Brochure

FREQUENCY: 60 Hz
Capacity correction factors for differing ambient air temperatures
Ambient Air Temperature °F 80 90 100 105 110 115 120
Correction Factor 1.1 1.09 1 0.94 0.87 0.78 0.69
Capacity correction factors for differing inlet air temperatures
Inlet Air Temperature °F 90 100 110 120 130 140 150 160
Correction Factor 1.16 1 0.82 0.68 0.61 0.52 0.45 0.4
Capacity correction factors for differing Operating pressure
Operating Pressure psig 60 80 100 120 140 160 180 200
Correction Factor 0.79 0.91 1 1.07 1.13 1.18 1.23 1.27
Required pre-filtration μm 1
Recommended post-filtration μm 0.01
SR
+
20–200 (115V) Certified to UL/CSA Standards
SR
+
125–500 (230V) Certified to UL/CSA Standards
SR
+
600–10,000 cULus Certified Control Panel
Standard Operating Voltage
SR
+
20–200 115V/1PH
SR
+
200–400 230V/1PH
SR
+
250–10,000 460V/3PH
Optional Operating Voltage 575V
Standard outlet pressure dew point °F 37–45
ISO 8573-1 2010 Air Quality Class Class 4–5
Max inlet air temperature°F 160
Min/max ambient temperature°F 34/120
Max inlet pressure psig
SR
+
20–50 232
SR
+
75–500 200
MODBUS ready *