Manual

IMPORTANT INFORMATION
Theminimuminletgassupplypressureis5.5incheswatercolumnfornaturalgasand11.0inches
watercolumnforpropane.Themaximumallowableinletgassupplypressureis10.5incheswater
columnfornaturalgasand13.0incheswatercolumnforpropane.If this appliance is to be supplied
withL.P.gasthetankorbottlesupplyingthegasmusthavearegulatorthatreducesgaspressure
between11and13incheswatercolumn.
WARNING: Thisappliancemustbeisolatedfromthegassupplypipingsystembyclosingits
individual manual shutoff valve during any pressure testing of the gas supply piping
systemattestpressuresequaltoorlessthan1/2PSIG.
Theapplianceanditsindividualshutoffvalvemustbedisconnectedfromthegassupply
pipingsystemduringpressuretestingofthatsystemattestpressuresinexcessof
1/2PSIG.
BTU INFORMATION
Set Natural Gas L.P. Gas
24” 60,000BTUs 60,000BTUs
INSTALLATION TO EXISTING GAS LINE IN FIREPLACE
AmanualON/OFFvalveshouldbepresentwithineasyreachoftheGaslogset.Ifamanualvalveis
notpresent,onemustbeinstalledpriortothegasloginstallation.
INSTALLATION IN A MASONRY FIREPLACE
A1/2”gassupplylinemustbeprovidedtothereplace.Mostinstallationsrequiredrillinganaccess
holethroughtheMasonrywall.Thesupplylineshouldbesecuredandsealedbymortarwithinthe
accesshole.ThesupplylineshouldalsohaveanON/OFFvalveinthewallorinsidethereplace.
DAMPER CLAMP INSTALLATION
Thisapplianceisonlytobeinstalledandburnedinafullyventedreplacewithafullyfunctional
damperandchimneythatisfreeofanyobstructions.Adamperclampisprovidedtoallowanypilot
combustionproductstovent.Theunitmustbeoperatedwiththedamperinthefullyopenedposition.
(SeeFigure1).
PREFABRICATED
FIREPLACE
MASONRY
FIREPLACE
Figure 1: Damper Stop Clamp
Page 4