User's Manual

Chapter 5 Configuring the Preinstalled Windows Server 2003 R2 Operating System 61
Note Configuring the Sun Fire X4150 server RAID is optional, by default, the
preinstalled Windows Server 2003 R2 image is configured in a non-RAID
configuration. If anything other than a basic Mirror RAID is required, it is
recommended to perform a fresh install of the Windows Server 2003 R2 OS in the
desired RAID configuration.
RAID Drive Options
TABLE 5-2 shows the RAID drive options:
TABLE 5-2 RAID Drive Options
SAS Card Drives Suppor ted RAID Configuration Suppor ted Drive Usage
Sun StorageTek Seagate 73 GB SAS Volume 1 disk
Fujitsu 73 GB SAS RAID 0 stripe 2 disk minimum No redundancy
Seagate 146 GB SAS RAID 1 mirror 2 disk minimum 50%
RAID 1E 3 drive minimum 50%
RAID 4 drive minimum 50%
RAID 5 3 drive minimum 67–94%
RAID 5EE 4 drive minimum 50–88%
RAID 50 6 drive minimum 67–94%
RAID 6 4 drive minimum 50–88%
RAID 60 8 drive minimum 50–88%
Spanned Volume 2 drive minimum 100%
RAID Volume 4 drive minimum 50-100%
LSI 3081E Seagate 73 GB SAS IM Integrated Mirror array. 2 disk
minimum, plus up to 2 hot spare disks.
Data on Primary disk
might be merged.
Fujitsu 73 GB SAS IME – Integrated Mirror Enhanced array. 3
to 8 disks including up to 2 hot spares.
All data will be deleted
during creation.
Seagate 146 GB SAS IS – Integrated Striping array. 2 to 8 disks. All data will be deleted
during creation.