Instruction Manual

- 7 -
SIDE VIEW
6.2 in.(158mm)
MODELS WITH HORN (STI-1100 Series)
COVER
5.5 in.(140mm)
8.5 in.(216mm)
3.2 in.(81mm)
2 in.(51mm)
ALL MODELS END VIEW
COVER
3.2 in.(81mm)
2 in.(51mm)
5.5 in.(140mm)
5 in.(127mm)
3 in.(76mm)
SPACER
SPACER
SIDE VIEW
7.0 in.(178mm)
MODELS WITHOUT HORN (STI-1200 AND STI-3150 Series)
COVER
6.5 in.(165mm)
8.5 in.(216mm)
3.2 in.(81mm)
2 in.(51mm)
SPACER
3 in.(76mm)
DEPTH CHART FOR STI STOPPER II
4 in.(102mm)
5 in.(127mm)
5.5 in.(140mm)
STI-3100 SPACER
ADDS 2" DEPTH(51mm)
FOR SURFACE MOUNTED
PULL STATIONS
.75 in.(19mm)
1.625 in.(41mm)
2.375 in.(60mm)
2.75 in.(70mm)
3.2 in.(81mm)
5.5 in.(140mm)
HORN HOUSING
3 in.(76mm)
ALL MODELS END VIEW
4 in.(102mm)
5 in.(127mm)
5.5 in.(140mm)
STI-3100 SPACER
ADDS 2" DEPTH(51mm)
5.5 in.(140mm)
E
.75 in.
(19mm)
1.625 in.
(41mm)
2.375 in.
(60mm)
2.75 in.
(70mm)
3.2 in.
(81mm)
A
B
C
D
E
D
C
B
A
PULL DOWN
STI-1280 BACKPLATE
INSERT
(2) PROVIDED
STI-3003 GASKET (1/2 in. CONDUIT)
STI-3004 GASKET (3/4 in. CONDUIT
AND STI-3104 SPACER)
STI-3002 WEATHER GASKET
FOR WEATHER OPTION
(USE TWO WITH SPACER)
STI-3100 CONDUIT SPACER - STANDARD SPACER
INCLUDED WITH SURFACE MOUNT UNITS
STI-3104 CONDUIT SPACER ACCOMMODATES
3/4 in. CONDUIT FOR WEATHER STOPPER
SUB-315 GRILL
SUB-316
LOUVER
*NOTE: STI SUGGESTS USING THE
STI-1280 BACKPLATE FOR WEATHER UNITS
OR WHEN MOUNTED ON AN UNEVEN SURFACE.
WALL
OPTIONAL STI-1103
RELAY BOARD
RED +9, 12, OR 24 VOLTS
BLACK -9, 12, OR 24 VOLTS
GREEN NORMALLY OPEN
BLUE COMMON
WHITE NORMALLY CLOSED
3/32 in. ALLEN WRENCH
(NOT PROVIDED)
SWITCH LOCKING SCREW
5 INCHES OF CABLE IS
PROVIDED FOR SERVICE LOOP.
MAKE SURE THIS LOOP AND
ALL OTHER CABLES DO NOT
INTERFERE WITH STATION
OPERATION.
TO LOCK POWER SWITCH IN
THE "OFF" OR "ON" POSITION
TIGHTEN LOCKING SCREW FULLY
UNTIL SCREW MAKES CONTACT
WITH SWITCH PAD AS SHOWN.
