
mid dry ing cells are then re ge ne ra ted. Af ter the coo ling time the dry ing cells are rea dy for ope ra ti -
on again. The val ve sys tem swit ches to the freshly re ge ne ra ted dry ing cells only af ter the moi stu -
re con tent of the dry ing cells which are in the dry ing cy cle have rea ched the set point va lue.