Warranty

117
Universal ThermostatsUniversal Thermostats
Universal ThermostatsUniversal Thermostats
Universal Thermostats
General Purpose L & LD Series
• Open on rise
• Close when temperature differential is reached
• 1/4" quick disconnect terminals
• Use 60T Electrical Ratings
Applications
• Most home laundry dryers
• Fan and Limit Applications
UL RECOGNIZED
“L” Series,
Single Pole - Single Throw
36T Electrical Ratings
Motor Rating
Resistive (Inductive) Pilot
VAC (Non-Inductive) Full Load Locked Rotor Duty
120 15A 3A 12A 125 VA
240 1OA 1.5A 6A 125 VA
350°F Max Ambient Temperature
60T Electrical Ratings
Motor Rating
Resistive (Inductive) Pilot
VAC (Non-Inductive) Full Load Locked Rotor Duty
120 25.OA 14.OA 72.OA 125 VA
240 25.OA 10.OA 60.OA 125 VA
350°F Max Ambient Temperature
Typical Electrical Ratings
Supco
No. °Diff. Open (°F) Close (°F)
L120 10 120 110
L125 10 125 115
L130 15 130 115
L135 15 135 120
L140 20 140 120
L145 20 145 125
L150 20 150 130
L155 20 155 135
L160 20 160 140
L165 20 165 145
L170 20 170 150
L175 20 175 155
L180-20 20 180 160
L180-40 40 180 140
L190 40 190 150
L200 40 200 160
L205 40 205 165
L225 40 225 185
L240 40 240 200
L250 40 250 210
L260 40 260 220
L270 40 270 230
L290 40 290 250
L300 40 300 260
L320 40 320 280
L340 40 340 300
Supco No. Cut Out °F Cut In °F Differential °F
LD120 120 105 15
LD130 130 115 15
LD135 135 120 15
LD140 140 120 20
LD145 145 125 20
LD155 155 135 20
LD170 170 150 20
LD190 190 170 20
LD200 200 160 40
LD210 210 170 40
LD225 225 185 40
LD240 240 200 40
LD270 270 230 40
LD290 290 250 40
LD305 305 265 40