Product Manual

User Manual US-EN SR 10-480 AC
02250246-045 R02
41
Subject to EAR. ECCN EAR99 and related export control restrictions.
If installed:
the TS safety
temperature switch
was triggered.
Check which of the following reasons is responsible for the triggering:
Excess thermal load re-establish the standard operating conditions.
The inlet air is too hot re-establish the nominal conditions.
The ambient temperature is too high or the room ventilation insufficient ensure sufficient
ventilation.
The condenser unit is dirty please clean it.
The fan does not work see the corresponding point.
The hot-gas bypass valve needs to be re-adjusted contact a specialist for refrigerating
plants to have the nominal calibration re-established.
There is a leak in the refrigeration cycle please contact a SULLAIR service technician.
Reset the temperature switch by manually pushing the button on the temperature switch check
the perfect functioning of the dryer.
The TS temperature switch is defective replace it.
Electronic instrument
DMC15 The first and
the last led of display
are flashing
syncronous.
Verify the electric wiring of T1 DewPoint probe.
The T1 DewPoint probe is faulty - replace it.
The electronic instrument is faulty - replace it.
Electronic instrument
DMC15 The
yellow led is flashing
SR 10-100 - Verify the electric wiring of T2 fan control probe.
SR 10-100 - The T2 fan control probe is faulty - replace it.
SR 125-480 - Verify the electric wiring of resistance on terminal 1 and 2
The electronic instrument is faulty - replace it.
Electronic instrument
DMC15 The first led of
the display is flashing
DewPoint too low - see specific point.
The T1 DewPoint probe is faulty - replace it.
The electronic instrument is faulty - replace it.
Electronic instrument
DMC15 The last led of
the display is flashing
DewPoint too high - see specific point.
The T1 DewPoint probe is faulty - replace it.
The electronic instrument is faulty - replace it.
12.3 Recommended spare parts
Spare parts list is printed on a dedicated sticker applied inside the dryer. On this sticker each spare part is identified
with its ID Number and related Spare Part Number. Here below the cross-reference table between ID Numbers and
exploded drawings Ref. with their description and quantity installed in the dryers.
NOTE: To order the recommended spare parts or other elements, the data on the name plate must be
indicated.