Design Guide

98 | Sub-Zero Customer Care 800.222.7820
Plumbing Requirements
For ease of installation, recess the water shut o into the
wall or place it in an adjacent cabinet. Locate the water
supply as shown in the illustration below. Connect the
water supply line to the house supply with an easily acces-
sible shut-o valve. Do not use self-piercing valves. An
in-line filter is required when water conditions have a high
sediment content.
IMPORTANT NOTE: A reverse osmosis system can be used
provided there is constant water pressure supplied to the
unit at all times as indicated in the chart below. A copper
line is not recommended for this application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply Line ⁄" OD copper, braided
stainless steel, or PEX tubing
Water Pressure 20–80 psi (1.4–5.5 bar)
Excess Water Line for Connection 36" (914)
ICE MAKER DRAIN
Ice maker models can be ordered with or without a drain
pump. Models without a pump will drain water by gravity.
A drain must be installed.
The drain and inlet water tubes must be plumbed before
connecting to the ice maker. For the gravity drain, horizon-
tal drain lines must have a ⁄"
(6) per 12" (305) fall. An air gap
will likely be required between the unit and drain. A stand
pipe with a trap below is acceptable for the drain.
34
1
/2" (876)
ROUGH
OPENING
HEIGHT
33
5
/8" (854)
MINIMUM
HEIGHT
REQUIRED
15
1
/4"min (387)
ROUGH
OPENING WIDTH
24" (610)
ROUGH
OPENING
DEPTH
POSITION OUTLET
WITH GROUNDING
PRONG ON RIGHT
LOCATION OF
WATER LINE
8"
(203)
1
/2"
(
13
)
TOP VIEW
FRONT VIEW
4"
(
102
)
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
Water supply location
Electrical Requirements
Locate the electrical supply as shown in the illustration
below. A separate circuit servicing only this appliance is
required.
IMPORTANT NOTE: For indoor models, a ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause
interruption of operation.
For the outdoor model, a ground fault circuit interrupter
(GFCI) is required to reduce the risk of electrical shock.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
E
E
LOCATE
ELECTRICAL
SUPPLY IN
ADJACENT
CABINET
Electrical supply location
Undercounter Ice Maker