Warranty

POWER PILOT
CONTACT 208/240V 208/240V
RATINGS 120V 277V 120V 277V
Full Load Amps 12 6 - -
Resistive Amps* 15 15 3 3
Locked Rotor Amps 60 35 - -
Horsepower 3/4 3/4 1/10 1/10
63
*0.75 power factor
RelaysRelays
RelaysRelays
Relays
Replacing all potential relays, these WIRE TO WIRE Universal Potential Relays offer the ultimate in convenience. One potential relay to fit any application.
Choose to “drop in” the SUPR Universal Potential Relay or “dial in” the exact pick-up voltage for the APR5 Adjustable Potential Relay. State of the Art
electronic circuitry provides Wire to Wire replacement of any potential relay with added motor protection.
Features/Benefits
• Reduces inventory
• Wire to Wire Replacement for virtually
ALL potential relays.
• Recycles instantly
Universal Potential Relays
SUPR Universal Potential Relay
• Time Function Relay
• Start Time: 1.0 - 0.5 seconds
APR5 Adjustable Potential Relay
• Adjustable, Voltage Sensitive Relay
• Set pick-up voltage
• Safety time out 1.0 – 1.5 seconds
Common Specifications
Operating Voltage 110 – 270 VAC, Single Phase
Amperage 30 AMP
Motor Power Rating up to 5 hp
Operating Position Non-positional mounting.
Universal Mounting Allows for easy installation. Unused portions
Bracket of the bracket simply snap off with pliers.
Terminals Screw or push-on. Adapters to convert
screw-on to push-on are provided.
Dimensions 1.75W x 2.25L x 1.50H
90X Series Potential Relays
• Meets all requirements of
OEM relays
• Universal break-off
bracket
Features/Benefits
• 50/60 cycle
• Contact rating 35 amp
@ 277 VAC
• Non-positional
• Instructions and wiring
diagram included in each
relay
®
903X Series General
Purpose Switching Relays
Double pole – double throw (DPDT)
Applications
• HVAC/ R
• Appliance vending machines
• Fan controls
• Business machines
PART COIL TERMINAL TERMINAL CROSS REFERENCE
NO. VOLTAGE 1-2-3 4-5-6 ESSEX/RBM HONEYWELL
90340 24 power power 90-340 R8222D1014
90341 110/12 power power 90-341 R4222D1013
90342 208/240 power power 90-342 R4222N1021
CONTINUOUS
PART COIL PICK-UP DROP OUT REPLACES GE 3ARR3
NO. VOLTAGE MIN. MAX. MAX. RELAY GROUPS*
9063 170 139 153 55 2J; 2K; 2L; 2M; 5N; 7J; 7K; 7L; 7M; 7N; 8L;
8M; 8N
9064 395 260 275 120 3A; 3B; 3AV; 3AU; 4A; 4B; 6A; 6B; 6AV; 10A;
10B; 10AU; 10AV; 14A; 14B; 16A
9065 332 168 182 90 3P; 3R; 3AP; 5P; 5R; 5S; 5T; 13P; 19N; 22S
9066 395 215 225 120 3U; 3V; 3AT; 6U; 6V; 6W; 16U
9067 420 295 315 125 3C; 3D; 3AA; 4C; 4D; 4BK; 6C; 6D; 6AA; 10C;
10D; 26A; 26B; 26C; 26D
9068 502 325 345 135 3E; 3F; 3AB; 3AC; 4E; 4F; 4G; 6E; 6F; 6G; 10H;
10AB; 10AC; 26E; 26F; 26G; 26H; 27E; 27F; 27G
9069 336 180 195 105 3S; 3T; 10S; 10T; 10AS; 13S; 13T; 20S; 25S; 25T
9070 253 285 305 77 5B; 5C; 5D; 5AA; 8B; 8C; 8D; 27A; 27B; 27C
9071 420 212 232 121 6TV; 6TW; 10V; 16TV; 20V
• Accomodates screw-on or push-on connections.
• Dimensions identical to industry standard potential relays.
• Easy replacement mounting with universal mounting bracket.
• Start winding protection if motor does not start.
• Prevents start capacitor venting when motor doesn’t start.
®
Note: See Technical Area for Application Note on Relays
Applications
• Replaces all OEM potential relays
• Used on any single phase motor or
air conditioning and refrigeration
compressor up to 5 hp.