All of your temperature sensitive areas are protected with the broadest line of temperature alarms: single and dual set point, wireless remote, battery
operated and multi-channel. Select the right one for your application.
Features/Benefits
• Adjustable alarm temperature ranges
• Audible and visual alarm
• Built-in terminals for remote alarm or
telephone dialer connection (except TA7)
• Alarm switch for ‘No delay’ or ‘1 hour delay’
TA6 Dual Set Point Temperature Alarm
Alarms on a rise AND fall in temperature.
• Adjustable Range from -10°F to +80°F (-25°C to +30°C)
TA Series Temperature Alarms
TA7
Battery Operated Temperature Alarm
For sensitive temperature applications in remote areas,
this battery operated unit is inexpensive and easy to install.
Alarms on rise in temperature only.
• Adjustable Range from -10°F to +80°F (-25°C to +30°C)
Applications
• Food Markets, Convenience Stores, Supermarkets
• Restaurants, Florists, Greenhouses
• Laboratories, Phamaceutical Srorage Facilities
• Refrigerated Transport, Cold Storage Facilities
• Computer
TA2 Single Set Point Temperature Alarm
A reliable, inexpensive alarm for refrigerators and freezers.
Just flip a switch to activate alarm on a rise or fall in temperature.
• Adjustable Range from -10°F to +80°F (-25°C to +30°C)
MODEL NO.
TA6 120 VAC Fahrenheit Model
TA6C 120 VAC Celsius Model
TA6220 220 VAC Fahrenheit Model
TA6C220 220 VAC Celsius Model
Temperature Alarm Specifications
TA2 TA6 TA7
Alarm Channels 1 2 1
Alarm Adjustment Range -10°F to 80°F -10°F to 80°F -10°F to 80°F
(-25°C to 30°C, Celsius model) (-25°C to 30°C, Celsius model) (-25°C to 30°C, Celsius model)
Probe Encapsulated sensor with 6 ft. cord Encapsulated sensor with 15 ft. cord Encapsulated sensor with 6 ft. cord
Sensor Type Thermistor Thermistor Thermistor
Maximum Probe extension 200 ft. 200 ft. 100 ft.
Temperature Accuracy (Display) ±2°F at 75°F ambient
Remote Alarm Connections Screw type, 120 VAC, Screw type 120 VAC, None
5 Amps (dry contacts) 5 Amp max., (dry contacts)
Power 120 V AC (220 V optional) 120 V AC (220 V optional) 9 V alkaline battery (not included)
Case Hi-impact thermoplastic Hi-impact thermoplastic Hi-impact thermoplastic
Mounting Surface, external holes provided Surface, external holes provided Surface, adhesive pads/keyhole slot
Dimensions 3" x 4 7/8" x 1 5/8" 3" x 4 7/8" x 1 5/8" 5 3/4" x 1 1/2" x 1"
Weight 13 oz 13 oz 5 oz
Warranty 1 year 1 year 1 year
Temperature Alarm Accessories
TA2 TAL2 TA4 TA6 TA7 TA3 TAP4
SW25 25’ Extension Wire * * * * *
SW50 50’ Extension Wire * * * * *
SW75 75’ Extension Wire * * * * *
SW100 100’ Extension Wire * * * * *
TCW25 25’ Type J Thermocouple Wire * *
TCW50 50’ Type J Thermocouple Wire * *
TCW75 75’ Type J Thermocouple Wire * *
TCW100 100’ Type J Thermocouple Wire * *
TA3P Probe w/ 6’ Type J Thermocouple Wire *
TA4P Probe w/ 6’ Type J Thermocouple Wire *
Temperature Alarm Accessories
TA2 TAL2 TA4 TA6 TA7 TA3 TAP4
TA2PROBE Probe w/ 6’ extension wire *
TA6PROBE Probe w/ 6’ extension wire *
TA7PROBE Probe w/ 4’ extension wire *
14265 Replacement Sensor * *
USBS USB to Serial Interface *
13495 Serial Port Cable *
ADTA Auto Dialer * * * * * *
MODEL NO.
TA7 Fahrenheit Model
TA7C Celsius Model
MODEL NO.
TA2 120 VAC Fahrenheit Model
TA2C 120 VAC Celsius Model
TA2-220 220 VAC Fahrenheit Model
TA2-220C 220 VAC Celsius Model