Full Product Manual

SHOPTEK
USER MANUAL SECTION 6
58
02250180-090 R00
6.3 MAINTENANCE EVERY 2000
HOURS
After 2000 hours of operation:
1. Clean the return line strainer. Refer to Figure
6-1 and Figure 6-2.
2. Replace the fluid filter. Refer to Figure 6-3
and Section 6.5.
3. Pull fluid sample for analysis.
4. Replace air filter. Refer to Figure 6-4 and
Figure 6-5 and Section 6.6.
5. Check belt tension. Re-tension or replace as
necessary. Refer to Section 6.8.
6.4 FLUID MAINTENANCE
Drain the separator tube and change the compressor
fluid using instructions shown in the Lubrication
Guide.
6.5 FILTER MAINTENANCE
Refer to Figure 6-3. Replace the fluid filter under any
of the following conditions, or whichever occurs first:
1. Every 2000 hours a display on the Controller
indicates the need for replacement
2. Every fluid change.
FLUID FILTER REPLACEMENT
Refer to Figure 6-3.
1. Use a strap wrench to remove the filter and
gasket.
2. Dispose of filter properly.
3. Clean gasket seating surface.
4. Apply a light film of fluid to the filter gasket.
5. Hand tighten until gasket is seated.
6. Continue tightening filter an additional 1/2 to
3/4 turn.
7. Replace any lost fluid. Do not overfill.
8. Restart compressor and check for leaks.
Figure 6-2: Return Line Strainer
ST1100, ST1500, 15-20HP
1. Strainer
2. Separator Tube
NOTE
Dispose of fluids in accordance with
applicable federal, state and local
regulations.
Figure 6-3: Fluid Filter Assembly
1. Fluid Filter