17.3 Hot water output
The domestic hot water (DHW) output is subject to the connected
power supply, the water heater's connected load, and the cold water
inlet temperature. The rated voltage and rated output can be found
on the type plate.
Power output in kW 100 °F DHW output in gpm
Rated voltage Cold water inlet temperature
Model ĜŝƃŨp ŝƃÄŨp ŝÔƃŨp 41 °F 50 °F 59 °F 68 °F
DHC-E
3/3.5-1
Trend
3.0 0.35 0.41 0.5 0.64
3.5 0.41 0.48 0.58 0.75
DHC-E
4/6-2
Trend
2.9 0.34 0.4 0.48 0.62
4.5 0.52 0.61 0.75 0.96
3.8 0.44 0.52 0.63 0.81
6.0 0.69 0.82 1.0 1.28
DHC-E
8/10-2
Trend
5.4 0.63 0.74 0.9 1.15
7.2 0.83 0.98 1.2 1.54
7.2 0.83 0.98 1.2 1.54
9.6 1.11 1.31 1.6 2.05
DHC-E
12/15-2
Trend &
Plus
9.0 1.04 1.23 1.5 1.92
10.8 1.24 1.46 1.78 2.28
12.0 1.39 1.64 2.0 2.56
14.4 1.67 1.97 2.4 3.07
Power output in kW 122 °F DHW output in gpm
Rated voltage Cold water inlet temperature
Model ĜŝƃŨp ŝƃÄŨp ŝÔƃŨp 41 °F 50 °F 59 °F 68 °F
DHC-E
3/3.5-1
Trend
3.0 - 0.28 0.33 0.38
3.5 0.3 0.33 0.38 0.44
DHC-E
4/6-2
Trend
2.9 - 0.28 0.31 0.37
4.5 0.38 0.43 0.49 0.57
3.8 0.32 0.36 0.41 0.48
6.0 0.51 0.57 0.65 0.76
DHC-E
8/10-2
Trend &
Plus
5.4 0.46 0.51 0.59 0.68
7.2 0.61 0.68 0.78 0.91
7.2 0.61 0.68 0.78 0.91
9.6 0.81 0.91 1.04 1.21
DHC-E
12/15-2
Trend &
Plus
9.0 0.76 0.85 0.98 1.14
10.8 0.9 1.02 1.16 1.35
12.0 1.01 1.14 1.3 1.52
14.4 1.21 1.37 1.56 1.82
Power output in kW 38 °C DHW output in l/min
Rated voltage Cold water inlet temperature
Model ĜŝƃŨp ŝƃÄŨp ŝÔƃŨp 5 °C 10 °C 15 °C 20 °C
DHC-E
3/3.5-1
Trend
3.0 1.3 1.5 1.9 2.4
3.5 1.5 1.8 2.2 2.8
DHC-E
4/6-2
Trend
2.9 1.3 1.5 1.8 2.3
4.5 1.9 2.3 2.8 3.6
3.8 1.7 2.0 2.4 3.0
6.0 2.6 3.1 3.7 4.8
DHC-E
8/10-2
Trend
5.4 2.3 2.8 3.4 4.3
7.2 3.1 3.7 4.5 5.7
7.2 3.1 3.7 4.5 5.7
9.6 4.2 4.9 6.0 7.6
DHC-E
12/15-2
Trend &
Plus
9.0 3.9 4.6 5.6 7.1
10.8 4.6 5.5 6.6 8.5
12.0 5.2 6.1 7.5 9.5
14.4 6.2 7.3 8.9 11.4
Power output in kW 50 °C DHW output in l/min
Rated voltage Cold water inlet temperature
Model ĜŝƃŨp ŝƃÄŨp ŝÔƃŨp 5 °C 10 °C 15 °C 20 °C
DHC-E
3/3.5-1
Trend
3.0 1.0 1.1 1.2 1.4
3.5 1.1 1.3 1.4 1.7
DHC-E
4/6-2
Trend
2.9 - 1.1 1.2 1.4
4.5 1.4 1.6 1.8 2.1
3.8 1.2 1.4 1.6 1.8
6.0 1.9 2.1 2.4 2.9
DHC-E
8/10-2
Trend &
Plus
5.4 1.7 1.9 2.2 2.6
7.2 2.3 2.6 2.9 3.4
7.2 2.3 2.6 2.9 3.4
9.6 3.0 3.4 3.9 4.6
DHC-E
12/15-2
Trend &
Plus
9.0 2.9 3.2 3.7 4.3
10.8 3.4 3.8 4.4 5.1
12.0 3.8 4.3 4.9 5.7
14.4 4.6 5.1 5.9 6.9
17.4 Application areas/conversion table
Here, data is shown for electrical resistivity and electrical conduc-
tivity.
Standard specifica-
ŒêĒĉ|ŒĜÑŨ³
ŝƃŨ³
ŝÑŨ³
Min.
resistivity
ρ≥
Max.
conductivity ı
Min.
resistivity
ρ≥
Max.
conductivity ı
Min.
resistivity
ρ≥
Max.
conductivity ı
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
1100 91 910 970 103 1031 895 112 1117
17.4.1 Sizing the pipework
When calculating the size of the pipework, an water heater pressure
drop of 14.5 psi (0.1MPa) is recommended.
17.5 Fault conditions
In the event of a fault, temperatures up to 176 °F (80 °C) at a pressure
of 145 psi (1.0 MPa) can occur briefly in the installation.