Installation Instructions

LOW VOLTAGE WIRING:
Refer to the wiring diagram below for electrical connections. It is recommended that you leave at least 1’ (30 cm) of slack wire at each component wired to ease future servicing.
MAINTENANCE
Suncourt® recommends that you clean your damper at regular intervals to keep it free from lint, dust and debris. The damper must never be exposed to temperatures over
140°F (60°C).
OPERATING INSTRUCTIONS - THERMOSTATIC CONTROL WITH (ZCXXX) NORMALLY CLOSED DAMPER
1. Set the switch on the thermostat marked 'ON-AUTO' , 'ON-OFF-AUTO', 'ON-OFF' or similar wording, to the 'ON or AUTO' position.
2. Heating Season: Set the thermostat to 'HEAT'. Then adjust the thermostat to the chosen temperature (e.g. 55°F) (13°C). As long as the temperature in the room is 55°F
(13°C) or higher, the damper will be closed. If the temperature in the room falls below 55°F (13°C), the damper will open and the room will now receive heated air when the
furnace is running.
3. Cooling Season: Set the thermostat to 'COOL'. Then adjust the thermostat to the chosen temperature (e.g. 85°F) (30°C). As long as the temperature in the room is 85°F
(30°C) or lower, the damper will remain closed. If the temperature in the room goes higher than 85°F (30°C), the damper will open and the room will now receive cooled air
when the central air conditioner is running.
THREE YEAR LIMITED WARRANTY
Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the ZoneMaster™ Motorized Adjustable Damper will, for 3 (three) years from date of original retail
purchase, remain free from appearance of defects in workmanship or materials. This warranty is subject to the following limitations: (a) manufacturer’s liability is limited to the
replacement or repair of the unit, as decided by the manufacturer; (b) a defective unit must be returned, prepaid, with proof of purchase, well packaged to avoid damage in transit;
and (c) this warranty does not apply to defects resulting from the alteration, abuse, accidental damage, unauthorized repair, or misuse of the unit. This warranty is given in lieu of
all other warranties, guarantees, and conditions on manufacturer’s part, and the manufacturer shall have no tortious or other liability in respect to this ZoneMaster™ Motorized
Adjustable Damper. Ship unit to Suncourt Inc. only after obtaining a Return Goods Authorization (RGA) number. Returns without this RGA number will not be accepted.
Actual product appearance may differ from illustrations. Suncourt reserves the right to modify any or all of its products' features, designs, components and specifications without
notice.
1. Run one wire from either Transformer low voltage
terminal to either terminal on the Damper.
2. Run one wire from the other Transformer low voltage
terminal to the terminal marked “R” on the thermostat.
3. Run one wire from the other terminal on the Damper
to the terminal marked “W” on the thermostat.
4. Connect the terminals “W” and “Y” on the thermostat
together with a short piece of wire (jumper).
5.
Screw the thermostat to the wall.
6. Plug in Transformer to a properly grounded
110/120V receptical.
THE LOW-VOLTAGE WIRING IS NOT POLARITY SENSITIVE. CONNECT EITHER SCREW ON TERMINAL BLOCK TO EITHER SCREW ON TRANSFORMER.
THE THERMOSTAT OR LOW-VOLTAGE SWITCHING DEVICE CAN BE INSERTED ON EITHER SIDE.
UP TO TWO DAMPERS CAN BE POWERED BY EACH TRANSFORMER BY EITHER WIRING BOTH DAMPERS IN PARALLEL TO THE TRANSFORMER TERMINALS,
OR WIRING THE SECOND DAMPER IN PARALLEL TO THE FIRST DAMPER’S TERMINALS.
WIRING INSTRUCTIONS FOR ZONEMASTER™ DAMPERS - USING A DEDICATED LOW-VOLTAGE THERMOSTAT. DO NOT PLUG TRANSFORMER IN UNTIL
ALL WIRE CONNECTIONS ARE MADE.
INSTRUCTIONS FOR ZONEMASTER™ DAMPERS - USING A 110/120V SWITCH OR TIMER
Plug Transformer into a grounded 110/120V receptical that is operated by a 110/120V wall switch or timer.
HEAT/COOL THERMOSTAT
OR OTHER SWITCHING DEVICE
24 VAC / 20 VA
PLUG-IN TRANSFORMER
DAMPER UNIT
TERMINAL
DEDICATED 24V
THERMOSTAT. NOT YOUR
EXISTING HVAC
SYSTEM THERMOSTAT.
NOT ALL THERMOSTATS
REQUIRE A WIRE TO THE
COMMON TERMINAL.
WY
CR