USER GUIDE TP1 Temp-1 Day & Night Thermostat Rev. 3.0 www.grozonecontrol.com www.grozonecontrol.
TABLE OF CONTENTS SAFETY NOTICE SAFETY NOTICE ................................................................................. 1 INSTALLATION & OPERATION............................................................ 2 OPTIONAL SETTINGS/HEATING ......................................................... 3 OPTIONAL SETTINGS/COOLING ......................................................... 4 QUICK TROUBLESHOOTING GUIDE .................................................... 5 COMPLETE TROUBLESHOOTING GUIDE........
INSTALLATION & OPERATION OPTIONAL SETTINGS/HEATING Note: This unit has been set to perform in Cooling Mode. For Heating Mode, refer to Optional Settings. Change to Heating Mode Set Values A. Unplug the unit Set both values to minimum Light sensor (photocell) Day Temp Night Temp B. Within 5 seconds, plug in the unit and set both values to maximum Plug into 120 VAC outlet C.
OPTIONAL SETTINGS/COOLING PLUG UNIT INTO 120V QUICK TROUBLESHOOTING CHART Product Model: TP1 PLUG LOAD INTO OUTPUT Change to Cooling Mode Min : (55°F) Max : (95°F) A. Unplug the unit Set both values to maximum Product Defective Output Off Day knob to Max Night Knob to Min Output Off Output On B. Within 5 seconds, plug in the unit and set both values to minimum After 10 sec Output On Product Defective C.
COMPLETE TROUBLESHOOTING GUIDE Day & Night Thermostat TP1 1 – Before you start ***IMPORTANT: READ AND FOLLOW THESE INSTRUCTIONS BEFORE STARTING THE TEST. COMPLETE TROUBLESHOOTING GUIDE STEP HANDLING AND TEST DESCRIPTION EXPECTED RESULTS • Keep the Light Sensor fully covered while turning the LOWER KNOB fully CW Output On indicator will turn OFF again. 5 • Uncover the Light Sensor and wait 6 to 8 sec.
WARRANTY & CUSTOMER SERVICE DO YOU HAVE A PROBLEM WITH YOUR GROZONE CONTROLLER ? PLEASE READ THESE INSTRUCTIONS CAREFULLY AND SAVE THEM FOR FUTURE REFERENCE 1. I think my controller is damaged, or it simply does not work as indicated in the user guide, what should I do ? ◊ Please refer to the troubleshooting steps. Follow these instructions carefully, step by step. The Controller should work as described in the “Expected Result” column of the Complete Troubleshooting Guide on page 6-7.
PRODUCT DETAILS Operation and Specifications Temperature setpoint between 55°F and 95°F / 13°C to 35°C. Fixed differential of ± 2°F Example: Operating mode: cooling, setpoint: 75°F so the output turns ON at 77°F and turns OFF at 73°F 6-ft temperature probe works from +32°F at +212°F (0°C to 100°C). Electrical Specifications: See the rating label on your product.