OFF
OPTIONAL RELAY CONTACT SETTINGS
STI MODELS 1100RC, 1130RC, 1150RC AND 1155RC
( NOT USED WITH 9VDC BATTERY JUMPER)
*
*
*
ADDED
SILICONE
EXISTING
PULL STATION
SCREW WITHOUT SPACER
FLUSH MOUNT
WITH OPTIONS
SURFACE MOUNT
WITH OPTIONS
ANCHOR
(4) PROVIDED
EXISTING PULL
STATION
INSERT PLASTIC KNOCK-OUT (2) PROVIDED
INTO SPACER NOTCH IF CONDUIT IS NOT NEEDED
STI-3003 GASKET (USE WITH 1/2 in. CONDUIT)
STI-3004 GASKET (USE WITH 3/4 in. CONDUIT
AND STI-3104 SPACER)
STI-3100 CONDUIT SPACER SHOWN
WITH SUB-316 AND SUB-315
FOR ADDITIONAL VENTILATION
ORDER SUB-316 LOUVER KIT
OR SUB-315 GRILL
SCREW WITH SPACER
BACKPLATE
NOTE: WHEN DRILLING HOLE IN
BACKPLATE NEMA 3R INTEGRITY
IS COMPROMISED
ADHESIVE SIDE
STI-3002 WEATHER GASKETS
INSTALL THICK END OF GASKET
TOWARDS TOP OF ASSEMBLY
STI-1280
BACKPLATE
VIEW OF RELAY CONTACT
15 - 24 VDC
9 - 12 VDC
GROUND
NORMALL OPEN
NORMALLY CLOSED
COMMON
USE ONLY
9 VOLT BATTERY
JUMPER USED ON STANDARD 9
VOLT INTERNALLY
POWERED MODELS
JUMPER INSTALLED ON "RC" MODELS
FOR EXTERNALLY SUPPLIED 12VDC OR
24VDC POWER
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD
THIS JUMPER IS INCLUDED WITH "RC"
MODELS FOR USE WHEN INTERNAL
9VDC BATTERY POWER IS REQUIRED.
(BATTERY NOT INCLUDED)
SMALL CONNECTOR ON JUMPER FITS
INTO PLUG ON RELAY BOARD
USING THIS JUMPER REQUIRES
VOLTAGE SELECTOR SET TO 9V
STI-1103 RELAY
BOARD IS USED ON
"RC" MODELS
VOLTAGE SELECTOR
9V 24V
FACTORY VOLTAGE SETTINGS:
BATTERY POWERED UNITS: 9 VOLT
REMOTE POWER "RC" UNITS: 24 VOLT
USE 24 VOLT SETTING FOR USE WITH
12 VOLT DC INPUT POWER.
VOLUME SELECTOR
LOW
HI
FACTORY VOLUME SETTING: HIGH
USE ONLY
9 VOLT BATTERY
THIS JUMPER IS USED
ON STANDARD 9 VOLT
INTERNALLY POWERED
MODELS
THIS JUMPER IS THE STANDARD
INSTALLED JUMPER ON "RC" MODELS
FOR EXTERNALLY SUPPLIED 12VDC OR
24VDC POWER
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD
THIS JUMPER IS INCLUDED WITH "RC"
MODELS FOR USE WHEN INTERNAL
9VDC BATTERY POWER IS REQUIRED.
(BATTERY NOT INCLUDED)
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD
NOTE: USING THIS JUMPER REQUIRES
VOLTAGE SELECTOR SET TO 9V
STI-1103 RELAY
BOARD IS USED ON
"RC" MODELS
VOLTAGE SELECTOR
9V 24V
VOLTAGE SETTINGS:
STANDARD UNITS: 9 VOLT
"RC" UNITS: 24 VOLT
NOTE: USE 24 VOLT SETTING
FOR USE WITH 12 VOLT DC
INPUT POWER.
VOLUME SELECTOR
LOW
HI
STANDARD VOLUME SETTING: HIGH
FOR RETROFIT APPLICATIONS,
CUT GASKET AT THE BOTTOM TO
INSTALL BEHIND CONDUIT
FOR RETROFIT APPLICATIONS,
CUT GASKET AT THE BOTTOM TO
INSTALL BEHIND CONDUIT
EXPLODED
ELECTRONIC VIEW
SIDE VIEW
6.2 in.(158mm)
MODELS WITH HORN (STI-1100 Series)
COVER
5.5 in.(140mm)
8.5 in.(216mm)
3.2 in.(81mm)
2 in.(51mm)
ALL MODELS END VIEW
COVER
3.2 in.(81mm)
2 in.(51mm)
5.5 in.(140mm)
5 in.(127mm)
3 in.(76mm)
SPACER
SPACER
SIDE VIEW
7.0 in.(178mm)
MODELS WITHOUT HORN (STI-1200 AND STI-3150 Series)
COVER
6.5 in.(165mm)
8.5 in.(216mm)
3.2 in.(81mm)
2 in.(51mm)
SPACER
3 in.(76mm)
DEPTH CHART FOR STI STOPPER II
4 in.(102mm)
5 in.(127mm)
5.5 in.(140mm)
STI-3100 SPACER
ADDS 2" DEPTH(51mm)
FOR SURFACE MOUNTED
PULL STATIONS
.75 in.(19mm)
1.625 in.(41mm)
2.375 in.(60mm)
2.75 in.(70mm)
3.2 in.(81mm)
5.5 in.(140mm)
HORN HOUSING
3 in.(76mm)
ALL MODELS END VIEW
4 in.(102mm)
5 in.(127mm)
5.5 in.(140mm)
STI-3100 SPACER
ADDS 2" DEPTH(51mm)
5.5 in.(140mm)
E
.75 in.
