SDS

Safety Data Sheet
According to HCS-2012 APPENDIX D TO ยง1910.1200
Version: 1.0/EN
Revision date: 29/04/2015
Product name: Lithium ion battery
Issue date: 26/09/2017
Report No.: NCT17038283S1-1 Page 3 of 10
No information available.
(d) Unknown Toxicity
10% of the mixture consists of ingredient(s) of unknown toxicity.
(e) Other information
No information available.
(f) Interactions with Other Chemicals
No information available.
3. Composition/information on ingredients
(a) Mixtures information
Chemical name
CAS No.
Concentration%
Cobalt lithium manganese nickel oxide
182442-95-1
40
Graphite
7782-42-5
18
Phosphate(1-), hexafluoro-, lithium
21324-40-3
18
Copper
7440-50-8
10
Iron
7439-89-6
5
Aluminum
7429-90-5
5
Polyvinyl chloride
9002-86-2
2.5
1,1-Difluoroethylene polymer
24937-79-9
1
Nickel
7440-02-0
0.5
4. First-aid measures
(a) Description of first aid measures
General Advice First aid is upon rupture of sealed battery.
Eye contact:
Show this safety data sheet to the doctor in attendance.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep
eye wide open while rinsing. Remove contact lenses, if present and easy to do. Continue
rinsing. Get medical attention if irritation develops and persists. Do not rub affected area.
Skin contact:
Remove contaminated clothes and rinse the skin with plenty of water. Get medical advice /
attention if you feel unwell.
Inhalation:
Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, (trained
personnel should) give oxygen. Get medical advice / attention if you feel unwell.
Ingestion:
Rinse mouth immediately and drink plenty of water. Never give anything by mouth to an
unconscious person. Do NOT induce vomiting. Get medical aid.
Self-protection of
the first aider
Ensure that medical personnel are aware of the material(s) involved, take precautions to
protect themselves and prevent spread of contamination.
(b) Most important symptoms/effects, acute and delayed