4
2.4 INSTALLING PERMANENT WIRING
If permanent wiring is required by local codes, the following
procedure must be performed.
WARNING
DISCONNECT FREEZER FROM THE SOURCE
OF ELECTRICAL SUPPLY BEFORE SERVICING.
A. Remove the right side and left panels and electrical box
covers to gain access to the power cord.
B. Remove the strain relief connector from the bottom of
the freezer base cut and remove the power cord.
C. Install permanent wiring according to local code.
D. Connect black wire to black wire. Connect the white
wire to white wire. Connect the green or yellow and
green striped ground wire to the grounding screw.
E. Replace all covers and panels.
Figure 4. Electrical Box