(19mm)
1.625 in.
(41mm)
2.375 in.
(60mm)
2.75 in.
(70mm)
3.2 in.
(81mm)
A
B
C
D
E
D
C
B
A
PULL DOWN
STI-1280 BACKPLATE
INSERT
(2) PROVIDED
STI-3003 GASKET (1/2 in. CONDUIT)
STI-3004 GASKET (3/4 in. CONDUIT
AND STI-3104 SPACER)
STI-3002 WEATHER GASKET
FOR WEATHER OPTION
(USE TWO WITH SPACER)
STI-3100 CONDUIT SPACER - STANDARD SPACER
INCLUDED WITH SURFACE MOUNT UNITS
STI-3104 CONDUIT SPACER ACCOMMODATES
3/4 in. CONDUIT FOR WEATHER STOPPER
SUB-315 GRILL
SUB-316
LOUVER
*NOTE: STI SUGGESTS USING THE
STI-1280 BACKPLATE FOR WEATHER UNITS
OR WHEN MOUNTED ON AN UNEVEN SURFACE.
WALL
OPTIONAL STI-1103
RELAY BOARD
RED +9, 12, OR 24 VOLTS
BLACK -9, 12, OR 24 VOLTS
GREEN NORMALLY OPEN
BLUE COMMON
WHITE NORMALLY CLOSED
3/32 in. ALLEN WRENCH
(NOT PROVIDED)
SWITCH LOCKING SCREW
5 INCHES OF CABLE IS
PROVIDED FOR SERVICE LOOP.
MAKE SURE THIS LOOP AND
ALL OTHER CABLES DO NOT
INTERFERE WITH STATION
OPERATION.
TO LOCK POWER SWITCH IN
THE "OFF" OR "ON" POSITION
TIGHTEN LOCKING SCREW FULLY
UNTIL SCREW MAKES CONTACT
WITH SWITCH PAD AS SHOWN.
OFF
OPTIONAL RELAY CONTACT SETTINGS
STI MODELS 1100RC, 1130RC, 1150RC AND 1155RC
( NOT USED WITH 9VDC BATTERY JUMPER)
*
*
*
ADDED
SILICONE
EXISTING
PULL STATION
SCREW WITHOUT SPACER
FLUSH MOUNT
WITH OPTIONS
SURFACE MOUNT
WITH OPTIONS
ANCHOR
(4) PROVIDED
EXISTING PULL
STATION
INSERT PLASTIC KNOCK-OUT (2) PROVIDED
INTO SPACER NOTCH IF CONDUIT IS NOT NEEDED
STI-3003 GASKET (USE WITH 1/2 in. CONDUIT)
STI-3004 GASKET (USE WITH 3/4 in. CONDUIT
AND STI-3104 SPACER)
STI-3100 CONDUIT SPACER SHOWN
WITH SUB-316 AND SUB-315
FOR ADDITIONAL VENTILATION
ORDER SUB-316 LOUVER KIT
OR SUB-315 GRILL
SCREW WITH SPACER
BACKPLATE
NOTE: WHEN DRILLING HOLE IN
BACKPLATE NEMA 3R INTEGRITY
IS COMPROMISED
ADHESIVE SIDE
STI-3002 WEATHER GASKETS
INSTALL THICK END OF GASKET
TOWARDS TOP OF ASSEMBLY
STI-1280
BACKPLATE
VIEW OF RELAY CONTACT
15 - 24 VDC
9 - 12 VDC
GROUND
NORMALL OPEN
NORMALLY CLOSED
COMMON
USE ONLY
9 VOLT BATTERY
JUMPER USED ON STANDARD 9
VOLT INTERNALLY
POWERED MODELS
JUMPER INSTALLED ON "RC" MODELS
FOR EXTERNALLY SUPPLIED 12VDC OR
24VDC POWER
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD
THIS JUMPER IS INCLUDED WITH "RC"
MODELS FOR USE WHEN INTERNAL
9VDC BATTERY POWER IS REQUIRED.
