Product Overview

Model DHC-E 3/3.5-1 Trend DHC-E 4/6-2 Trend DHC-E 8/10-2 Trend
DHC-E 8/10-2 Plus
DHC-E 12/15-2 Trend
DHC-E 12/15-2 Plus
Item no. 200057 200061 200058 (Trend)
202145 (Plus)
200059 (Trend)
200056 (Plus)
Phase
- 50/60 Hz 1
Voltage 120
V 240 V 208 V 240 V 208 V 240 V 208 V
Wattage
1
, jumper position
1 [low] / 2 [high]
3 kW / 3.5 kW 3.8 kW / 6 kW 2.9 kW / 4.5 kW 7.2 kW / 9.6 kW 5.4 kW / 7.2 kW 12 kW / 14.4 kW 9 kW / 10.8 kW
Amperage, jumper position
1 [low] / 2 [high]
25 a / 29.2 a 15.8 a / 25 a 13.9 a / 21.7 a 30 a / 40 a 26 a / 34.6 a 50 a / 60 a 43.3 a / 52 a
Min. recommended circuit breaker size
2
,
jumper position 1 [low] / 2 [high]
25 a / 30 a 20 a / 25 a 15 a / 25 a 30 a / 40 a 30 a / 35 a 50 a / 60 a 50 a / 60 a
Min. recommended AWG wire size
3
,
jumper position 1 [low] / 2 [high]
10/2 / 10/2 12/2 / 10/2 14/2 / 10/2 10/2 / 8/2 10/2 / 8/2 8/2 / 6/2 8/2 / 6/2
Minimum water ow
to activate unit
0.264
gpm (1.0 l/min)
Weight 5.5
lb (2.5 kg)
Dimensions
Height 14
1
/
8
� (360 mm) x Width 8� (202 mm) x Depth 4
5
/
16
� (109 mm)
Nominal water volume 0.07
gal (0.277 l)
Max. permissible inlet temperature
4
149 °F (65 °C)
Maximum permissible pressure 145 psi (10 bar)
Water connections ½�
NPT
DHC-E 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating ow-reducer/aerators that must be installed.
1 Factory default setting is jumper position 2 [high]
2 Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3 Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3%
under load.
4 Max input water 149°F; max input water that would be heated 131°F; max. temperature output 140°F.
These are our recommendations. Check local codes for compliance if necessary.
Tested and certified by WQA
against NSF/ANSI 372 for lead
free compliance.
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA Std. C22.2 No. 64
Technical Data
Model DHC 3/3.5-1 Trend DHC 4/6-2 Trend DHC 8/10-2 Trend DHC 12/15-2 Trend
Item no. 200060 200062 200063 200064
Phase
- 50/60 Hz 1
Voltage 120
V 240 V 208 V 240 V 208 V 240 V 208 V
Wattage
1
, jumper position
1 [low] / 2 [high]
3 kW / 3.5 kW 3.8 kW / 6 kW 2.9 kW / 4.5 kW 7.2 kW / 9.6 kW 5.4 kW / 7.2 kW 12 kW / 14.4 kW 9 kW / 10.8 kW
Amperage, jumper position
1 [low] / 2 [high]
25 a / 29.2 a 15.8 a / 25 a 13.9 a / 21.7 a 30 a / 40 a 26 a / 34.6 a 50 a / 60 a 43.3 a / 52 a
Min. recommended circuit breaker size
2
,
jumper position 1 [low] / 2 [high]
25 a / 30 a 20 a / 25 a 15 a / 25 a 30 a / 40 a 30 a / 35 a 50 a / 60 a 50 a / 60 a
Min. recommended AWG wire size
3
,
jumper position 1 [low] / 2 [high]
10/2 / 10/2 12/2 / 10/2 14/2 / 10/2 10/2 / 8/2 10/2 / 8/2 8/2 / 6/2 8/2 / 6/2
Minimum water ow
to activate unit
0.264
gpm (1.0 l/min)
Weight 5.5
lb (2.5 kg)
Dimensions
Height 14
1
/
8
� (360 mm) x Width 8� (202 mm) x Depth 4
5
/
16
� (109 mm)
Nominal water volume 0.07
gal (0.277 l)
Max. permissible inlet temperature
4
149 °F (65 °C)
Maximum permissible pressure 145 psi (10 bar)
Water connections ½�
NPT
DHC 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating ow-reducer/aerators that must be installed.
