Full Product Manual

SECTION 3 SHOPTEK
USER MANUAL
23
02250180-090 R00
3.5 LUBRICATION CHANGE RECOMMENDATIONS AND
MAINTENANCE, FLUID FILTER AND SEPARATOR
LUBRICANT FLUID CHANGE FILTER CHANGE SEPARATOR CHANGE
Sullube (I) A B C
A - 8000 hours or 1 year, whichever occurs first.
B - 2000 Hours
C - 4000 Hours
(I) ST400, ST500, ST700 - 1 Gallon (4 Liters)
ST1100, ST1500 - 1.3 gallon (5 Liters)
Figure 3-1: Fluid Fill Location
1. Separator Tube 3. Fluid Fill Port
2. Sight Glass 4. TO DRAIN-disconnect oil line from cooler
NOTE
When performing a fluid
change or topping off:
With machine off, fill to
the bottom of the fill port.
Sight glass will be com-
pletely full.
Mixing, changing or add-
ing other lubricants within
the compressor unit may
void the air-end warranty.