(BATTERY NOT INCLUDED)
SMALL CONNECTOR ON JUMPER FITS
INTO PLUG ON RELAY BOARD
USING THIS JUMPER REQUIRES
VOLTAGE SELECTOR SET TO 9V
STI-1103 RELAY
BOARD IS USED ON
"RC" MODELS
VOLTAGE SELECTOR
9V 24V
FACTORY VOLTAGE SETTINGS:
BATTERY POWERED UNITS: 9 VOLT
REMOTE POWER "RC" UNITS: 24 VOLT
USE 24 VOLT SETTING FOR USE WITH
12 VOLT DC INPUT POWER.
VOLUME SELECTOR
LOW
HI
FACTORY VOLUME SETTING: HIGH
USE ONLY
9 VOLT BATTERY
THIS JUMPER IS USED
ON STANDARD 9 VOLT
INTERNALLY POWERED
MODELS
THIS JUMPER IS THE STANDARD
INSTALLED JUMPER ON "RC" MODELS
FOR EXTERNALLY SUPPLIED 12VDC OR
24VDC POWER
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD
THIS JUMPER IS INCLUDED WITH "RC"
MODELS FOR USE WHEN INTERNAL
9VDC BATTERY POWER IS REQUIRED.
(BATTERY NOT INCLUDED)
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD
NOTE: USING THIS JUMPER REQUIRES
VOLTAGE SELECTOR SET TO 9V
STI-1103 RELAY
BOARD IS USED ON
"RC" MODELS
VOLTAGE SELECTOR
9V 24V
VOLTAGE SETTINGS:
STANDARD UNITS: 9 VOLT
"RC" UNITS: 24 VOLT
NOTE: USE 24 VOLT SETTING
FOR USE WITH 12 VOLT DC
INPUT POWER.
VOLUME SELECTOR
LOW
HI
STANDARD VOLUME SETTING: HIGH
FOR RETROFIT APPLICATIONS,
CUT GASKET AT THE BOTTOM TO
INSTALL BEHIND CONDUIT
FOR RETROFIT APPLICATIONS,
CUT GASKET AT THE BOTTOM TO
INSTALL BEHIND CONDUIT
EXPLODED
ELECTRONIC VIEW
Polycarbonate Cleaning Instructions
Rinse with water to remove abrasive dust and dirt. Wash with soap or mild detergent, using
a soft cloth. Rinse once more, then dry with a soft cloth or chamois. Exercise caution when
using water inside enclosure. Make sure unit is completely dry inside before reassembling. To
remove grease or wet paint from exterior of cover, rub gently with a cloth thoroughly wetted
with Naptha. Then wash and rinse. (Do not use razor blades.)
Options Available
· STI-1280 Backplate for mounting appliances to uneven surface.
· STI-3002 Weather gaskets
· STI-3100 Large conduit clear 2” conduit spacer for 1/2” conduit
· SUB-315 Grill for Ventilation Kit
· SUB-316 Louvers for extra ventilation
· STI-3003 1/2” conduit gasket
· STI-3004 3/4” rigid conduit gasket
· STI-3104 Modified STI-3100 with larger top conduit opening to accommodate the
STI-3004 3/4” rigid conduit gasket.
Product Dimensions
EXTERNAL DIMENSIONS: · Flush 7.2 W x 10.2 H x 3.3 D in. (183x259x84mm)
· Surface 7.2 W x 10.2 H x 5.5 D in. (183x259x140mm)