1 Factory default setting is jumper position 2 [high]
2 Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3 Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3%
under load.
4 Max input water 149°F; max input water that would be heated 131°F; max. temperature output 140°F.
These are our recommendations. Check local codes for compliance if necessary.
Tested and certified by WQA
against NSF/ANSI 372 for lead
free compliance.
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA Std. C22.2 No. 64
Technical Data
DHC Trend
Mechanical models:
Thermostatic models :
Mini
2-1 231045
Mini
-E 2-1 236011
Mini
2.5-1 232098
Mini
-E 2.5-1 236135
Mini
3-1 220816
Mini
-E 3-1 236010
Mini
3.5-1 232099
Mini
-E 3.5-1 236136
Mini
4-2 222039
Mini
-E 4-2 236009
Mini
6-2 220817
Mini
-E 6-2 236008
Phase - 50/60 Hz
1
Voltage
1
120 V 120 V 120 V 120 V 240 V or 208 V 240 V or 208 V
Wattage
1.8 kW 2.4 kW 3.0 kW 3.5 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW
Amperage draw
15 A 20 A 25 A 29 A 15 A 13 A 24 A 21 A
Min. recommended
circuit breaker size
2
15 A (Sp) 20 A (Sp) 25 A (Sp) 30 A (Sp) 15 A (Dp) 25 A (Dp)
Min. recommended
wire size
3
(copper)
14/2 AWG 12/2 AWG 10/2 AWG 10/2 AWG 14/2 AWG 10/2 AWG
Min. fl ow to activate
Mechanical units
0.21 gpm (0.8 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.77 gpm (2.9 l/min)
Thermostatic units
0.21 gpm (0.8 l/min) 0.30 gpm (1.15 l/min) 0.30 gpm (1.15 l/min) 0.30 gpm (1.15 l/min) 0.30 gpm (1.15 l/min) 0.48 gpm (1.8 l/min)
Water temp. range Electronic units are adjustable from 86122 °F (30–50 °C)
Energy Factor (EF)
(Mechanical / Thermostatic)
0.98 / 0.97 (UeF) 1.0 / 0.99 0.99 / 0.99
0.99 / 0.99 0.99 / 1.0 0.99 / 1.0
Weight 3.44 lb (1.56 kg)
Dimensions
Width 7½˝ (19.0 cm) x Height 6½˝ (16.5 cm) x Depth 3¼˝ (8.2 cm)
Water volume in unit 0.026 gal (0.1 l)
Minimum pressure 30
psi (2 bar)
Working pressure 150 psi (10 bar)
Tested to pressure 300 psi (20 bar)
Water connections
4
3
/
8
˝ O.D. flexible braided stainless steel hose connectors
Mini
2-1 is internally restricted to 0.32 gpm (1.2 l/min). Mini
-E 2-1 is internally restricted to 0.40 gpm (1.5 l/min).
All Mini
models ship with appropriately sized pressure compensating fl ow-reducer/aerators that must be installed.
1
Nominal mains voltage is 110120 V and 220240 V.
2
This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heaters are considered a non-continuous load.
3
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
4
Mechanical units suitable for supply with cold water only. Thermostatic units can accept inlet water of 122 °F.
Tested and certified by WQA
against NSF/ANSI 372 for
lead free compliance.
Certified to ANSI/UL Std. 499
Mini
: Conforms to CAN/CSA E335-1 & E335-2-35
Mini
-E: Conforms to CAN/CSA Std. C22.2 No. 64
Technical Data
DHC 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating flow-reducer/aerators that must be installed.
1 Factory default setting is jumper position 2 [high]
2 Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3 Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3%
under load.
4 Max input water 149°F; max input water that would be heated 131°F; max. temperature output 14F.
These are our recommendations. Check local codes for compliance if necessary.
DHC-E 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating flow-reducer/aerators that must be installed.
1 Factory default setting is jumper position 2 [high]
2 Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3 Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3%
under load.
4 Max input water 149°F; max input water that would be heated 131°F; max. temperature output 14F.
These are our recommendations. Check local codes for compliance if necessary.