Baery Charger
The external charger has been designed to charge two 12V
Gel type baeries connected in series (= 24 V).
The chargers have features which prevent hazards or
accidents occurring as a result of connecng baeries the
wrong way round, overheang caused by fault condions or
aempng to charge wrong voltage baeries.
The majority of charger sizes are electrically double
insulated and no earth connecon is required. Some larger
sizes may be electrically earthed and this will be clearly
stated on the label.
If your charger has been specied for use in Connental
Europe it will contain a European two pin plug which does
not have a fuse. In this case the fuse is located in the fascia
panel of the charger.
Country specic informaon: UK
The 3 pin UK mains input plug contains a replaceable fuse.
The rang of this fuse is shown on the charger label.
DANGER!
As with all mains powered electrical equipment, always
replace blown fuses with the same type and size of fuse as
specied.
Fing of dierent fuses can result in an increased re risk,
damage to the charger or failure of the charger to operate
properly.
6.3 The range of your vehicle:
Please refer to the specicaon tables at the back of this
manual for Energy Consumpon, (Maximum Range),
informaon.
Most manufacturers of mobility products state the range of
their vehicles either in the sales literature or within the Owners
Manual. The range stated somemes diers from manufacturer
to manufacturer even though the baery size is the same.
Sunrise Medical measure the range of their vehicles in a
consistent and uniform manner, but variances sll occur due to
motor eciencies and overall product load weight.
The range gures are calculated to I.S.O. Standard 7176. Part 4:
Wheelchair Energy Consumpon Theorecal Range.
This test is carried out in controlled condions with new, fully
charged baeries, on a level test surface and a user weight of
100 kg. The range gures stated should be seen as a theorecal
maximum and could be reduced if any single, or combinaon, of
the following circumstances occur:
User weight heavier than 100 kg.
Baeries whose age and condion are less than perfect.
The terrain is dicult e.g. very hilly, sloping, muddy ground,
gravel, grass, snow and ice.
The vehicle climbs kerbs regularly.
The ambient temperature is very hot or very cold.
Incorrect tyre pressures in one or more tyres.
Lots of start/stop driving.
Also thick pile carpets within the home can aect range.
Use of addional power consumpon opons (e.g. light,
actuators, etc.)
The baery sizes available on each Sunrise Medical product
should give sucient range to cope with the majority of
customer’s lifestyles.