8.4 Connection to the compressed-air system
Danger!
Compressed air!
All works must only be carried out by qualified skilled personnel.
Never work on compressed-air systems which are under pressure.
The operator or the user must ensure that the dryer is never operated with a pressure exceeding the
maximum pressure value indicated on the name plate.
Exceeding the maximum operating pressure can be dangerous for the operator but also for the device.
The air temperature and the air flow at the inlet of the dryer must lie within the limit values indicated on the name plate.
The connecting lines must be free from dust, iron rust, shards and other contaminations and correspond to the flow rate
of the dryer. Should air with a very high temperature be treated, the installation of an aftercooler may be necessary. For
the implementation of maintenance works, the installation of a bypass system is recommended.
The dryer was designed in such a manner that vibrations that may occur during operation are limited. Therefore, it is
advisable to employ connecting lines (flexible hoses, vibration-inhibiting fittings etc.) which protect the dryer against
possible vibrations in the pipework.
===== Ende der S tückliste ==== =
Note!
Contaminated intake air!
If the intake air is strongly contaminated (ISO 8573.1 class 3.-3) or poorer quality, we recommend the
additional installation of a prefilter (e.g. Sullair SXT or SXF), to avoid clogging of the heat exchanger.
8.5 Electrical connections
Danger!
Supply voltage!
The connection to the electric mains should only be carried out by qualified skilled personnel and must
correspond to the legal provisions in force in your region.
Prior to connecting the device, please check the name plate to avoid exceeding the indicated values. The voltage
tolerance is +/- 10%.
SRT 15-80 AC 115V T cUL dryers are supplied with a power cord and safety plug (two-pole and earth connection).
Make sure that suitable fuses or circuit breakers in accordance with the indications on the name plate are available.
A residual-current device (RCD) with In =0.03A is suggested. The cross-section of the power supply cable must
correspond to the power consumption of the dryer. In this respect, the ambient temperature, the cable laying conditions,
the length of the cables and the requirements of the local electricity supplier need to be considered.
Danger!
Supply voltage and missing earth connection!
Important: ensure that the plant is connected to earth.
Do not use plug adapters at the power plug.
Possible replacement of the power plug must only be carried out by a qualified electrician.