Brochure

Model #
FLOW RATE
(scfm)
CONNECTION
SIZE (NPT)
PRESSURE
DROP (psid)
Power Consumption
— Load (kW)
Height
(
in
)
Width
(
in
)
Depth
(
in
)
Weight
(
lbs
)
SRHT 20 20 ½˝ 1.5 0.21 25 17 16 82
SRHT 30 30 ½˝ 2.8 0.28 25 17 16 88
SRHT 40 40 ½˝ 2.9 0.31 25 17 16 90
SRHT 50 50 ½˝ 4.1 0.46 25 17 16 93
SRHT 75 75 3.8 0.77 45 16 18 112
SRHT 100 100 1¼˝ 3 0.88 52 20 20 134
SRHT 150 150 1¼˝ 5 1.1 52 20 20 146
SRHT 200 200 1½˝ 3.3 1.55 55 22 23 165
SRHT 250 250 1½˝ 5.1 1.82 55 22 23 185
SRHT 300 300 4.1 2.6 59 28 31 291
SRHT 350 350 4.5 2.7 59 28 31 304
SULLAIR Refrigerated HIGH TEMPERATURE Dryers
SRHT series
FREQUENCY: 60 Hz
The Sullair symbol and Sullair wordmark are registered trademarks of Sullair, LLC.
Capacity correction factors for differing ambient air temperatures
Ambient Air Temperature°F 80 90 100 105 110 115 120
Correction Factor 1.22 1.11 1 0.94 0.89 0.83 0.78
Capacity correction factors for differing inlet air temperatures
Inlet Air Temperature °F 140 160 170 180 195 210
Correction Factor 1.26 1.13 1.07 1 0.9 0.81
Capacity correction factors for differing Operating pressure
Operating Pressure psig 60 80 100 120 140 160 180 200
Correction Factor 0.79 0.91 1 1.07 1.13 1.18 1.23 1.27
Integrated aftercooler
Pre-filter included
Certified to UL/CSA standards
Standard Operating Voltage
SRHT 20–150 115V/1PH
SRHT 200350 230V/1PH
Recommended post-filtration μm 0.01
Standard outlet pressure dew point °F 45–50
ISO 8573-1:2010 Air Quality Class Class 6
Max inlet air temperature°F 210°F
Min/max ambient temperature°F 34°F/ 120°F
Max inlet pressure psig 200
* At 45°F Outlet PDP
© 2019 Sullair, LLC. All rights reserved. Specifications including appearance subject to change without notice. SAPATREFSPECNC201904-2