USER INSTRUCTIONS COMMERCIAL FREEZERS & COOLERS UL udg.
Operating instructions Commercial Freezer/Cooler. In order to get the max. advantage from your freezer/cooler it is important that it is placed in the correct position. This manual should therefore be read carefully. Keep the manual in a place where it can always be found for reference. Even with careful attention to the freezer, a mishap may occur, with the consequence that the contents of the cabinet could be lost, therefore a product insurance is recommended. Placing the freezer/cooler.
Please note: After the lid has been opened, there will be a vacuum created inside the freezer due to the low temperatures. Wait a few minutes before trying to reopen the lid otherwise the handle could be damaged. Cleaning of sliding tracks. The dust from the sliding track is easily removed with a vacuum cleaner. Defrosting. In order for the freezer to work to its maximum efficiency the cabinet should be defrosted when a approx. 2mm thick ice layer has formed inside the cabinet.
Dixell controller. Before useBefore use Enter the programming mode by pressing the SET and arrow down keys for 3 seconds. Select the parameter “Ot” by pressing arrow up or down key. Press the SET key to display its value. Use arrow up or down to change its value. The offset can be adjusted to +/- 12 dgr .C Functions. Press SET to store the new value. How to see the set point: 1. Press and immediately release the SET key, the display will now show the set point value. 2.
Trouble shooting. N.B. There will be no compensation for incorrect use. If the freezer has stopped working, please check the following before calling for service: Service. Has the freezer been switched of at the mains? Before calling a service engineer, please check: Is the fuse blown? Not freezing/cooling. Is the plug properly in place? Please check the electricity supply and the fusing. Is the thermostat set correctly? Temperature to high inside the cabinet.
4 5 7 8 12 Fan 11 Dixell Controller Censor OR 1 3 5 7 10 Beta Controller 12 Censor Starting relay Compressor Wiring diagram. Counter-Top Comp.
Fan 4 7 8 Internal light 5 11 Dixell Controller Censor Frame Heater 12 3 4 6 Mechanical thermostat 1 3 5 7 10 Beta Controller 12 Fan Censor Starting relay Compressor Power suplay 115V 60 HZ Comp. SC15G, SC12G, SC10, CL,SC12CL, FF8,5GX, FF7,5GX, FF6GK, FF7,5GK Wiring diagram.
Fan 4 7 8 Internal light 5 11 Dixell Controller 12 Censor 1 3 5 7 10 Beta Controller 12 Fan Censor RC Compressor Wiring diagram.
Fan 4 7 8 Internal light 5 11 Dixell Controller 12 Censor 1 5 7 10 12 Fan Censor Compressor Commercial units:Chest coolers & Chest freezers 3 Beta Controller Wiring diagram.
Fan 4 7 8 Internal light 5 11 Dixell Controller 12 Censor OR 1 5 7 10 12 Fan Censor Compressor Commercial units:Chest coolers & Chest freezers 3 Beta Controller Wiring diagram.