Manual

11 of 12
Grozone SCC1 Advanced User Guide March 2012 www.grozonecontrol.com
CHANGING THE OUTPUT CONTROL PARAMETER
Turn the SELECT knob (Day Temperature) to position 2. The two top PARAMETER indicators will lit.
CLICK the Pushbutton to select the VALUE Indicator (A to F) you need to turn ON (Lit) or OFF.
Rotate the SET/RESET knob (Humidity Temperature) to turn ON/OFF the selected indicator (selected
indicator is flashing; flashing will stop once value has been set or reset).
To EXIT and SAVE, make sure to move through all 6 indicators. Successful saving will blink the VALUE
indicators 4 times.
Indicator Name
Effect on Settings
(Factory Setting in Bold)
Indicator Name
Effect on Settings
(Indicator OFF is Factory Setting)
COOL
Control Range
Indicator is Off : +/- 2°F around setpoint
Indicator is Lit : +/- 4°F around setpoint
HEAT
Control Range
Indicator is Off :
Fixed range, -8°F to -2°F below setpoint
Indicator is Lit:
Auto range, -8°F to -2°F OR -12°F to -6°F below
setpoint to avoid competing equipment to operate
simultaneously
HUMIDITY
Control Range
Indicator is Off : +/- 2% around setpoint
Indicator is Lit : +/- 4% around setpoint
CO2
Control Range
Indicator is Off : +0 / - 200 ppm below setpoint
Indicator is Lit : +0 / - 400 ppm below setpoint
Low Temp
Limit
Indicator is Off : -6°F below setpoint
Indicator is Lit : -10°F below setpoint
High Temp
Limit
Indicator is Off : +10°F above setpoint
Indicator is Lit : 90°F regardless of setpoint
Ex. COOL, HUMIDITY and CO2 Control Ranges have been set to alternate settings.