StorageTek Installation Manual
Table Of Contents
- Summary of Changes
- Contents
- Figures
- Tables
- Preface
- Safety
- Seguridad
- Hardware Installation
- Quick Installation Procedure
- Standard Installation Procedure
- Preparing for the Installation
- Unpacking the Library
- Inspecting the Library and Drives
- Preparing the Installation Location
- Positioning the Library
- Choosing SCSI HVD or LVD
- Installing the External Fibre Channel Router
- Connecting the External SCSI Cables
- Connecting Fiber and SCSI Cables
- Attaching the Personality Module
- Attaching the Cell Barrier Clip
- Inserting the Cartridges
- Drive Compatibility Issues
- Installing the Drives
- Powering-on the Library and Drives
- Recording the Configuration Information
- Locations, Specifications, and Cables
- SNMP
- Index
Standard Installation Procedure
1-10 Revision L 96053
The library uses the power cable’s ground point for its earth-ground connection. All
electrical connections, either directly to the wall or to a power strip in the rack, must be
properly grounded. Consider proper electrical circuit and power strip overload
protection.
Note: The rack can be ordered from Sun StorageTek or from another vendor. The
StorageTek conversion bill number for the black rack is YXL20/40/80-SHELF.
To install the library in a rack:
1. Install the brackets or tray onto the rack if not previously done. The tray must be at
least 749.3 mm (29.5
in.) deep.
WARNING:
Possible personal injury: Check the path to the intended location and
clear it of obstructions before you move the library. Use at least two
people and a mechanical device to lift and position the library. The
library weighs 44.45 kg (98 lb) plus the weight of the drives. Depending
upon the drive type, each drive weighs between 5.0 kg (11 lb) and 5.5 kg
(12 lb).
ADVERTENCIA:
Posibilidad de lesiones físicas: Antes de mover la biblioteca, verifique el
trayecto hasta la ubicación de instalación prevista y retire cualquier
obstáculo. Para levantar la biblioteca y colocarla en su posición se
requieren como mínimo dos personas. La biblioteca pesa 44,45 kg (98
lb), a lo que hay que añadir el peso de las unidades. En función del tipo
de unidad, cada unidad pesa entre 5,0 kg (11 lb) y 5,5 kg (12 lb).
WARNING:
Tip hazard: When installing the library, be careful to keep the rack from
tipping over.
ADVERTENCIA:
Peligro de vuelco. Al instalar la biblioteca, tenga cuidado de que el
bastidor no se vuelque.
CAUTION:
Equipment damage: Do not grip the library by the power supply handles
or by the fans.
2. Slide the library onto the previously installed supporting brackets or tray.
Note: You must remove the front door and decorative cover over the operator panel to
access the holes in the library flanges.
3. Insert the key into the lock on the door, and unlock and open the door.
4. Hold the door firmly with your left hand and remove the bottom hinge pin, then the
top hinge pin.