Installation Instructions and Manual

10
1. Prepare a leak testing solution of soapy
water by mixing in a spray bole one part
liquid soap to one part water.
2. Open the valve (shut-off or LP tank).
3. Apply liquid soapy solution to all joints and
connections using a spray bole or brush.
4. Observe all joints for the presence of
bubbles. Bubbles forming indicate a gas
leak.
5. If there are no bubbles (leaks) in the gas
delivery system, close the gas supply valve.
Your grill is ready to use.
6. Re-tighten the connection(s) where bubbles
are forming.
7. Repeat steps 3-5 above.
8. If you cannot repair the leak: Make sure all
control knobs are in the full OFF position.
9. Shut off the gas supply to the grill and
release pressure in the hose and manifold
by pushing in and turning any of the control
valves one quarter turn counter-clockwise.
10. On LP systems, disconnect the cylinder from
the grill.
11. Call an authorized gas appliance service
technician or an LP gas dealer.
12. Do not use the appliance until the leak is
corrected.
OPERATION
DANGER! NEVER USE AN OPEN FLAME TO
CHECK FOR LEAKS.
As a safety precaution, remember to always leak test
your grill outdoors in a well ventilated area. Never
smoke or permit sources of ignition in the area while
performing a leak test.
WARNING!
When cooking using solid fuels such
as charcoal in this grill, DO NOT
FILL THE CHARCOAL TRAYS ABOVE
THE INDICATED MAXIMUM LEVEL.
Overfilling WILL result in overheating
of the grill and can result in death,
explosion, or fire.
• All gas grills will get hot during use.
Use extreme caution when operating
the grill. Do not touch hot surfaces
without your protective hi-temp gloves.
• Always use the handle to open or
close the grill.
• Never light the grill with the hood
closed and be certain that the burners
are positioned and seated over the gas
valves and on the burner support.
• Never lean over the cooking surface
when lighting or operating the grill.
• Always use your hi-temp grilling
gloves when operating the grill.
• Close supervision is necessary when
this or any appliance is used near
children. Keep children away from the
grill during operation and until the grill
has cooled off.
• Do not store any LP cylinder or tank
not connected for use with the grill
in the area of this grill or any other
appliance. Never store an LP cylinder
or tank indoors or within the reach of
children.
Keep any electrical supply cord and
fuel supply hose away from any heated
surfaces and dripping grease.
Do not twist the gas supply hose.
Before each use, visually inspect the
gas supply hose for cracks, cuts or
excessive wear. Replace the hose if
necessary.
Children should never be le alone or
unaended in an area where a grill is
located. Place your grill well away from
areas where children play. Do not store
items that may interest children in or
NOTE!
All gas piping and connections must
be tested for leaks aer installation
or service. All leaks must be corrected
immediately.
Homeowners should only check for
gas leaks in the external gas piping
system from the gas supply to the
gas regulator. Leak testing of the gas
valves or interior gas connections
must be tested by a qualified
technician.
OPERATION
be performed aer installation due to possible
mishandling during shipping or installation.
Periodic leak tests are recommended for safety.