StorageTek Installation Manual

Table Of Contents
96053 Revision L 2-7
Specifications
Library Power
The following table lists the power specifications for the library without drives.
Drive and Cartridge Weights
The following table lists the drive and cartridge weights. Refer to the drive publication
and vendor Web site for updated information.
Wet bulb (maximum,
noncondensing)
+29.2ºC
+84.5ºF
+35ºC
+95ºF
+35ºC
+95ºF
Altitude -76 to 3,048 m (-250 to 10,000 ft)
Table 2-1. Library Environment Specifications (Continued)
Item Measurements
Operating Storage Transporting
Table 2-2. Library Power Specifications
Input voltage 100–240 VAC, single phase
Frequency 50/60 Hz
Maximum library power consumption 1.42 A at 120 V or 0.75 A at 240 V
Maximum heat output 614 Btu/hr
Voltage-amperes 180 VA
Table 2-3. Drive and Cartridge Weights
Item Weight
DLT drive and tray 5.4 kg (12 lb)
DLT1 drive and tray 2.72 kg (6 lb)
Super DLT drive and tray 3.17 kg (7 lb)
DLT/DLT1/Super DLT cartridge 223 g (7.9 oz)
HP Ultrium LTO drive and tray 5.0 kg (11 lb)
IBM Ultrium LTO drive and tray 5.8 kg (12.7 lb)
Seagate Ultrium LTO drive and tray 5.5 kg (12 lb)
Ultrium 100 GB cartridge 220 g (7.8 oz)