Warranty

151
Infrared Thermometers
Laser Infrared Thermometers offer precise, non-contact measurement in a
lightweight, hand held instrument. With one hand operation, they are ideal
for a wide variety of applications.
PIT1
• 1:1 Optical Ratio
• Pocket Size
• Min/Max Measurements
LIT6
• 6:1 Optical Ratio
• Laser Pointer
• Backlight
LIT8B
• 8:1 Optical Ratio
• Laser Pointer
• Trigger Style
• Backlight
LIT50
• 50:1 Optical Ratio
• Laser Pointer
• High & Low Temperature Range
• Backlight
• Carrying Case Included
LIT11TC
11:1 Optical Ratio
• Laser Pointer
• High & Low Temperature Range
• Backlight
• Carrying Case Included
• K-Type Thermocouple (probe included)
- Temperature Range 58°F to 482°F
(14°C to 250°C)
Full range:
-83.2°F to 1999°F
(-64°C to 1400°C)
- Temperature Accuracy +/- 1% of reading or 2°F
• Circuit Breaker Panels
• Motors/Bearings
• Transformers
Applications
• Refrigeration Systems
• Heating Systems
• Supply and Return Registers
MetersMeters
MetersMeters
Meters
PIT1 LIT6 LIT8B LIT11TC LIT50
Optical Ratio 1:1 6:1 8:1 11:1 50:1
Temperature Range -27°F to +428°F 0°F to +500°F -4°F to 518°F -76 °F to 932°F -58°F to 1832°F
(-33°C to +220°C) (-18°C to +260°C) (-20°C to 270°C) (-60°C to 500°C) (-50°C to 1000°C)
Best Resolution 0.1°C or °F 1°F (1°C) 1°F (1°C) 0.1°F 0.1°F
Accuracy +2% of reading or +2% of reading or +2% of reading or +/- 2°F +/- 2% of reading or
+2°C +2°C +4°F (2°C) (+/- 1°C) +4°F (2°C)
Emissivity 0.95 adjustable 0.95 fixed 0.95 fixed 0.95 adjustable 0.95 fixed
Automatic shut off Yes Yes Yes Yes Yes
Power Supply CR2032 9V Battery 9V Battery 2 AA Batteries 9 V Battery
(Included) (Not Included) (Included) (Included) (Included)
Weight 1.3 oz. (32g) 5.3 oz. (150g) 5.8 oz. (180g) 6.3 oz. (179g) 10.23 oz. (290g)
Dimensions .7" X 1.5" X 2.7" 5.1” X 2” X 1.25” 6.4" X 3.2" X 2.4" 6.9” X 1.5” X 2.8” 3.94” X 2.2” X 9.06”
(18mm X 37mm X 68mm) (18mm X 50mm X 42mm) (159mm X 79mm X 57mm) (175 X 39 X 71mm) (100 X 56 X 230 mm)
Emissivity:
The ability of a surface to reflect the infrared radiation relative to an ideal
surface. A flat black surface is as close to ideal as you can get. Most
infrared thermometers have a fixed emissivity of .95. The more reflective
the surface the lower the emissivity adjustment should be.
NEW
Application Note:
What is Distance to Spot Ratio (D:S)?
This is the size of the measurement field that a non-contact infrared
thermometer uses to provide a temperature reading. The infrared
thermometer averages the temperature of that field to calculate the
temperature reading. For example, a D:S ratio of 8:1 means that the
measurement field measures approximately 1 foot in diameter when
the target is approximately 8 feet away.
• Ducts
• And More
Infrared Specifications