Full Product Manual

SECTION 2 SHOPTEK
USER MANUAL
19
02250180-090 R00
The lower line will display the cause of the fault.
Refer to service instructions to correct the cause.
Press and hold the Return/Reset pad to reset
the controller.
Refer to Figure 2-11. Press the Down arrow to
display additional information about the compressor.
The upper line will indicate the name of the
temperature, pressure, or other measurement. The
lower line indicates the present reading.
Figure 2-11
Refer to Figure 2-12. When you continue beyond the
status information, the display will show a list of
control settings. There are customer and factory
settings. The upper line will indicate the name of the
setting. The lower line displays the present value.
Figure 2-12
Refer to Figure 2-13 and 2-14. To change a selected
setting press and an interface will display where
a password is needed. Use and to change
values of each digit. Use to move to next digit.
After all digits of the password have been accepted,
press . Upon acceptance of password, the
setting can be modified. Use buttons as above to
change values. Press to accept
changes.
Figure 2-13
Figure 2-14
Refer to Figure 2-14. If there is no keypad activity,
the display will return to normal view in about one
minute. If the Start, Stop or Return/Reset buttons are
pressed, the display also returns to normal view. If
any of these occur, the setting will not be altered.
If there are any warnings or recommended service
instructions, these will be periodically displayed on
the normal view.
The list of displays may be navigated from either
direction by using the Up or Down arrow
keys.
The Emergency Stop button located near the
controller overrides all electronic functions to turn off
the control devices. The controller senses this and
will display E-stop. To reset, twist and pull out the
Emergency Stop button.
2.9 LED LIGHTS
The three LED lights indicate the general conditions
of the machine.
The Power indicator indicates power is supplied
to the controller.
The Run mode indicator indicates compressor
operation is enabled. It lights steadily if the motor is
running.
The red Fault indicator indicates that a
compressor fault has occurred and needs to be
repaired before further operation. The text display
will indicate the cause of the fault.
TOTAL RUN TIME:
337H 20M
LOAD PRESS:
0110PSI
S
S
PASSWORD ******
LOAD PRESS:
0110PSI