8.3 Correction factors
Correction factor for operating pressure changes:
Inlet air pressure psig
60
80
100
120
140
160
180
200
barg
4.1
5.5
6.9
8.3
9.7
11.0
12.4
13.8
Factor (F1)
0.79
0.91
1.00
1.07
1.13
1.18
1.23
1.27
Correction factor for ambient temperature changes:
Ambient temperature ºF
80
90
100
105
110
115
ºC
27
32
38
41
43
46
Factor (F2)
1.12
1.09
1.00
0.93
0.85
0.75
Correction factor for inlet air temperature changes:
Air temperature ºF
80
90
100
110
120
130
ºC
27
32
38
43
49
54
Factor (F3)
1.24
1.23
1.00
0.81
0.66
0.54
How to find the air flow capacity:
Air flow capacity = Nominal duty x Factor (F1) x Factor (F2) x Factor (F3)
Example:
An SRT 30 AC 115V T cUL has a nominal duty of 30 scfm (51 m³/h). What is the maximum allowable flow
through the dryer under the following operating conditions?
Inlet air pressure = 100 psig (6.9 barg)
Ambient temperature = 90°F (32°C)
Inlet air temperature = 110°F (43°C)
Factor (F1) = 1.00
Factor (F2) = 1.09
Factor (F3) = 0.81
Each item of data has a corresponding numerical factor which multiplied by the design air flow is as follows:
Air flow capacity = 30 x 1.00 x 1.09 x 0.81 = 26 scfm (44 m³/h)
26 scfm (44 m³/h) This is the maximum flow rate that the dryer can accept under these operating conditions.
How to select a suitable dryer for a given duty:
Minimum std. air flow rate =
Design air flow
Factor (F1) x Factor (F2) x Factor (F3)
Example:
With the following operating parameters:
Design air flow = 40 scfm (68 m
3
/h)
Inlet air pressure = 100 psig (6.9 barg)
Ambient temperature = 105°F (41°C)
Inlet air temperature = 100°F (38°C)
Factor (F1) = 1.00
Factor (F2) = 0.93
Factor (F3) = 1.00
In order to select the correct dryer model the required flow rate is to be divided by the correction factors
relating to above mentioned parameters:
Minimum std. air flow rate =
40
= 43 scfm (73 m³/h)
1.00 x 0.93 x 1.00
Therefore, the model suitable for the conditions above is SRT 60 AC 115V T cUL (60 scfm [102 m³/h] -
nominal duty).